VA FED H-08-1 SEC 15489-2004 ORAL EVACUATION SYSTEM《口腔真空抽吸系统》.pdf
《VA FED H-08-1 SEC 15489-2004 ORAL EVACUATION SYSTEM《口腔真空抽吸系统》.pdf》由会员分享,可在线阅读,更多相关《VA FED H-08-1 SEC 15489-2004 ORAL EVACUATION SYSTEM《口腔真空抽吸系统》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、11-04M 15489-1 SECTION 15489 ORAL EVACUATION SYSTEM SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION This section specifies central piped high volume
2、oral evacuation (HVE) system for dental operatories, valving, vacuum producers, separators, electric motors, starters and controls. 1.2 RELATED WORK A. Sealing around pipe penetrations to maintain the integrity of time rated construction: Section 07270, FIRESTOPPING. B. Sealing around pipe penetrati
3、ons through the floor to prevent moisture migration, Section 07920, SEALANTS AND CAULKING. C. Piping system identification: Section 09900, PAINTING. D. General requirements and items common to more than one section of Division 15: Section 15050, BASIC METHODS AND REQUIREMENTS (MECHANICAL). E. Valves
4、 and strainers (as required for water): Section 15400, PLUMBING SYSTEMS. F. Electric Motors: Section 16150, MOTORS. G. Motor Starters: Section 16155, MOTOR STARTERS. 1.3 QUALITY ASSURANCE A. System: Each vacuum producer shall be sized to produce 27 kPa (8 inches of mercury) at an airflow of 423 L/mi
5、n 15 standard cubic feet per minute (SCFM) per utility junction center (UJC) with 70 percent of the UJCs in operation. System pressure drop shall be a maximum of 3 kPa (1 in-Hg) at the calculated demand flow. 1.4 SUBMITTALS A. Submit in accordance with Section 01340, SAMPLES AND SHOP DRAWINGS. B. Ma
6、nufacturers Literature and Data: Submit the following as one package: 1. Piping 2. Vacuum producer 3. Vacuum cleaning inlet 4. Vacuum gage Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-04M 15489-2 5. Separator 6. Vacuum relief valve 7. Butterfly
7、 valve 8. Directional flow valve 9. Anti-surge valve 10. Exhaust Silencer 11. Separator Drainage Pump/ 12. Control Panel 1.5 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are in the text by the basic designation
8、only. B. American National Standards Institute (ANSI): A13.1-96 Scheme for the Identification of Piping System B16.3-98.Malleable Iron Threaded Fittings B16.22-01.Wrought Copper and Bronze Solder-Joint Pressure Fittings B40.1-98. Pressure Gauges and Gauge Attachments C. American Society for Testing
9、and Materials (ASTM): A47-99 .Ferritic Malleable Iron Castings A53-02 .Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless A536-84(1999) e1Ductile Iron Castings B306-02Copper Drainage Tube (DWV) D1785-03 .Poly (Vinyl Chloride) PVC Plastic Pipe Schedule 40, 80, 120 D2564-96 .Solvent Ce
10、ments for Poly (Vinyl Chloride) (PVC) Plastic pipe and fittings D2466-02 .Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 D3311-94 .Drain, Waste, and Vent (DWV) Plastic Fittings D. National Fire Protection Association NFPA 99c 2002 Edition.Level 3 Vacuum Provided by IHSNot for ResaleN
11、o reproduction or networking permitted without license from IHS-,-,-11-04M 15489-3 PART 2 - PRODUCTS SPEC WRITER NOTE: Update material requirements to agree with applicable requirements (types, grades, classes, and other related items) specified in the reference applicable publications. Where instal
12、lation requires extra strength or higher class pipe, adjust the following. 2.1 PIPING A. Poly (Vinyl Chloride) (PVC): 1. PVC Piping: ASTM D1785, Type 1 (normal impact), Grade 1 (chemical resistance), Schedule / 40 / 80 / pipe. Provide socket ASTM D2566 fittings and ASTM D2564 PVC solvent cement with
13、 PVC primer recommended by manufacturer. Provide DWV (drain-waste-vent). Use long radius fittings for turns and wye fittings for branching, as defined in Section 15400, PLUMBING SYSTEM. B. Galvanized Steel: Use only for discharge from vacuum producer, as per manufacturers instructions. 1. Pipe: ASTM
14、 A53, standard weight. 2. Fittings: a. Flexible groove type, malleable iron, ASTM A47, or Ductile iron, ASTM A536. b. Malleable iron screwed, ANSI B16.3. C. Cleanouts: Same size and material as pipe. Provide accessible and easily removable cleanouts. As defined in Section 15400, Plumbing system D. A
15、pply piping identification ANSI A13.1. /2.2 DENTAL ORAL EVACUATION VACUUM PUMP/ A. Provide a completely packaged, continuous duty dental vacuum duplex system as shown on the drawings and specified. B. Duplex or multiplex systems shall consist of two or more separate high efficiency positive displace
16、ment oil sealed, rotary vane pumps with automatic continuous oil flow to all moving parts. Operation shall be waterfree. C. Duplex or multiplex systems shall be powered by two separate standard NEMA frame motors with V-belt drives enclosed in a UL approved guard. Provided by IHSNot for ResaleNo repr
17、oduction or networking permitted without license from IHS-,-,-11-04M 15489-4 D. Provide two (2) 50-gallon fiberglass wet separator tanks. Tanks shall be pressure tested and certified for 18-inch Hg. Tanks shall be freestanding with legs. Provide tank drain with check valve. E. Provide an electronic
18、moisture alarm system capable of detecting liquid or foam overflows. Moisture sensors shall be located outside the wet tank. F. 3 phase Motor control center shall be completed with motor starters, overload protection and single phasing protection and control transformers. G. Controls shall be digita
19、l with LED status indicators for “power” and “motor on”; and solid state moisture alarm circuitry, moisture detector and wiring harness, manual start-stop switch, and bypass for moisture alarm and remote on-off circuitry, and indicator for required maintenance. H. System shall have a ten-year warran
20、ty against pump wear-out or failure. I. System shall be UL 2601-1 Dental Vacuum System listed and a FDA Registered Medical Device. J. Rated “Acceptable for Federal Service Use by USAF Dental Investigation Service and recommended shipboard use by the US Navy. K. Unit shall be RAMVAC or equal. /2.3 VA
21、CUUM PRODUCER/ A. Duplex or multi-plex self-governing, multi-stage, centrifugal, turbine type of outboard design with bearings on both ends of the exhauster shaft, maximum speed of 3600 rpm, two self-aligning radial bearings sealed with grease fitting or with oil-cup lubrication, connected to its dr
22、iving motor by flexible coupling. Vacuum produced shall be substantially constant throughout the operating range. B. Cylindrical turbine cases, constructed of heavy-gage sheet steel with continuous welds at all seams or sections. Inlet and exhaust connections tangential to the casing and sized to al
23、low air to move freely (within operational range) through the turbine without air restriction of any kind. Turbine shall have not less than 3.2 mm (0.125 inch) internal clearance throughout. C. Motor and Starter: 1. Maximum 40 degree C ambient temperature rise motor, ball or roller bearing for opera
24、ting with current, voltage, phase and cycle as specified in section 16150, Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-04M 15489-5 MOTORS; open dripproof construction, continuous duty rated with service factor of 1.15 or greater; sufficient ca
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VAFEDH081SEC154892004ORALEVACUATIONSYSTEM 口腔 真空 抽吸 系统 PDF

链接地址:http://www.mydoc123.com/p-1075041.html