VA FED H-08-1 SEC 08725-2004 LOW ENERGY POWER ASSIST DOOR OPERATORS《低能动力控制门操作员》.pdf
《VA FED H-08-1 SEC 08725-2004 LOW ENERGY POWER ASSIST DOOR OPERATORS《低能动力控制门操作员》.pdf》由会员分享,可在线阅读,更多相关《VA FED H-08-1 SEC 08725-2004 LOW ENERGY POWER ASSIST DOOR OPERATORS《低能动力控制门操作员》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、03-04M 08725-1 SECTION 08725 LOW ENERGY POWER ASSIST DOOR OPERATORS SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION This section specifies equipment,
2、 controls and accessories required to provide low energy power assisted automatic operation of swing doors. The door operator system shall be complete including operator, controls, door arm and operator enclosure (header and cover). 1.2 RELATED WORK A. Masonry; Section 04200, UNIT MASONRY. B. Sealan
3、ts; Section 07920, SEALANTS AND CAULKING C. Steel doors; Section 08110, STEEL DOORS AND FRAMES. D. Wood doors; Section 08201, WOOD DOORS AND FRAMES. E. Aluminum frames entrance work; Section 08410, ALUMINUM ENTRANCES AND STORE FRONTS. F. Door hardware; Section 08710, BUILDERS HARDWARE. G. Glass and
4、glazing of doors and frames; Section 08810, GLASS AND GLAZING. H. Finish Color, Section 09050, INTERIOR/ EXTERIOR FINISHES, MATERIALS AND FINISH SCHEDULE. I. Smoke detectors for control of fire/smoke doors to be wired per Section 13850, FIRE ALARM SYSTEMS. J. Electric general wiring, connections and
5、 equipment requirements; Division 16, ELECTRICAL. 1.3 MANUFACTURERS QUALIFICATIONS A. Power assisted door operators, controls and other equipment shall be products of a manufacturer regularly engaged in manufacturing such equipment for a minimum of three years. B. One manufacturer of automatic door
6、equipment shall be used throughout the building / project /. 1.4 GUARANTEE Power assisted door operators, controls and other related equipment shall be subject to the terms of the “Guaranty“ Article of Section Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
7、IHS-,-,-03-04M 08725-2 01001, GENERAL CONDITIONS, except that the Guaranty period shall be two years in lieu of one year. 1.5 MAINTENANCE MANUALS In accordance with section 01010, GENERAL REQUIREMENTS Article titled “INSTRUCTIONS,“ furnish / two / three / copies of maintenance manuals and instructio
8、ns on automatic door operators. 1.6 SUBMITTALS A. Submit in accordance with Section 01340, SAMPLES AND SHOP DRAWINGS. B. Manufacturers literature and data describing operators, power units, controls, door hardware and safety devices. C. Shop Drawings: Showing location of controls and safety devices
9、in relationship to each automatically operated door. This includes templates, wiring diagrams, fabrication details, anchorage and other information to providers of related work to coordinate the proper installation of the door operators. 1.7 DESIGN CRITERIA A. Power assisted automatic door equipment
10、 shall accommodate normal traffic as well as the weight of the doors. B. Equipment: UL approved and comply with applicable codes. Motors shall be rated minimum one-quarter horsepower and shall be single phase and 115 volts. C. Electrical Wiring; Provide wiring so that only a single power supply is r
11、equired. Equipment and wiring shall be as specified in Division 16, ELECTRICAL. 1.8 APPLICABLE PUBLICATIONS SPEC WRITER NOTE: Make material and product requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to t
12、he project. A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American National Standards Institute (ANSI): Provided by IHSNot for ResaleNo reproduction or networking permitted wi
13、thout license from IHS-,-,-03-04M 08725-3 A117.1-98.Guideline for Accessible and Usable Buildings and Facilities-Providing Accessibility and Usability for Physically Handicapped People B. Builders Hardware Manufacturers Association, Inc. (BHMA): 156.19-02.Power Assist and Low Energy Power Operated D
14、oors C. National Fire Protection Association (NFPA): 80-99.Fire Doors and Windows 101-03Life Safety Code PART 2 - PRODUCTS SPEC WRITERS NOTE: Low energy automatic door operators are not recommended for high traffic doors. Coordinate door locations and operations with VAMC staff. Doors shall have har
15、dware for manual operation in event of power failure. Door hardware and door operators shall be by manufacturer of existing products where possible. Discuss with the VAMC staff for emergency power requirement. 2.1 OPERATORS A. Automatic door operators shall be for institutional doors and shall be el
16、ectromechanical and surface mounted above the door to the header or transom bar. The opening force shall be generated by a permanent magnet DC motor driving a combination spiral bevel/spur gear reducer and transmitted to the door through an arm linkage. Opening speed shall be adjustable and feature
17、dual backcheck control allowing adjustment of backcheck speed and position. Closing shall be by spring force generated by a metal compression spring. The spring shall reduce manual opening force to not more than 67 N (15 lbf). The minimum diameter of spring wire shall be .007mm (172 in.). Under the
18、specified design load of the door, the spring shall be capable of performing 2,000,000 cycles before fracture. Adjustable closing speed and fixed latch speed shall control the door in the closing cycle. The doors shall be operated manually at any time without damage to the operator or components. B.
19、 All operators shall have checking mechanism providing cushioning action at last part of door travel, in both opening and closing cycle. Operators shall recycle doors instantaneously to full open position from any point in closing cycle when control switch is reactivated. Provided by IHSNot for Resa
20、leNo reproduction or networking permitted without license from IHS-,-,-03-04M 08725-4 C. Operator shall be swinging type enclosed in housing. Operator shall open door by energizing motor and shall stop by electrically reducing voltage and stalling motor against mechanical stop. Door shall close by m
21、eans of spring energy, and close force shall be controlled by gear system and motor being used as dynamic break without power. System shall operate as manual door control in event of power failure. Opening and closing speeds shall be adjustable. 1. Swing Operator Housing: Housing shall be 140 mm (5-
22、1/2 inches) wide by 150 mm (6 inches) high aluminum extrusions with enclosed end caps for application to 100 mm (4 inch) and larger frame systems. All structural sections shall have a minimum thickness of 3.7 mm (0.146 inch) and be fabricated of 6063-T5 aluminum alloy. 2. Swing Power Operator: Compl
23、etely assembled and sealed unit which shall include helical gear drive transmission, mechanical spring and bearings, all located in cast aluminum case and filled with special lubricant for extreme temperature conditions. A “DC“ shunt-wound permanent magnet motor with sealed ball bearings shall be at
24、tached to transmission system. Complete unit shall be rubber mounted with provisions for easy maintenance and replacement, without removing door from pivots or frame. 3. Connecting hardware for swing overhead concealed type power operator shall have drive arm attached to door with a pin linkage rota
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VAFEDH081SEC087252004LOWENERGYPOWERASSISTDOOROPERATORS 低能 动力 控制 操作员 PDF

链接地址:http://www.mydoc123.com/p-1075037.html