IEEE C62 92 6-2017 en Guide for Application of Neutral Grounding in Electrical Utility Systems Part VI-Systems Supplied by Current-Regulated Sources.pdf
《IEEE C62 92 6-2017 en Guide for Application of Neutral Grounding in Electrical Utility Systems Part VI-Systems Supplied by Current-Regulated Sources.pdf》由会员分享,可在线阅读,更多相关《IEEE C62 92 6-2017 en Guide for Application of Neutral Grounding in Electrical Utility Systems Part VI-Systems Supplied by Current-Regulated Sources.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Guide for Application of Neutral Grounding in Electrical Utility Systems, Part VISystems Supplied by Current-Regulated SourcesIEEE Std C62.92.6-2017IEEE Power and Energy SocietySponsored by theSurge Protective Devices CommitteeIEEE3 Park AvenueNew York, NY 10016-5997USA,(6WG i.e., their relativ
2、e phase angle difference is zero. The unfaulted phase voltage, assuming constant current magnitude is maintained, is therefore 3 Isource Zy. Thus, if the pre-fault source power output exceeds one-third of the delta-connected load demand, a ground-fault overvoltage will occur. If the output substanti
3、ally exceeds this threshold, one or more sources may reach its output voltage ceiling. Ideally, unfaulted phase voltage will be limited to this ceiling. This voltage is directly detectable at the source, and protective functions will tend to limit the magnitude and duration of overvoltage.In most pr
4、actical distribution situations, where single-phase inverters dominate, the majority of load will be connected phase to ground.10. Some load, however, may be connected phase-to-phase or in an ungrounded-wye confi guration (e.g., three-phase motor windings). In this situation, the ground-fault overvo
5、ltage is approximately Isource Zeqwhere Zeqis calculated based on the sum of the phase-to-ground connected load demand plus one-third of the ungrounded load demand.Some three-phase inverters are composed of three physically-independent single-phase inverters. If these inverters have controls to main
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC629262017ENGUIDEFORAPPLICATIONOFNEUTRALGROUNDINGINELECTRICALUTILITYSYSTEMSPARTVISYSTEMSSUPPLIEDBYCURRENTREGULATEDSOURCESPDF

链接地址:http://www.mydoc123.com/p-1249279.html