1、11-11 10 13 00- 1 SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTE: 1. Delete /-/if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Coordinate with Medical Center for types of signs, colors or to match existing signs. 3. C
2、oordinate interior sign type designations with VA Signage Design Guide. 4. Coordinate with drawing terminology for correct and uniform nomenclature. 5. Coordinate with electrical for location of junction boxes and service required for lighted directories. PART 1 - GENERAL 1.1 DESCRIPTION A. This sec
3、tion specifies interior directories. B. This section also specifies exterior medical center directional signs, directories and information. 1.2 RELATED WORK A. Electrical: Related Electrical Specification Sections. B. Section 10 14 00, SIGNAGE/ Section 10 13 00, DIRECTORIES. C. Finishes, Division 09
4、, FINISHES. 1.3 MANUFACTURERS QUALIFICATIONS Sign manufacturer shall provide evidence that they regularly and presently manufactures signs similar to those specified in this section as one of their principal products. 1.4 SUBMITTALS A. Submit in accordance with Section 01 33 00, SHOP DRAWINGS, PRODU
5、CT DATA AND SAMPLES. B. Samples: Directory panels and frames, with letters and symbols, each type. Submit 2 sets. One set of samples will be retained by Resident Engineer, other returned to Contractor. 1. Color samples of each color, 150 mm x 150 mm (6 inches x 6 inches. Show anticipated range of co
6、lor and texture. 2. Sample of typeface, arrow and symbols in a typical full size layout. C. Manufacturers Literature: 1. Showing the methods and procedures proposed for the concealed anchorage of the directory system to each surface type. Provided by IHSNot for ResaleNo reproduction or networking pe
7、rmitted without license from IHS-,-,-11-11 10 13 00- 2 2. Manufacturers printed specifications, anchorage details, installation and maintenance instructions. D. Samples: Directory location plan, showing location, type and total number of signs required. E. Shop Drawings: Scaled for manufacture and f
8、abrication of sign types. Identify materials, show joints, welds, anchorage, accessory items, mounting and finishes. F. Full size layout patterns for dimensional letters. 1.5 DELIVERY AND STORAGE A. Deliver materials to job in manufacturers original sealed containers with brand name marked thereon.
9、Protect materials from damage. B. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary. C. Deliver directories only when the site and mounting services are ready for install
10、ation work to proceed. D. Store products in dry condition inside enclosed facilities. 1.6 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American Societ
11、y for Testing and Materials (ASTM): B209-07 Aluminum and Aluminum-Alloy Sheet and Plate B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and tubes. C. Federal Specifications (Fed Spec): MIL-PRF-8184F Plastic Sheet, Acrylic, Modified. MIL-P-46144C . Plastic Sheet, Polycarbonate
12、1.7 MINIMUM SIGN REQUIREMENTS A. Directional/Informational Signs: 1. Type Styles: As shown. Characters shall have a width-to-height ratio between 3:5 and 1:1. Characters shall have a stroke width-to-height ratio of between 1:5 and 1:10. 2. Character Height: minimum 75 mm (3 in) high for overhead sig
13、ns. As shown, for directional signs. 4. Mounting Location and Height: As shown. 1.8 COLORS AND FINISHES: Section 09 06 00, SCHEDULE FOR FINSIHES. PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable Provided by IHSNot for ResaleNo reproduction or networking permitted
14、without license from IHS-,-,-11-11 10 13 00- 3 requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 2.1 GENERAL A. Signs of type, size and design shown on the drawings and as specified. B. Signs complete with lettering, framing
15、and related components for a complete installation. C. Provide graphics items as completed units produced by a single manufacturer, including necessary mounting accessories, fittings and fastenings. D. Do not scale drawings for dimensions. Contractor to verify and be responsible for all dimensions a
16、nd conditions shown by these drawings. Resident Engineer to be notified of any discrepancy in drawing, in field directions or conditions, and/or of any changes required for all such construction details. E. The Sign Contractor, by commencing work of this section, assumes overall responsibility, as p
17、art of his warranty of work, to assure that assemblies, components and parts shown or required within the work of the section, comply with the Contract Documents. The Contractor shall further warrant: That all components, specified or required to satisfactorily complete the installation are compatib
18、le with each other and with conditions of installations. 2.2 PRODUCTS A. Aluminum: 1. Sheet and Plate: ASTM B209. 2. Extrusions and Tubing: ASTM B221. B. Cast Acrylic Sheet: MIL-PRF-8184F; Type II, class 1, Water white non-glare optically clear. Matt finish water white clear acrylic shall not be acc
19、eptable. C. Polycarbonate: MIL-P-46144C; Type I, class 1. D. Vinyl: 0.1 mm thick machine cut, having a pressure sensitive adhesive and integral colors. E. Electrical Directories: 1. General: Furnish and install all lighting, electrical components, fixtures and lamps ready for use in accordance with
20、the sign type drawings, details and specifications. 2. Refer to Electrical Specifications Section, Division 26, ELECTRICAL, to verify line voltages for sign locations that require electrical signs. 3. Quality Control: Installed electrical components and sign installations are to bear the label and c
21、ertification of Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 10 13 00- 4 Underwriters Laboratories, Inc., and are to comply with National Electrical Code as well as applicable federal, state and local codes for installation techniques, fabri
22、cation methods and general product safety. 4. Ballast and Lighting Fixtures: See Electrical Specifications. F. Concrete Post Footings: See Section 03 30 53, MISCELLANEOUS CAST-IN-PLACE CONCRETE, Cast-in-place Concrete. G. Steel: See Section 05 12 00, STRUCTURAL STEEL FRAMING. 2.3 SIGN STANDARDS A. T
23、opography: 1. Type Style: Helvetica Medium and Helvetica Medium Condensed. Initial caps or all caps as indicated in Sign Message Schedule. 2. Arrow: See graphic standards in drawings. 3. Letter spacing: See graphic standards on drawings. 4. Letter spacing: See graphic standards on drawings. 5. All t
24、ext, arrows, and symbols to be provided in size, colors, typefaces and letter spacing shown. Text shall be a true, clean, accurate reproduction of typeface(s) shown. Text shown in drawings are for layout purposes only; final text for signs is listed in Sign Message Schedule. B. Project Colors and Fi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA1013002011DIRECTORIESPDF