VA 08 51 23-2011 STEEL WINDOWS.pdf
《VA 08 51 23-2011 STEEL WINDOWS.pdf》由会员分享,可在线阅读,更多相关《VA 08 51 23-2011 STEEL WINDOWS.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、10-11 08 51 23 - 1 SECTION 08 51 23 STEEL WINDOWS SPEC WRITER NOTE: 1. Delete between /-/if not applicable to project. Also delete any other item or paragraph not applicable in section and renumber paragraphs. 2. Single hung or double hung window type described herein may only be used in general mai
2、ntenance or utility type buildings. PART 1 - GENERAL 1.1 DESCRIPTION: A. Section Includes: 1. Steel / single hung / / double hung / windows, type and sizes as shown. 2. Hardware. 3. Accessories including, but not limited to, following: a. Mullions, closures, trim, weather-stripping, covers, insect s
3、creens, anchors, clips, fasteners, and other components necessary for fabrication and installation complete of windows as specified. /b. Provide manufacturers standard extension pole with hook for opening windows at high window locations. Provide hook receptacle factory attached to ventilators for u
4、se with extension poles. / 1.2 RELATED WORK: A. Sealing Joints: Section 07 92 00, JOINT SEALANTS. B. Glazing: Section 08 80 00, GLAZING. C. Finish Color: Section 09 06 00, SCHEDULE FOR FINISHES. 1.3 QUALITY CONTROL A. QUALIFICATIONS: 1. Approval is required of products or service of proposed manufac
5、turer, suppliers and installers, and will be based upon submission by Contractor of certification that: a. Manufacturer who regularly and presently, manufactures and installs steel window units and related accessories as one of its principal products. b. Accessories required for windows shall be man
6、ufacturers standard or those of other manufacturers regularly engaged in making window accessories and acceptable to window manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 51 23 - 2 1) Items shall be of materials which shall be
7、 compatible with balance of window unit material, and construction shall be that which shall give desired functional service. 2. Installer: Approved in writing by manufacturer. 1.4 PERFORMANCE REQUIREMENTS: A. Air Infiltration Test at Weather-stripped Ventilators: 1. Operable windows: Provided with
8、weather-stripping, such that when tested in closed and locked position in accordance with ASTM E283 before leaving factory, air infiltration shall not exceed 2.06 cubic meter per hour per meter (0.37 cubic foot per minute per foot) of crack length when subjected to a pressure differential across the
9、 window of 300 Pa (6.24 psf) equivalent to a wind velocity of 50 miles per hour. Fixed window areas: Maximum air infiltration shall not exceed 0.34 cubic meter per hour per meter (0.06 cubic foot per minute per square foot) of fixed window area. B. Water Penetration Test at Weather-stripped Ventilat
10、ors: 1. Operable windows: Provided with weather-stripping, such that when tested in closed and locked position in accordance with ASTM E331 no water penetrates for 15 minutes when a window is subjected to a rate of flow of 5 gal./hr./sq. ft. with a pressure differential across the window at 160 Pa (
11、2.86 psf). 1.5 SUBMITTALS: A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES, furnish following: B. Product Data: Furnish for each type of window required, including: 1. Construction details and fabrication methods. 2. Profiles and dimensions of individual components.
12、3. Data on hardware, including sweep lock, keeper, lift handles, accessories, and finishes. 4. Recommendations for maintenance and cleaning of window surfaces. C. Shop Drawings: Furnish for each type window included in project. 1. Layout and installation details, including anchors, support framing a
13、nd sheet metal trim members. 2. Elevations of continuous work at 1:50 (1/4 inch) scale and typical window unit elevations at 1:20 (3/4 inch) scale. 3. Full-size section details of typical composite members, including reinforcement. 4. Hardware. Provided by IHSNot for ResaleNo reproduction or network
14、ing permitted without license from IHS-,-,-10-11 08 51 23 - 3 5. Accessories. 6. Glazing details. 7. Color charts for standard finishes and sealants. SPEC WRITER NOTE: Samples required only if project has more than 20 windows. D. Samples: 1. Typical sash corner. 2. Typical muntin section. 3. For Ini
15、tial Color Selection: Submit samples of each specified finish on 300 mm (12 inch) long sections of window members. 4. Hardware. E. Quality Control Submittals: 1. Test Reports: Window manufacturer provide certified test report from a qualified independent testing laboratory engaged in testing windows
16、 to verify that his steel window assembly has been tested in accordance with specified test procedures and products comply with these minimum test performance characteristics indicated. Test reports shall have been made within current year. 2. Manufacturers Certificates: a. Stating steel members hav
17、e been given specified thickness of prime coat and/or organic coating finish. b. Indicating manufacturers and installers meet qualifications as specified. 1.6 DELIVERY, STORAGE AND HANDLING: A. Comply with applicable recommendations of Steel Window Institute. B. Deliver steel window units and relate
18、d components in manufacturers original, unopened protective packaging labeled for identification with manufacturers name and brand and contents. Use padded blankets or other approved protective wrapping for glass, decorative metal work, and other exposed elements. 1. Do not deliver steel window unit
19、s until work is ready for their installation. 2. Inspect components for damage upon delivery. Do not install steel window units with dimples or dents. Remove and replace damaged components at no additional cost. C. Storage: Store steel window units and related components, in positions necessary to p
20、revent twisting, in weathertight and dry storage facility in their original shipping containers with protective wrapping or Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 51 23 - 4 packaging securely in place, in accordance with manufacture
21、rs written instructions. D. Protect finish from damage from handling, weather and construction operations before, during and after installation. 1.7 APPLICABLE PUBLICATIONS: A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by ba
22、sic designation only. B. American National Standards Institute (ANSI): Z97.1-09 . Glazing Materials Used in Buildings, Safety Performance Specifications and Methods of Test. C. American Society for Testing and Materials (ASTM): A123-09 Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. B
23、633-07 Electrodeposited Coatings of Zinc on Iron and Steel C509-06 Elastomeric Cellular Preformed Gasket and Sealing Material. D2287-96(2010) . Non-rigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds E283-04 Test Method for Determining Rate of Air Leakage Through Exterior Wind
24、ows, Curtain Walls and Doors Under Specified Pressure Differences Across Specimen. E331-00(R2009) . Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. D. National Fire Protection Association: NFPA 80-10. Standard for Fire Doors
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0851232011STEELWINDOWSPDF