IEC 60345-1971 Method of test for electrical resistance and resistivity of insulating materials at elevated temperatures《绝缘材料在高温下电阻和电阻率的试验方法》.pdf
《IEC 60345-1971 Method of test for electrical resistance and resistivity of insulating materials at elevated temperatures《绝缘材料在高温下电阻和电阻率的试验方法》.pdf》由会员分享,可在线阅读,更多相关《IEC 60345-1971 Method of test for electrical resistance and resistivity of insulating materials at elevated temperatures《绝缘材料在高温下电阻和电阻率的试验方法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、IEC 345 71 4 on doit utiliser un systme trois lectrodes dont une lectrode garde. Les diffrences dpaisseur dun bord lautre dune plaque ne doivent pas dpasser 5%. Les lectrodes de lprouvette doivent tre de prfrence circulaires et constitues par un vernis conducteur cuit ou par une couche conductrice p
2、ouvant tre applique par vaporisation ou par pulvrisation. Lor et le platine sont des mtaux appropris; largent ne devrait pas tre employ, tant donn le risque de migration aux tempratures leves. Les couches minces dor peuvent perdre leur conductivit car lor peut sagglomrer temprature leve. I1 est asse
3、z dacile dappliquer des lectrodes par vaporisation ou par pulvrisation sur des matriaux poreux, de sorte que les rsultats obtenus peuvent tre de valeur douteuse. Afn de rduire leffet de surface aux angles de lprouvette (effet qui est parfois d aux manipulations lors de la prparation de lprouvette),
4、la distance minimale entre llectrode et langle de lprouvette devrait tre de 0,5 cm si aucune lectrode garde nest utilise. 3. Appareillage dessai 3.1 Mesure de rsistance (voir Jigure I, page 12) la sensibilit et la prcision requises (voir Publication 93 de la CEI). La rsistance entre les lectrodes do
5、it tre mesure au moyen dun dispositif appropri prsentant 3.2 Enceinte de chauflage Le chauffage des prouvettes se fait dans un four ou dans une tuve lectriques appropris. Le dispositif de chauffage doit permettre de soumettre lprouvette une temprature uniforme dans tout son volume avec fluctuations
6、aussi faibles que possible. Un moufle appropri est prvoir pour protger lprouvette du rayonnement direct des lments de chauffage. Le moufle peut tre en une cramique, telle que loxyde daluminium, ou en tout autre matriau quivalent. En outre, il y a lieu de prvoir lintrieur du four ou de lenceinte un c
7、ran mtallique mis la terre, en argent, en acier inoxydable ou en tout autre mtal quivalent, Cet cran sert mettre labri de linfluence des l- ments de chauffage lprouvette et le disnositif de mesure. Dans le cas dprouvettes rsistance trs leve, il peut tre ncessaire de couper le circuit de chauffage pe
8、ndant la mesure, afin de ne pas fausser les rsultats. . . . -5- METHOD OF TEST FOR ELECTRICAL RESISTANCE AND RESISTIVITY OF INSULATING MATERIALS AT ELEVATED TEMPERATURES 1. Scope This test method covers procedures for the determination of insulation resistance and volume resistivity of insulating ma
9、terials at temperatures up to at least 800 OC. The measurements shall be made in accordance with IEC Publication 93, Recommended Methods of Test for Volume and Surface Resistivities of Electrical Insulating Materials, and with IEC Publi- cation 167, Methods of Test for the Determination of the Insul
10、ation Resistance of Solid Insulating Materials, utilizing the following special procedures. 2. Preparation of specimens and electrodes For insulation resistance measurements, the specimens may be of any suitable size and shape and may have electrodes already attached (see IEC Publication 167). When
11、volume resistivity is measured, the specimens shall preferably be in the form of disks, a three electrode system shall be used, one of which is a guarded electrode. The thickness variation between any two places on the disk shall be no greater than 5% of the mean thickness. The specimen electrodes s
12、hall preferably be circular and consist of red-on conducting paint or a conducting coating evaporated or sprayed onto the specimen faces. Gold or platinum are suitable electrode metals. Silver should not be used since it migrates at elevated temperatures. Thin layers of gold may lose their conductiv
13、ity since the gold may agglomerate at the higher temperatures. It is difficult to apply evaporated or sprayed-on electrodes to porous test specimens and the results obtained with them are of doubtful value. To minimize surface effects at the edges of the specimen (due sometimes to handling in specim
14、en . preparation), it is recommended that if no guarded electrode is used, the minimum distance from the electrodes to the specimen edge shall be 0.5 cm. 3. Test equipment 3.1 Resistance measurement (see Figure 1, page 12) The resistance between electrodes shall be measured with a suitable device ha
15、ving the required sensitivity and accuracy (see IEC Publication 93). 3.2 Heating chamber For heating the specimen, a suitable electric oven or furnace shall be used. The construction shall be such that the specimen is subjected to a uniform temperature throughout its total volume with temperature fl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEC603451971METHODOFTESTFORELECTRICALRESISTANCEANDRESISTIVITYOFINSULATINGMATERIALSATELEVATEDTEMPERATURES

链接地址:http://www.mydoc123.com/p-1234378.html