ANSI ALI LADDER A14 8-2013 Safety Requirements for Ladder Accessories.pdf
《ANSI ALI LADDER A14 8-2013 Safety Requirements for Ladder Accessories.pdf》由会员分享,可在线阅读,更多相关《ANSI ALI LADDER A14 8-2013 Safety Requirements for Ladder Accessories.pdf(49页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI-ASC A14.8-2013American National StandardsAmerican National Standard Safety Requirements for Ladder AccessoriesANSI-ASCA14.8-2013American National Standard Safety Requirements for Ladder AccessoriesSecretariatAmerican Ladder Institute Approved May, 2013American National Standards Institute, Inc.
2、Free ladder safety resources are available from the American Ladder Institute at www.laddersafety.org. A Multimedia Training Program provides guidance on safe ladder selection, use and care at www.laddersafetytraining.org.For information on possible errata sheets and other ANSI-ASC A14 Standards ple
3、ase refer to the ALI website located at:www.americanladderinstitute.orgiAn American National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public
4、. The existence of an American National Standard does not in any respect preclude anyone, whether they have approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to
5、periodic review and users are cautioned to obtain the latest editions and errata sheets.The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no persons shall have the right or authority t
6、o issue an interpretation of an American National Standard in the name of the American National Standards Institute.CAUTION NOTICE: This American National Standard may be revised or withdrawn at anytime. The procedures of the American National Standards Institute require that action be taken to reaf
7、firm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute.Published byAmerican Ladder Institute 330 N. Wabas
8、h Avenue, Suite 2000, Chicago, IL 60611Copyright by ANSI Accredited Standards Committee (ASC) A14 All rights reserved.No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.Printed in the United
9、 States of AmericaAmerican National StandardiiForeword(This foreword is not part of the American National Standard A14.8-2013)This standard on Ladder Accessories is one of the many American National Standards prepared under the ANSI Accredited Standards Committee on Safety in Construction, Care, and
10、 Use of Ladders. A14 Subcommittees that report to the A14 Standards committee have developed the following A14 Standards: A14.1 Portable Wood Ladders; A14.2 Portable Metal Ladders; A14.3 Fixed Ladders; A14.4 Job-made Ladders; A14.5 Portable Reinforced Plastic Ladders; A14.7 Mobile Ladder Stands and
11、A14.9 Disappearing Attic Stairways.This standard on Ladder Accessories was prepared under the supervision of the American National Standards A14 Accredited Standards on Safety in Construction, Care, and Use of Portable Ladders.The A14.8 Ladder Accessories sub-committee was first formed in 1990 to de
12、velop a standard that includes the most commonly used and manufactured ladder accessories. The standard was written as a guide to both manufacturers and end users alike to guide them in the proper care, use and selection of these accessories.This first edition of the American National Standard draws
13、 from the work that was done in the existing standards. The standard prescribes both general design requirements and specific design verification test requirements for each type of accessory. The primary intent behind the design verification testing is twofold. One, to test for the strength and inte
14、grity of the accessory itself, and the other to ensure the installed accessory does not have a detrimental effect on the intended performance of the ladder it is installed to. In addition, labeling, marking and instruction requirements are covered in this standard.Suggestions for improvement for the
15、 standard are welcome. They may be sent to American Ladder Institute, 330 N. Wabash Ave., Suite 2000, Chicago, IL 60611. All comments must be sent on the Official Comment Form that can be found on the last page of this document. Each comment must include a rationale.This standard was proposed and ap
16、proved for submittal to ANSI by the American National Standards Committee on Safety in the Construction, Care, and Use of Portable Ladders. Committee approval of the standard does not necessarily imply that all the committee members voted for its approval. At the time it approved this standard, the
17、A14 had the following members:Eric Knox, ChairmanDave Plotner, Vice ChairJanet Rapp, SecretariatiiiOrganization Represented Name of RepresentativeAmerican Insurance Association George EarhartAmerican Ladder Institute Ron SchwartzMarc McConnell (Alt)American Society of Safety Engineers Michael Lorenz
18、oAssociated General Contractors of America .Charles E. BirdCanadian Standards Association . Oreste SimonettaCosco Home and Office Products Eric KruseTerry Emerson (Alt)Featherlite Industries Garry Turgeon Wolfgang Gelhard (Alt)Illinois Association of Building Maintenance Contractors .Carl Pedersen J
19、ames Weil (Alt)International Brotherhood of Electrical Workers James TomaseskiInternational Brotherhood of Painters and Allied Trades .Greg RenneDan Penski (Alt)International Union of Bricklayers first, with the leveler set at maximum adjustment (maximum difference in height between the side rails o
20、f the ladder) and second, with the legs on a level surface (see Figure 8). When testing on a surface requiring maximum adjustment, an elevated platform must be provided for the opposite side. When testing on a level surface, both legs of manual levelers shall be fully extended.The test unit shall be
21、 placed at a 75- degree working angle, as shown in Figure 4, with both locks engaged. For combination ladders, a slightly modified angle shall be used so that the tread portion of the steps is horizontal (level). A downward distributed load, in accordance with Table 2, shall be applied for a period
22、of 1 minute to the top fly rung on ladders with extendable section(s) and to the top rung of single ladders or articulating ladders without extendable sections. The load shall be applied equally to both side rails using two 3-1/2 inch straps, each located next to a rail and centrally loaded through
23、an equalizer bar below the climbing side of the ladder. The leveler shall withstand this test without ultimate failure. Permanent deformation in the leveler or in other parts of the ladder structure due to the test is not a test failure. However, the ladder shall still support the test load after th
24、e application of the load, even if the leveler or other parts of the ladder assumed permanent deformation (set).9.3.1.4 Static Leveler Cantilever Bending Test. The leveler shall be attached to the base section of the ladder test unit as specified in 9.3.1. Any swiveling American National Standard A1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIALILADDERA1482013SAFETYREQUIREMENTSFORLADDERACCESSORIESPDF

链接地址:http://www.mydoc123.com/p-1242145.html