IEEE 524-2003 en Guide to the Installation of Overhead Transmission Line Conductors《架空传输线路导线的安装指南》.pdf
《IEEE 524-2003 en Guide to the Installation of Overhead Transmission Line Conductors《架空传输线路导线的安装指南》.pdf》由会员分享,可在线阅读,更多相关《IEEE 524-2003 en Guide to the Installation of Overhead Transmission Line Conductors《架空传输线路导线的安装指南》.pdf(149页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Std 524-2003(Revision of IEEE Std 524-1992)IEEE Standards524TMIEEE Guide to the Installation ofOverhead Transmission LineConductorsPublished by The Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USA12 March 2004IEEE Power Engineering SocietySponso
2、red by theTransmission +1 978 750 8400. Permission to photocopy portions of any individual standard for educationalclassroom use can also be obtained through the Copyright Clearance Center.NOTEAttention is called to the possibility that implementation of this standard may require use of subjectmatte
3、r covered by patent rights. By publication of this standard, no position is taken with respect to the exist-ence or validity of any patent rights in connection therewith. The IEEE shall not be responsible for identifyingpatents for which a license may be required by an IEEE standard or for conductin
4、g inquiries into the legal valid-ity or scope of those patents that are brought to its attention.Copyright 2004 IEEE. All rights reserved.iiiIntroduction(This introduction is not part of IEEE Std 524-2003, IEEE Guide to the Installation of Overhead Transmission LineConductors.)This guide provides ge
5、neral recommendations for the selection of methods, equipment, and tools that havebeen found to be practical for the stringing and grounding of overhead transmission line conductors andoverhead groundwires. The following revisions have been made and are intended to improve the usefulnessof the docum
6、ent:a) The IEEE Std 524, Guide to the Installation of Overhead Transmission Line Conductors and thesupplemental IEEE Std 524a, Guide to Grounding During the Installation of Overhead TransmissionLine Conductors have been combined into one document.b) The stringing specification for fiber optic cables
7、 has been expandedc) A clause on All Dielectric Self-Supporting (ADSS) cable has been addedd) SSAC conductor type designation has been changed to the current ACSS designatione) Helicopter installation methods have been expandedf) All units have been changed to conform with IEEE metric policyParticip
8、antsAt the time this standard was revised, the membership of the Task Group of the Working Group on the Con-struction of Overhead Lines of the Towers, Poles, and Conductors Subcommittee, was as follows:Neil Schmidt,ChairThe following members of the balloting committee voted on this standard. Ballote
9、rs may have voted forapproval, disapproval, or abstention. Bill CaulkinsJim L. ClarkDenise FreyPhilip GivensRon MagnusDouglas ProctorLarry SlavinFrank R. Thrash, Jr.James ApplequistAnthony BakerRobert BrattonSales CasalsJames ChristensenMichael ClodfelderF. Leonard ConsalvoTommy CooperNicholas DeSan
10、tisFrank A. DenbrockJ. Frederick DoeringRandall DotsonDale DouglassMarcia EblenRobert EmersonLowell FinkMarcel FortinDenise FreyGeorge GelaPhillip GivensCharles W. GroseRandall GrovesRichard HenselEward Horgan Jr.Magdi IshacGael KennedyHenry KientzRobert KlugeDonald KoonceStephen R. LambertJames Lar
11、keyKeith LindseyGregory LuriOtto LynchFaramarz MaghsoodlouThomas McCaffreyThomas McCarthyGary MichelYakov MotlisAbdul MousaGeorge NilesJohn OlenikRobert OswaldPaulette PayneCarlos PeixotoRobert PetersCraig PonDouglas ProctorPatrick QuinnJerry RedingJoseph RenowdenThomas RozekJames RuggieriLluis Ramo
12、n Bob SaintNeil SchmidtFrank R. Thrash, Jr.Cassio VinhalDaniel WardJames WilsonLuis E. Zambrano S.ivCopyright 2004 IEEE. All rights reserved.The final conditions for approval of this standard were met on 17 October 2003. When the IEEE-SA Stan-dards Board conditionally approved this standard on 11 Se
13、ptember 2003, it had the following membership:Don Wright,ChairHoward M. Frazier,Vice ChairJudith Gorman,Secretary*Member EmeritusAlso included are the following nonvoting IEEE-SA Standards Board liaisons:Alan Cookson, NIST RepresentativeSatish K. Aggarwal, NRC RepresentativeDon MessinaIEEE Standards
14、 Project EditorH. Stephen BergerJoe BruderBob DavisRichard DeBlasioJulian Forster*Toshio FukudaArnold M. GreenspanRaymond HapemanDonald M. HeirmanLaura HitchcockRichard H. HulettAnant JainLowell G. JohnsonJoseph L. Koepfinger*Tom McGeanSteve MillsDaleep C. MohlaWilliam J. MoylanPaul NikolichGary Rob
15、insonMalcolm V. ThadenGeoffrey O. ThompsonDoug ToppingHoward L. WolfmanCopyright 2004 IEEE. All rights reserved.vContents1. Overview11.1 Scope11.2 Purpose.11.3 Application.12. References23. Definitions and cross reference of terminology.23.1 Definitions and terminology for conductor stringing equipm
16、ent23.2 Acronyms.214. Conductor stringing methods.224.1 Slack or layout method224.2 Tension method225. Grounding equipment and methods.235.1 Protective grounding principles.235.2 Protection of personnel235.3 Hazards and electrical concepts.245.4Grounding equipment, methods, and testing.245.5 Transmi
17、ssion line construction grounding systems.346. Communications407. Conductor reels407.1 Reel types.407.2 Reel handling.408. Special requirements for mobile equipment408.1 Reel stand.408.2 Helicopter.418.3 Tensioner bullwheel characteristics.418.4Puller and tensioner operating characteristics438.5 Pil
18、ot line winder operating characteristics.449. Travelers449.1 Sheave diameter.449.2 Configuration of groove.459.3 Bearings.469.4Material and construction. .469.5 Lining.479.6 Electrical characteristics479.7 Bundled configurations479.8 Helicopter travelers48viCopyright 2004 IEEE. All rights reserved.9
19、.9 Uplift rollers and hold-down blocks489.10Traveler suspension.4910. Typical procedures for stringing operations4910.1Pull, tension, anchor, and splicing sites.4910.2Section between snub structures5110.3Conductor splicing.5210.4Stringing procedures5410.5Sagging procedures6010.6Deadending precaution
20、s.6510.7Clipping-in.6510.8Damper installation6610.9Spacer and spacer damper installation.6611. Special conductors.6611.1ACSSsteel supported aluminum conductor.6711.2T-2 Conductortwisted bare conductors6711.3Self-damping conductor (SDC).6911.4Composite overhead groundwire with optical fibers (OPGW)70
21、11.5All-dielectric self supporting fiber cable (ADSS).71Annex A (informative) Bibliography 74Annex B (informative) Electrical theory . 76Annex C (informative) Grounding electrical concepts. 82Annex D (informative) Travelers or snub structure load calculation 96Annex E (informative) Basic analysis fo
22、r clipping offsets and sagging. 98Annex F (informative) Efficiency of travelers during tension stringing . 106Annex G (informative) Recommended bearing pressure on sheave linings. 108Annex H (informative) All aluminum 1350 alloy conductor standard packages . 109Annex I (informative) ACSR conductor s
23、tandard packages. 111Annex J (informative) Drum or reel winding 114Annex K (informative) Drum or reel capacities . 115Annex L (normative) Electric and magnetic field induction computer program presentation with sampleproblems 118Annex M (normative) Source code for the electric field induction progra
24、m (EFINCUC.C) . 124Annex N (normative) Source code for magnetic field induction program (MFINDUC.C) . 134Copyright 2004 IEEE. All rights reserved.1IEEE Guide to the Installation of Overhead Transmission Line Conductors1. Overview1.1 ScopeThis guide provides general recommendations for the selection
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE5242003ENGUIDETOTHEINSTALLATIONOFOVERHEADTRANSMISSIONLINECONDUCTORS 架空 传输 线路 导线 安装 指南 PDF

链接地址:http://www.mydoc123.com/p-1248757.html