1、11-11 10 14 00 - 1 SECTION 10 14 00 SIGNAGE SPEC WRITER NOTE: 1. Delete /-/if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Coordinate with Medical Center for types of signs, colors or to match existing signs. 3. Coor
2、dinate interior sign type designations with VA Signage Design Guide. 4. Coordinate with drawing terminology for correct and uniform nomenclature. 5. Coordinate with electrical for location of junction boxes and service required for lighted signs. PART 1 - GENERAL 1.1 DESCRIPTION A. This section spec
3、ifies interior signage for room numbers, directional signs, code required signs, telephone identification signs and temporary interior signs. B. This section also specifies exterior medical center identification signs, building identification signs, parking and traffic signs. C. Installation of Gove
4、rnment furnished dedication plaque and VA seal. 1.2 RELATED WORK A. Electrical: Related Electrical Specification Sections. B. Lighted EXIT signs for egress purposes are specified under Division 26, ELECTRICAL. C. Section 10 13 00, DIRECTORIES and Section 10 14 00, SIGNAGE. D. Color Finish: Section 0
5、9 06 00, SCHEDULE FOR FINISHES. 1.3 MANUFACTURERS QUALIFICATIONS Sign manufacturer shall provide evidence that they regularly and presently manufactures signs similar to those specified in this section as one of their principal products. 1.4 SUBMITTALS A. Submit in accordance with Section 01 33 00,
6、SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. B. Samples: Sign panels and frames, with letters and symbols, each type. Submit 2 sets. One set of samples will be retained by Resident Engineer, other returned to Contractor. 1. Sign Panel, 200 mm x 250 mm (8 inches x 10 inches), with letters. Provided by IH
7、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 10 14 00 - 2 2. Color samples of each color, 150 mm x 150 mm (6 inches x 6 inches. Show anticipated range of color and texture. 3. Sample of typeface, arrow and symbols in a typical full size layout. C. Manufac
8、turers Literature: 1. Showing the methods and procedures proposed for the concealed anchorage of the signage system to each surface type. 2. Manufacturers printed specifications, anchorage details, installation and maintenance instructions. D. Samples: Sign location plan, showing location, type and
9、total number of signs required. E. Shop Drawings: Scaled for manufacture and fabrication of sign types. Identify materials, show joints, welds, anchorage, accessory items, mounting and finishes. F. Full size layout patterns for dimensional letters. 1.5 DELIVERY AND STORAGE A. Deliver materials to jo
10、b in manufacturers original sealed containers with brand name marked thereon. Protect materials from damage. B. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary. C. Deli
11、ver signs only when the site and mounting services are ready for installation work to proceed. D. Store products in dry condition inside enclosed facilities. 1.6 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are
12、referenced in the text by the basic designation only. B. American Society for Testing and Materials (ASTM): B209-07 Aluminum and Aluminum-Alloy Sheet and Plate B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and tubes. C. Federal Specifications (Fed Spec): MIL-PRF-8184F Plasti
13、c Sheet, Acrylic, Modified. MIL-P-46144C . Plastic Sheet, Polycarbonate 1.7 MINIMUM SIGN REQUIREMENTS A. Permanent Rooms and Spaces: 1. Tactile and Braille Characters, raised minimum 0.793 mm (1/32 in). Characters shall be accompanied by Grade 2 Braille. 2. Type Styles: Characters shall be uppercase
14、, Helvetica Medium, Helvetica Medium Condensed and Helvetica Regular. 3. Character Height: Minimum 16 mm (5/8 in) high, Maximum 50 mm (2 in). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 10 14 00 - 3 4. Symbols (Pictograms): Equivalent writt
15、en description shall be placed directly below symbol, outside of symbols background field. Border dimensions of symbol background shall be minimum 150 mm (6 in) high. 5. Finish and Contrast: Characters and background shall be eggshell, matte or other non-glare finish with adequate contrast with back
16、ground. 6. Mounting Location and Height: As shown. Mounted on wall adjacent to the latch side of the door and to avoid door swing and protruding objects. B. Overhead Signs: 1. Type Styles: As shown. Characters shall have a width-to-height ratio between 3:5 and 1:1. Characters shall have a stroke wid
17、th-to-height ratio of between 1:5 and 1:10. 2. Character Height: minimum 75 mm (3 in) high for overhead signs. As shown, for directional signs. 3. Finish and Contrast: Same as for signs of permanent rooms and spaces. 4. Mounting Location and Height: As shown. 1.8 COLORS AND FINISHES: Section 09 06 0
18、0, SCHEDULE FOR FINSIHES. PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 2.1 GENERAL A. Signs of type, size and design shown on the drawi
19、ngs and as specified. B. Signs complete with lettering, framing and related components for a complete installation. C. Provide graphics items as completed units produced by a single manufacturer, including necessary mounting accessories, fittings and fastenings. D. Do not scale drawings for dimensio
20、ns. Contractor to verify and be responsible for all dimensions and conditions shown by these drawings. Resident Engineer to be notified of any discrepancy in drawing, in field directions or conditions, and/or of any changes required for all such construction details. E. The Sign Contractor, by comme
21、ncing work of this section, assumes overall responsibility, as part of his warranty of work, to assure that assemblies, components and parts shown or required within the work of the section, comply with the Contract Documents. The Contractor shall Provided by IHSNot for ResaleNo reproduction or netw
22、orking permitted without license from IHS-,-,-11-11 10 14 00 - 4 further warrant: That all components, specified or required to satisfactorily complete the installation are compatible with each other and with conditions of installations. 2.2 PRODUCTS A. Aluminum: 1. Sheet and Plate: ASTM B209. 2. Ex
23、trusions and Tubing: ASTM B221. B. Cast Acrylic Sheet: MIL-PRF-8184F; Type II, class 1, Water white non-glare optically clear. Matt finish water white clear acrylic shall not be acceptable. C. Polycarbonate: MIL-P-46144C; Type I, class 1. D. Vinyl: 0.1 mm thick machine cut, having a pressure sensiti
24、ve adhesive and integral colors. E. Electrical Signs: 1. General: Furnish and install all lighting, electrical components, fixtures and lamps ready for use in accordance with the sign type drawings, details and specifications. 2. Refer to Electrical Specifications Section, Division 26, ELECTRICAL, t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1014002011SIGNAGEPDF