VA 08 44 13-2011 GLAZED ALUMINUM CURTAIN WALLS.pdf
《VA 08 44 13-2011 GLAZED ALUMINUM CURTAIN WALLS.pdf》由会员分享,可在线阅读,更多相关《VA 08 44 13-2011 GLAZED ALUMINUM CURTAIN WALLS.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、10-11 08 44 13 - 1 SECTION 08 44 13 GLAZED ALUMINUM CURTAIN WALLS SPEC WRITER NOTE: Delete between / - / if not applicable to project. Delete any other item or article not applicable in Section and renumber paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION A. Section specifies glazed aluminum curtain wal
2、l system. 1. Thermally isolated, pressure equalized on interior. 2. Type: / Stick / Unit / Unit and Mullion / system to include following: a. / Glass / Insulated Metal Panels / Uninsulated Metal Panels / Glass Spandrel Panels / . b. Integral reinforcing. c. Closures, trim, subsills and flashings. d.
3、 Column covers. e. Fasteners, anchors, and related reinforcement. 1.2 RELATED WORK A. Structural steel: Section 05 12 00, STRUCTURAL STEEL FRAMING. B. Miscellaneous metal members: Section 05 50 00, METAL FABRICATIONS. C. Firestopping between curtain wall and structure: Section 07 84 00, FIRESTOPPING
4、. D. Sheet metal flashing and trim: Section 07 60 00, FLASHING AND SHEET METAL. a. Joint sealants: Section 07 92 00, JOINT SEALANTS. /E. Aluminum and glass hinged entry doors and storefront construction: Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS. / /F. Revolving entrance doors: Sec
5、tion 08 42 33, REVOLVING DOOR ENTRANCES. / /G. Aluminum windows: Section 08 51 13, ALUMINUM WINDOWS. / /H. Aluminum windows: Section 08 51 13.11, SIDE-HINGED ALUMINUM WINDOWS. / /I. Metal framed skylights: Section 08 63 00, METAL-FRAMED SKYLIGHTS. / 1. Glazing: Section 08 80 00, GLAZING. 2. Finish C
6、olor: Section 09 06 00, SCHEDULE FOR FINISHES. 3. Louvers and wall vents: Section 08 90 00, LOUVERS AND VENTS. 1.3 QUALITY ASSURANCE A. Qualifications: 1. Approval is required of products or service of proposed manufacturer, suppliers and installers, and will be based upon submission by Contractor o
7、f certification that: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 44 13 - 2 a. Manufacturers Qualifications: Manufacturer with five (5) years continuous documented experience in / design, / fabrication, / and / installation / of glazed a
8、luminum curtain wall systems of type and size required for that project. b. Installer: Manufacturer approved in writing. Continuously installed glazed aluminum curtain walls systems for previous five (5) years. c. Manufacturer shall provide technical field representation at project site, as a minimu
9、m, at start of project, during middle, towards end of project, and during field testing of field mockup panel. d. Testing Laboratory: Contractor retained. Engage an AAMA accredited commercial testing laboratory to perform tests specified. Submit information regarding testing laboratorys facilities a
10、nd qualifications of technical personnel to perform testing specified in this section. e. Product Options: Information on Drawings and in Specifications establishes requirements for aesthetic effects and performance characteristics of glazed aluminum curtain wall system. Aesthetic effects are indica
11、ted by dimensions, arrangements, alignment, and profiles of components and assemblies as they relate to sightlines, one another, and adjoining construction. Performance characteristics are indicated by criteria subject to verification by one or more methods including preconstruction testing, field t
12、esting, or in-service performance. 1) Do not modify intended aesthetic effects. If modifications are proposed, submit comprehensive explanatory data for review. f. Qualification of Welders: 1) Welding shall be performed by certified welders qualified in accordance with AWS D1.2, using procedures, ma
13、terials, and equipment of the type required for this work. SPEC WRITER NOTES: 1. Delete requirements for mockup if not warranted by project size or portions of Article not deemed necessary. 2. Indicate location size and configuration of mockup panel on architectural contract drawings. /B. Mockup / /
14、1. Construct, at job site, full size typical wall unit which incorporates horizontal and vertical joints, framing, window units, panels, glazing, sealants, and other accessories as detailed and Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08
15、 44 13 - 3 specified. Mock-up wall unit location, size and design shall be as indicated. Orient mockup to be facing full sun when constructed. / /2. Performance Test / /a. Conduct performance test after approval of visual aspects has been obtained. Finished work shall match approved mock-up. / /b. R
16、efer to Performance Requirements and Field Quality Control Articles, included hereinafter, for testing requirements. / /3. Approved Mock-up / /a. After completion and approval of test results of job site mockup, as directed, approved mock-up panel shall be used as minimum standard of comparison for
17、entire curtain wall system. / SPEC WRITER NOTE: Delete this Article if project size does not warrant a pre-installation conference. /C. Pre-Installation Conference / /1. Prior to starting installation of glazed curtain wall system schedule conference with Contracting Officer to ensure following: a.
18、Clear understanding of drawings and specifications. b. Onsite inspection and acceptance of structural and pertinent structural details relating to curtain wall system. c. Coordination of work of various trades involved in providing system. Conference shall be attended by Contractor; personnel direct
19、ly responsible for installation of curtain wall system, flashing and sheet metal work, firestopping system and curtain wall manufacturer and their Technical Field Representatives. Conflicts shall be resolved and confirmed in writing. / 1.4 SUBMITTALS SPEC WRITER NOTES: 1. List below items intended f
20、or use in project, necessary for review prior to manufacture. Refer to Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES for submittal requirements. Include additional submittal requirements for items specified. 2. Samples not required for clear anodized finish. A. In accordance with Sectio
21、n 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Manufacturers Literature and Product Data: 1. Manufacturers standard details and fabrication methods. 2. Data on finishing, components, and accessories. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
22、IHS-,-,-10-11 08 44 13 - 4 3. Instructions: Submit descriptive literature, detail specifications, available performance test data and instructions for installation, and adjustments. 4. Recommendations for maintenance and cleaning of exterior surfaces. C. Shop Drawings: 1. Show elevations of glazed c
23、urtain wall system at 1:50 (1/4 inch) scale, metal gages, details of construction, methods of anchorage, glazing details, and details of installation. 2. Submit for curtain wall system, accessories / , and mock-up / . Tentative approval of drawings shall be received before fabrication of mock-up. Fi
24、nal approval of drawings shall be deferred pending approval of mock-up and accessories. Drawings shall indicate in detail all system parts including elevations, full size sections, framing, jointing, panels, types and thickness of metal anchorage details, flashing and coping details, field connectio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0844132011GLAZEDALUMINUMCURTAINWALLSPDF