IEEE C37 04 INT 1-2010 en Rating Structure for AC High-Voltage Circuit Breakers《IEEE Std C37 04 -1999 IEEE Std C37 06 -2000和IEEE Std C37 09 -1999的IEEE标准解释文件》.pdf
《IEEE C37 04 INT 1-2010 en Rating Structure for AC High-Voltage Circuit Breakers《IEEE Std C37 04 -1999 IEEE Std C37 06 -2000和IEEE Std C37 09 -1999的IEEE标准解释文件》.pdf》由会员分享,可在线阅读,更多相关《IEEE C37 04 INT 1-2010 en Rating Structure for AC High-Voltage Circuit Breakers《IEEE Std C37 04 -1999 IEEE Std C37 06 -2000和IEEE Std C37 09 -1999的IEEE标准解释文件》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Standards Interpretations for IEEE Std C37.04 -1999,IEEE Std C37.06-2000,and IEEE Std C37.09-1999 Copyright 2010 by the Institute of Electrical and Electronics Engineers, Inc. Three Park Avenue New York, New York 10016-5997 USA All Rights Reserved. This is an interpretation of IEEE Std C37.04-1
2、999, IEEE Std C37.06-2000, and IEEE Std C37.09-1999. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download and print one copy o
3、f this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standards Department for the appropriate license. Use of the information contained in this document is at your own risk. IEEE Standards Depa
4、rtment Copyrights and Permissions 445 Hoes Lane, P. O. Box 1331 Piscataway, New Jersey 08855-1331, USA July 2010 Interpretation Number 1: Topic: Rated Interrupting Time Interpretation Request #1 Question: What is the applicability of interrupting times determined by 50 Hz testing to applications of
5、the high voltage circuit breaker when applied at 60Hz? Are the interrupting times obtained at 50 Hz converted to a 60 Hz basis or added to the contact parting time raw? Discussion: 1. IEEE Std. C37.04-1999, 5.6 defines the rated interrupting time of a circuit breaker as the maximum permissible inter
6、val between the energizing of the trip circuit at rated control voltage and rated operating pressure for mechanical operation, and the interruption of the current in the main circuit in all poles. In discussing numerical values of interrupting time, IEEE Std C37.04-1999 uses cycles as the unit of me
7、asure and clarifies that cycles are based on corresponding rated power frequency. 2. IEEE /ANSI Std. C37.06-2000, Table 1 provides for the preferred ratings of indoor circuit breakers including the rated interrupting time which is given in milliseconds Page 1 of 3IEEE Std C37.04-1999, C37.06-2000, C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC3704INT12010ENRATINGSTRUCTUREFORACHIGHVOLTAGECIRCUITBREAKERSIEEESTDC37041999IEEESTDC37062000 IEEESTDC37091999

链接地址:http://www.mydoc123.com/p-1249017.html