ANSI IEEE C57 124-1991 Recommended Practice for the Detection of Partial Discharge and the Measurement of Apparent Charge in Dry-Type Transformers《干式变压器表观电荷部分放电.pdf
《ANSI IEEE C57 124-1991 Recommended Practice for the Detection of Partial Discharge and the Measurement of Apparent Charge in Dry-Type Transformers《干式变压器表观电荷部分放电.pdf》由会员分享,可在线阅读,更多相关《ANSI IEEE C57 124-1991 Recommended Practice for the Detection of Partial Discharge and the Measurement of Apparent Charge in Dry-Type Transformers《干式变压器表观电荷部分放电.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、 IEEE Std C57.124-1991(R2002)Reconized as anAmerican National Standard (ANSI)IEEE Recommended Practice for the Detection of Partial Discharge and the Measurement of Apparent Charge in Dry-Type TransformersSponsorTransformers Committeeof theIEEE Power Engineering SocietyApproved June 27, 1991Reaffirm
2、ed June 12, 2002Institute of Electrical and Electronics EngineersApproved October 11, 1991Reaffirmed September 19, 1996American National Standards InstituteAbstract: IEEE Std C57.124-1991 covers the detection of partial discharges occurring in the insulation ofdry-type transformers of their componen
3、ts and the measurement of the associated apparent charge at theterminals when alternating test voltage is applied. The wideband method is used. The detection system andcalibrator characteristics are described, and the test procedure is established.Keywords: Apparent charge, corona, cost coil transfo
4、rmers, dry-type transformers, partial discharge,ventilated dry-type transformersThe Institute of Electrical and Electronics Engineers, Inc.345 East 47th Street, New York, NY 10017-2394, USACopyright 1992 byThe Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Published 1992
5、Printed in the United States of AmericaISBN 1-55937-159-5No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without theprior written permission of the publisher.iiIEEE Standards documents are developed within the Technical Committees of the IEE
6、E Societies and the StandardsCoordinating Committees of the IEEE Standards Board. Members of the committees serve voluntarily and withoutcompensation. They are not necessarily members of the Institute. The standards developed within IEEE represent aconsensus of the broad expertise on the subject wit
7、hin the Institute as well as those activities outside of IEEE that haveexpressed an interest in participating in the development of the standard.Use of an IEEE Standard is wholly voluntary. The existence of an IEEE Standard does not imply that there are no otherways to produce, test, measure, purcha
8、se, market, or provide other goods and services related to the scope of the IEEEStandard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to changebrought about through developments in the state of the art and comments received from users of the standard
9、. EveryIEEE Standard is subjected to review at least every five years for revision or reaffirmation. When a document is morethan five years old and has not been reaffirmed, it is reasonable to conclude that its contents, although still of somevalue, do not wholly reflect the present state of the art
10、. Users are cautioned to check to determine that they have thelatest edition of any IEEE Standard.Comments for revision of IEEE Standards are welcome from any interested party, regardless of membership affiliationwith IEEE. Suggestions for changes in documents should be in the form of a proposed cha
11、nge of text, together withappropriate supporting comments.Interpretations: Occasionally questions may arise regarding the meaning of portions of standards as they relate tospecific applications. When the need for interpretations is brought to the attention of IEEE, the Institute will initiateaction
12、to prepare appropriate responses. Since IEEE Standards represent a consensus of all concerned interests, it isimportant to ensure that any interpretation has also received the concurrence of a balance of interests. For this reasonIEEE and the members of its technical committees are not able to provi
13、de an instant response to interpretation requestsexcept in those cases where the matter has previously received formal consideration.Comments on standards and requests for interpretations should be addressed to:Secretary, IEEE Standards Board445 Hoes LaneP.O. Box 1331Piscataway, NJ 08855-1331USAIEEE
14、 Standards documents are adopted by the Institute of Electrical and Electronics Engineers without regard towhether their adoption may involve patents on articles, materials, or processes. Such adoption does not assumeany liability to any patent owner, nor does it assume any obligation whatever to pa
15、rties adopting the standardsdocuments.iiiForeword(This foreword is not a part of IEEE Std C57.124-1991, IEEE Recommended Practice for the Detection of Partial Discharge and theMeasurement of Apparent Charge in Dry-Type Transformers.)This recommended practice for measuring partial discharge of dry-ty
16、pe transformers was conceived for the purpose ofestablishing a standardized method for conducting partial discharge tests of dry-type transformers. The results of thetests may be compared with various transformer designs and manufacturers to establish a partial discharge limit fordry-type transforme
17、rs.This recommended practice follows the format of IEEE Std 454, IEEE Recommended Practice for the Detection andMeasurement of Partial Discharge (Corona) During Dielectric Tests, and IEEE Std C57.113, IEEE Guide for PartialDischarge Measurement in Liquid-Filled Power Transformers and Shunt Reactors.
18、 Sections on current detection werepurposely omitted, as this technique is normally not used for dry-type transformers.There is no recognized definition of “partial discharge-free“”when referring to partial discharge inception voltage orextinction voltage. An arbitrary sensitivity of 10 pC is sugges
19、ted until such time as a more definitive standard isestablished.Various specifications are already written specifying partial discharge-free transformers from 1.1 p.u. operatingvoltage to 2.0 p.u. operating voltage. It is the intent of this recommended practice to encourage manufacturers of dry-type
20、 transformers and users of dry-type transformers to investigate and report the results of factory tests and fieldexperience of partial discharge in dry-type transformers. It is recognized that Paschens Law applies to the partialdischarge intensity and extinction voltage of dry-type transformers. It
21、is conceivable that a dry-type transformer wouldtest partial discharge-free at 1.65 p.u. voltage at room temperature and be barely partial discharge-free at operatingtemperature for a Class 220C. system. This correlation should be verified with field experience and reported.The guide specifies no pa
22、rticular discharge testing instruments and systems. Several commercially available units arebeing used. A measuring system of discreet components readily available has been used for measuring partialdischarge. Most manufacturers laboratories have partial discharge-free HV test sets and oscilloscopes
23、. The onlyadditional components required to complete the detection circuit are a partial discharge-free coupling capacitorcomposed of two 60 kV, .002 mfd capacitors in series, and an inductance composed of a coil of magnet wire.Calibration is accomplished using a calibrated square wave generator and
24、 a calibrated coupling capacitor of .0001 mfd.The following two test procedures are proposed:1) To test partial discharge between the coil and ground, normally accomplished during the applied voltage test.2) The test procedure takes place during the induced voltage test to detect partial discharge w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIEEEC571241991RECOMMENDEDPRACTICEFORTHEDETECTIONOFPARTIALDISCHARGEANDTHEMEASUREMENTOFAPPARENTCHARGEINDRYTYPETRANSFORMERS

链接地址:http://www.mydoc123.com/p-1242456.html