1、GA-254-07 Copyright Gypsum Association 2007. All rights reserved. Printed in U.S.A. FIRE-RESISTANT GYPSUM SHEATHING (GA-254-07) Gypsum sheathing is manufactured with a water-resistive gypsum core and paper. It is a versatile, economi-cal, water-resistive sheathing. Gypsum sheathing is in-tended for
2、use as a substrate under exterior wall claddings in any climate. Gypsum sheathing is designed to be me-chanically attached to the outside surface of exterior wall framing spaced up to 24 in. (610 mm) o.c. using either nails, screws, or staples. Gypsum sheathing is manufactured in a wide range of len
3、gths to meet the demanding needs of the construction industry. Easily sized, cut, and installed, gypsum sheathing is the sheathing of choice wherever fire resistance ratings or noncombustible materials are required. Low material and labor costs are important economic ad-vantages gained by the use of
4、 this water- resistive sheath-ing. USES Gypsum sheathing can be used with virtually all ext e-rior wall claddings, including wood siding and shingles, panel siding, vinyl or metal siding, masonry or brick ve-neer, portland cement stucco, and Exterior Insulation and Finish Systems (EIFS).1 Mechanical
5、ly attached exterior wall claddings are at-tached through the sheathing and into the wall fra ming. Exterior Insulation and Finish Systems (EIFS) that incorporate gypsum sheathing are used with either me-chanical fasteners or adhesives for the application of the insulation, depending on the EIFS man
6、ufacturers recom-mendations. The performance of EIFS and recommenda-tions for the proper method of attachment are the sole re-sponsibility of the EIFS manufacturer and/or applicator. Fire Protection The natural noncombustible core of gypsum sheathing protects the framing from the hazards of fires oc
7、curring outside the building, even when covered by combustible siding. When exposed to high temperatures, chemically combined water in the gypsum is gradually released, pro-viding protection until all of its combined water is com-pletely driven off. In addition to its fire resistance proper-ties, gy
8、psum sheathing has a low flame spread rating2 of less than 25 as compared to a rating of 100 for red oak. Where fire -rated and/or sound control systems are desired or required, the test report or listing should be reviewed for complete information on systems and component parts used to achieve the
9、necessary fire or sound rating.3 Structural Integrity Racking tests have been conducted for the Gy psum Association by an independent laboratory according to ASTM Method E 72. Refer to Application of Gypsum Sheathing (GA -253) for details. Wall Bracing Building codes permit the use of vertically app
10、lied 4 ft. (1220 mm) wide panels of in. (12.7 mm) gypsum sheathing in place of continuous diagonal wall bracing. Shear Walls In areas where potential wind or seismic forces require shear walls to resist lateral forces, building codes provide allowable shear values for walls having gyp-sum sheathing
11、applied to wood fra ming. Specific values with construction requirements and limitations are con-tained in the building codes. Vapor Permeability Gypsum sheathing typically has an average vapor per-meance of 20 perms (dry cup method). This is well above the accepted minimum of five perms when the “U
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GA2542007FIRERESISTANTGYPSUMSHEATHING 防火 石膏 盖板 铺盖 PDF

链接地址:http://www.mydoc123.com/p-1228983.html