IEEE C37 010-1999 en Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis《基于平衡电流的额定交流高压断路器应用指南》.pdf
《IEEE C37 010-1999 en Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis《基于平衡电流的额定交流高压断路器应用指南》.pdf》由会员分享,可在线阅读,更多相关《IEEE C37 010-1999 en Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis《基于平衡电流的额定交流高压断路器应用指南》.pdf(81页珍藏版)》请在麦多课文档分享上搜索。
1、The Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USACopyright 2000 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Published 31 May 2000. Printed in the United States of America.Print: ISBN 0-7381-1837-3 SH94796PDF:
2、 ISBN 0-7381-1828-1 SS94796No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise,without the prior written permission of the publisher.IEEE Std C37.010-1999 (R2005)(Revision ofIEEE Std C37.010-1979)IEEE Application Guide for AC High-Voltage Circuit
3、 Breakers Rated on a Symmetrical Current BasisSponsorSwitchgear Committeeof theIEEE Power Engineering SocietyReaffirmed 20 March 2005Approved 16 September 1999IEEE-SA Standards BoardAbstract: This guide covers the application of indoor and outdoor high-voltage circuit breakersrated above 1,000 V for
4、 use in commercial, industrial, and utility installations. It deals with usageunder varied service conditions, temperature conditions affecting continuous currentcompensation, reduced dielectrics, reclosing derating as applicable, calculation of system short-circuit current, compensation at differen
5、t X/R ratios, detailed calculations with application curves,out-of-phase switching, and general application.Keywords: Ambient compensation/emergency operation, capacitor switching, high-voltage circuitbreakers, indoor drawout, line closing, load current switching, outdoor, pollution level creepagedi
6、stance, power frequency, rated maximum voltage, short-circuit consideration, TRV, transformercurrent switching,IEEE Standardsdocuments are developed within the IEEE Societies and the Standards Coordinating Com-mittees of the IEEE Standards Association (IEEE-SA) Standards Board. Members of the commit
7、tees servevoluntarily and without compensation. They are not necessarily members of the Institute. The standardsdeveloped within IEEE represent a consensus of the broad expertise on the subject within the Institute aswell as those activities outside of IEEE that have expressed an interest in partici
8、pating in the development ofthe standard.Use of an IEEE Standard is wholly voluntary. The existence of an IEEE Standard does not imply that thereare no other ways to produce, test, measure, purchase, market, or provide other goods and services related tothe scope of the IEEE Standard. Furthermore, t
9、he viewpoint expressed at the time a standard is approved andissued is subject to change brought about through developments in the state of the art and commentsreceived from users of the standard. Every IEEE Standard is subjected to review at least every five years forrevision or reaffirmation. When
10、 a document is more than five years old and has not been reaffirmed, it is rea-sonable to conclude that its contents, although still of some value, do not wholly reflect the present state ofthe art. Users are cautioned to check to determine that they have the latest edition of any IEEE Standard.Comm
11、ents for revision of IEEE Standards are welcome from any interested party, regardless of membershipaffiliation with IEEE. Suggestions for changes in documents should be in the form of a proposed change oftext, together with appropriate supporting comments.Interpretations: Occasionally questions may
12、arise regarding the meaning of portions of standards as theyrelate to specific applications. When the need for interpretations is brought to the attention of IEEE, theInstitute will initiate action to prepare appropriate responses. Since IEEE Standards represent a consensus ofall concerned interests
13、, it is important to ensure that any interpretation has also received the concurrence of abalance of interests. For this reason, IEEE and the members of its societies and Standards CoordinatingCommittees are not able to provide an instant response to interpretation requests except in those cases whe
14、rethe matter has previously received formal consideration. Comments on standards and requests for interpretations should be addressed to:Secretary, IEEE-SA Standards Board445 Hoes LaneP.O. Box 1331Piscataway, NJ 08855-1331USAIEEE is the sole entity that may authorize the use of certification marks,
15、trademarks, or other designations toindicate compliance with the materials set forth herein.Authorization to photocopy portions of any individual standard for internal or personal use is granted by theInstitute of Electrical and Electronics Engineers, Inc., provided that the appropriate fee is paid
16、to CopyrightClearance Center. To arrange for payment of licensing fee, please contact Copyright Clearance Center, Cus-tomer Service, 222 Rosewood Drive, Danvers, MA 01923 USA; (978) 750-8400. Permission to photocopyportions of any individual standard for educational classroom use can also be obtaine
17、d through the Copy-right Clearance Center.Note: Attention is called to the possibility that implementation of this standard mayrequire use of subject matter covered by patent rights. By publication of this standard,no position is taken with respect to the existence or validity of any patent rights i
18、nconnection therewith. The IEEE shall not be responsible for identifying patents forwhich a license may be required by an IEEE standard or for conducting inquiries intothe legal validity or scope of those patents that are brought to its attention.Copyright 2000 IEEE. All rights reserved.iiiIntroduct
19、ion(This introduction is not part of IEEE Std C37.010-1999, IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on aSymmetrical Current Basis.)This guide is a revision of IEEE Std C37.010-1979 and contains substantive changes due to the efforts of threecoordinated Working Groups on rev
20、ision and coordination of IEEE Std C37.04, IEEE Std C37.09, andIEEE Std C37.010.Although much of the approach of IEEE Std C37.010-1979 has been retained, many editorial changes,significant enhancements, and some fundamental changes have been made.Some of the major issues include Updating to modern i
21、nterruption technologies. Listing of low-temperature concerns. Inclusion of creepage distance material from IEC 60071-2: 19761. Acknowledgment that historic voltage range factor Khas been changed to 1.0 for new circuitbreakers designs, which allows simplification of the rating structure and circuit
22、breaker application.It is recognized that circuit breakers rated in accordance with older standards, having voltage rangefactor Kdiffering from 1.0, are still available and will be in service for many years. If there is a Kfactor, it should be recorded on the circuit breaker nameplate. For circuit b
23、reakers that have avoltage range factor Kdiffering from 1.0, the user should refer to IEEE Std C37.04-1979,IEEE Std C37.06-1987, IEEE Std C37.09-1979, IEEE Std C37.010-1979, or earlier editions of thesame documents for rating, application, and testing information. Recommendations on applying applica
24、tion margins to rated interrupting time. Recognition that “Tripping Delay” is no longer a rating. Permissible tripping delay will be based onthe short-time (closed) current rating of the circuit breaker. Inclusion of reclosing derating factors for air magnetic and oil circuit breakers as stated in 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC370101999ENAPPLICATIONGUIDEFORACHIGHVOLTAGECIRCUITBREAKERSRATEDONASYMMETRICALCURRENTBASIS 基于 平衡

链接地址:http://www.mydoc123.com/p-1249009.html