ANS 8 14-2004 Use of soluble neutron absorbers in nuclear facilities outside reactors《反应堆外部核设施中可溶性中子吸收剂的使用》.pdf
《ANS 8 14-2004 Use of soluble neutron absorbers in nuclear facilities outside reactors《反应堆外部核设施中可溶性中子吸收剂的使用》.pdf》由会员分享,可在线阅读,更多相关《ANS 8 14-2004 Use of soluble neutron absorbers in nuclear facilities outside reactors《反应堆外部核设施中可溶性中子吸收剂的使用》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/ANS-8.14-2004use of soluble neutronabsorbers in nuclearfacilities outside reactorsANSI/ANS-8.14-2004REAFFIRMED November 16, 2011 ANSI/ANS-8.14-2004 (R2011) This standard has been reviewed and reaffirmed with the recognition that it may reference other standards and documents that may have been
2、superseded or withdrawn. The requirements of this document will be met by using the version of the standards and documents referenced herein. It is the responsibility of the user to review each of the references and to determine whether the use of the original references or more recent versions is a
3、ppropriate for the facility. Variations from the standards and documents referenced in this standard should be evaluated and documented. This standard does not necessarily reflect recent industry initiatives for risk informed decision-making or a graded approach to quality assurance. Users should co
4、nsider the use of these industry initiatives in the application of this standard. ANSI/ANS-8.14-2004American National StandardUse of Soluble NeutronAbsorbers in NuclearFacilities Outside ReactorsSecretariatAmerican Nuclear SocietyPrepared by theAmerican Nuclear SocietyStandards CommitteeWorking Grou
5、p ANS-8.14Published by theAmerican Nuclear Society555 North Kensington AvenueLa Grange Park, Illinois 60526 USAApproved May 25, 2004by theAmerican National Standards Institute, Inc.AmericanNationalStandardDesignation of this document as an American National Standard attests thatthe principles of ope
6、nness and due process have been followed in the approvalprocedure and that a consensus of those directly and materially affected bythe standard has been achieved.This standard was developed under procedures of the Standards Committee ofthe American Nuclear Society; these procedures are accredited by
7、 the Amer-ican National Standards Institute, Inc., as meeting the criteria for AmericanNational Standards. The consensus committee that approved the standardwas balanced to ensure that competent, concerned, and varied interests havehad an opportunity to participate.An American National Standard is i
8、ntended to aid industry, consumers, gov-ernmental agencies, and general interest groups. Its use is entirely voluntary.The existence of an American National Standard, in and of itself, does notpreclude anyone from manufacturing, marketing, purchasing, or using prod-ucts, processes, or procedures not
9、 conforming to the standard.By publication of this standard, the American Nuclear Society does not insureanyone utilizing the standard against liability allegedly arising from or afterits use. The content of this standard reflects acceptable practice at the time ofits approval and publication. Chang
10、es, if any, occurring through developmentsin the state of the art, may be considered at the time that the standard issubjected to periodic review. It may be reaffirmed, revised, or withdrawn atany time in accordance with established procedures. Users of this standardare cautioned to determine the va
11、lidity of copies in their possession and toestablish that they are of the latest issue.The American Nuclear Society accepts no responsibility for interpretations ofthis standard made by any individual or by any ad hoc group of individuals.Requests for interpretation should be sent to the Standards D
12、epartment atSociety Headquarters. Action will be taken to provide appropriate response inaccordance with established procedures that ensure consensus on theinterpretation.Comments on this standard are encouraged and should be sent to SocietyHeadquarters.Published byAmerican Nuclear Society555 North
13、Kensington AvenueLa Grange Park, Illinois 60526 USACopyright 2004 by American Nuclear Society. All rights reserved.Any part of this standard may be quoted. Credit lines should read “Extracted fromAmerican National Standard ANSI0ANS-8.14-2004 with permission of the publisher,the American Nuclear Soci
14、ety.” Reproduction prohibited under copyright conventionunless written permission is granted by the American Nuclear Society.Printed in the United States of AmericaForewordThis foreword is not part of American National Standard “Use of Soluble NeutronAbsorbers in Nuclear Facilities Outside Reactors,
15、” ANSI0ANS-8.14-2004!This standard provides guidance for the use of soluble neutron absorbers forprocess and handling operations in which solutions of neutron absorbers areused for criticality control. This standard supplements the provisions for “Nu-clear Criticality Safety in Operations with Fissi
16、onable Materials Outside Reac-tors,” ANSI0ANS-8.1-1998, in providing more detailed guidance for the use ofsoluble neutron absorbers. Soluble neutron absorbers can be used as a primarymeans of criticality safety control or as defense in depth to provide an additionalsafety margin and as such make the
17、 safety of the system more robust. As withany parameter controlled for criticality safety, and particularly important withsoluble neutron absorbers, one must ensure that the controlled parameter ismaintained within the range that has been shown by experiment or evaluation tomaintain subcriticality.T
18、his standard prepared by Working Group ANS-8.14 was composed of the fol-lowing members:T. A. Reilly Chairman!, Westinghouse Safety Management Solutions, LLCR. D. Carter Past Chairman!, IndividualL. J. Berg, U.S. Nuclear Regulatory CommissionA. S. Garcia, U.S. Department of Energy, IdahoR. A. Knief,
19、XE CorporationR. C. McBroom, U.S. Department of Energy, Oak Ridge Operations OfficeL. M. Montierth, Idaho National Engineering and Environmental LaboratoryJ. A. Morman, Argonne National LaboratoryV. L. Risner, USECS. K. Skiles, NuclearSafety AssociatesR. E. Wilson, U.S. Department of Energy, Rocky F
20、lats Environmental Technology SiteThis standard was prepared under the guidance of Subcommittee 8, FissionableMaterials Outside Reactors, of the American Nuclear Society. Subcommittee 8 atthe time of initial ballot was composed of the following members:T. P. McLaughlin Chairman!, Los Alamos National
21、 LaboratoryJ. A. Schlesser Secretary!, Westinghouse Safety Management Solutions, LLCF. M. Alcorn, IndividualE. D. Clayton, IndividualA. S. Garcia, U.S. Department of Energy, IdahoN. Harris, BNFLC. M. Hopper, Oak Ridge National LaboratoryR. Kiyose, IndividualR. A. Libby, Pacific Northwest National La
22、boratoryD. A. Reed, Oak Ridge National LaboratoryT. A. Reilly, Westinghouse Safety Management Solutions, LLCH. Toffer, Fluor Federal ServicesG. E. Whitesides, IndividualConsensus Committee N16, Nuclear Criticality Safety, was composed of thefollowing members at the time of approval:C. M. Hopper Chai
23、rman!, Oak Ridge National LaboratoryR. A. Knief Vice-Chairman!, XE CorporationG. H. Bidinger, IndividualR. D. Busch, University of New MexicoM. S. Chatterton, U.S. Nuclear Regulatory CommissionH. L. Dodds, Jr., University of TennesseeR. S. Eby, American Institute of Chemical EngineersC. D. Manning,
24、Framatome ANPB. McLeod, Institute of Nuclear Materials ManagementS. P. Murray, Health Physics SocietyiH. C. Paxton, IndividualR. L. Reed, Westinghouse Safety Management Solutions, LLCB. M. Rothleder, U.S. Department of EnergyF. W. Sanders, IndividualD. R. Smith, IndividualR. G. Taylor, IndividualJ.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANS8142004USEOFSOLUBLENEUTRONABSORBERSINNUCLEARFACILITIESOUTSIDEREACTORS 反应堆 外部 设施 可溶性 中子 吸收剂 使用 PDF

链接地址:http://www.mydoc123.com/p-1243033.html