IEEE C57 12 36-2017 en Standard Requirements for Liquid-Immersed Distribution Substation Transformers《液浸式配电变压器要求》.pdf
《IEEE C57 12 36-2017 en Standard Requirements for Liquid-Immersed Distribution Substation Transformers《液浸式配电变压器要求》.pdf》由会员分享,可在线阅读,更多相关《IEEE C57 12 36-2017 en Standard Requirements for Liquid-Immersed Distribution Substation Transformers《液浸式配电变压器要求》.pdf(39页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Standard Requirements for Liquid-Immersed Distribution Substation Transformers IEEE Std C57.12.36-2017 (Revision of IEEE Std C57.12.36-2007) IEEE Power and Energy Society Sponsored by the Transformers Committee IEEE 3 Park Avenue New York, NY 10016-5997 USAIEEE Std C57.12.36-2017 (Revision of I
2、EEE Std C57.12.36-2007) IEEE Standard Requirements for Liquid-Immersed Distribution Substation Transformers Sponsor Transformers Committee of the IEEE Power and Energy Society Approved 15 June 2017 IEEE-SA Standards BoardAbstract: Small power transformers have become a significant element in distrib
3、ution systems supplying large commercial customers like major resort hotels and site-specific industrial custom- ers that desire the local utility to own, operate, and maintain the serving transformer. These trans- formers can range in sizes from 112.5 kVA to 10 000 kVA with primary voltages at 69 0
4、00 V and below and secondary voltages from 34 500 V to 120 V. Transformers in this standard are generally for larger distribution customers often with special voltages or installation requirements like con- vention centers with large chiller plants and extensive exhibit space. There is often a desir
5、e to serve these transformers from underground systems using side-mounted bushings on the primary. This standard seeks to define the small power transformer that is applied as more than just a lim- ited-scope version of the power transformers covered by IEEE Std C57.12.10 and as more than a large di
6、stribution-class transformer covered by IEEE Std C57.12.34. Keywords: class I, distribution substation transformer, IEEE C57.12.36, liquid-immersed, station type, transformer, unit substation The Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue, New York, NY 10016-5997, USA Copy
7、right 2017 by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 31 August 2017. Printed in the United States of America. IEEE is a registered trademark in the U.S. Patent fitness for a particular purpose; non-infringement; and quality, accuracy, effectiveness
8、, currency, or completeness of material. In addition, IEEE disclaims any and all conditions relating to: results; and workmanlike effort. IEEE standards documents are supplied “AS IS” and “WITH ALL FAULTS.” Use of an IEEE standard is wholly voluntary. The existence of an IEEE standard does not imply
9、 that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to change brought about through developments in the
10、state of the art and comments received from users of the standard. In publishing and making its standards available, IEEE is not suggesting or rendering professional or other services for, or on behalf of, any person or entity nor is IEEE undertaking to perform any duty owed by any other person or e
11、ntity to another. Any person utilizing any IEEE Standards document, should rely upon his or her own independent judgment in the exercise of reasonable care in any given circumstances or, as appropri- ate, seek the advice of a competent professional in determining the appropriateness of a given IEEE
12、standard. IN NO EVENT SHALL IEEE BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY , OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO: PROCURE- MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF L
13、IABILITY , WHETHER IN CON- TRACT, STRICT LIABILITY , OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE PUBLICATION, USE OF, OR RELIANCE UPON ANY STANDARD, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE AND REGARDLESS OF WHETHER SUCH DAMAGE WAS FORESEEABLE.4 Copyright 2017
14、IEEE. All rights reserved. Translations The IEEE consensus development process involves the review of documents in English only. In the event that an IEEE standard is translated, only the English version published by IEEE should be considered the approved IEEE standard. Official statements A stateme
15、nt, written or oral, that is not processed in accordance with the IEEE-SA Standards Board Operations Manual shall not be considered or inferred to be the official position of IEEE or any of its committees and shall not be considered to be, or be relied upon as, a formal position of IEEE. At lectures
16、, symposia, seminars, or educational courses, an individual presenting information on IEEE standards shall make it clear that his or her views should be considered the personal views of that individual rather than the formal position of IEEE. Comments on standards Comments for revision of IEEE Stand
17、ards documents are welcome from any interested party, regardless of membership affiliation with IEEE. However, IEEE does not provide consulting information or advice pertain- ing to IEEE Standards documents. Suggestions for changes in documents should be in the form of a proposed change of text, tog
18、ether with appropriate supporting comments. Since IEEE standards represent a consensus of concerned interests, it is important that any responses to comments and questions also receive the concur- rence of a balance of interests. For this reason, IEEE and the members of its societies and Standards C
19、oordi- nating Committees are not able to provide an instant response to comments or questions except in those cases where the matter has previously been addressed. For the same reason, IEEE does not respond to interpretation requests. Any person who would like to participate in revisions to an IEEE
20、standard is welcome to join the relevant IEEE working group. Comments on standards should be submitted to the following address: Secretary, IEEE-SA Standards Board 445 Hoes Lane Piscataway, NJ 08854 USA Laws and regulations Users of IEEE Standards documents should consult all applicable laws and reg
21、ulations. Compliance with the provisions of any IEEE Standards document does not imply compliance to any applicable regulatory require- ments. Implementers of the standard are responsible for observing or referring to the applicable regulatory requirements. IEEE does not, by the publication of its s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC5712362017ENSTANDARDREQUIREMENTSFORLIQUIDIMMERSEDDISTRIBUTIONSUBSTATIONTRANSFORMERS 液浸式 配电 变压器 要求

链接地址:http://www.mydoc123.com/p-1249175.html