VA 08 36 13-2011 SECTIONAL DOORS.pdf
《VA 08 36 13-2011 SECTIONAL DOORS.pdf》由会员分享,可在线阅读,更多相关《VA 08 36 13-2011 SECTIONAL DOORS.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、10-11 08 36 13 - 1 SECTION 08 36 13 SECTIONAL DOORS Spec WRITER NOTE: Delete between /_/, if not applicable to project. Also delete all other items or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: This section specifies electrically operated t
2、hermal insulated sectional overhead steel doors. 1.2 RELATED WORK: A. Overhead roll-up doors: Section 08 33 00, COILING DOORS AND GRILLES. B. Lock cylinders for cylindrical locks: Section 08 71 00, DOOR HARDWARE. C. Field painting: Section 09 91 00, PAINTING. D. Electrical Installation: Section 26 0
3、5 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS/ Section 27 05 11, REQUIREMENTS FOR COMMUNICATIONS INSTALLATIONS/ Section 28 05 11, REQUIREMENTS FOR ELECTRONIC SAFETY AND SECURITY INSTALLATIONS. 1.3 MANUFACTURERS AND INSTALLERS QUALIFICATIONS: A. Manufacturers regularly engaged in manufacturing item
4、s of type specified. B. Installers under direct supervision of manufacturers representative or trained personnel. 1.4 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Details of construction, accessories and hardware, electrica
5、l and mechanical items, supporting brackets for motors, location, and ratings of motors, and safety devices. 2. Wiring diagrams for motors and controls, including wiring diagram for door, showing electrical interlock for motor with manually operated dead lock. C. Manufacturers Literature and Data: 1
6、. Brochures or catalog cuts. 2. Manufacturers installation procedures and instructions. 3. Maintenance instructions, parts list. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 36 13 - 2 D. Certificates: 1. Attesting door, anchors and hardwa
7、re will withstand the horizontal loads specified. 2. Attesting door complies with thermal performance, air infiltration, and water infiltration requirements. 1.5 APPLICABLE PUBLICATIONS: A. Publications listed below form a part of this specification to the extent referenced. Publications are referen
8、ced in the text by the basic designation only. B. American Society for Testing and Materials (ASTM): A36/A36M-08 Structural Steel A227/A227M-06 Steel Wire, Cold-Drawn for Mechanical Springs A229/229M-99(R2005) Steel Wire, Oil-Tempered for Mechanical Springs A653-10 Steel Sheet, Zinc-Coated (Galvaniz
9、ed) or Zinc Iron Alloy Coated (Galvanized) by the Hot Dip Process C1036-06 . Flat Glass E84-10 . Surface Burning Characteristics of Building Materials E283-04 Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Difference Across the Specime
10、n E330-02(R2010) . Structural Performance of Exterior Windows, Curtain Walls, and Doors by the Uniform Static Air Pressure Difference. E331-00(R2009) . Water Penetration of Exterior Windows, Curtain Walls, and Doors by the Uniform Static Air Pressure Difference. C. American National Standards Instit
11、ute and Door and Access Systems Manufacturers Association (ANSI/DASMA): 102-04 . Sectional Overhead Type Doors. D. National Electrical Manufacturers Association (NEMA): ICS 2-00 (R2005) . Industrial Control and Systems: Controllers, Contactors, and Overload Relays MG 1-10 Motors and Generators E. Na
12、tional Fire Protection Association (NFPA): 70-11 National Electrical Code Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 36 13 - 3 F. National Association of Architectural Metal Manufacturers (NAAMM): AMP 500-06 . Metal Finishes Manual PART
13、 2 - PRODUCTS 2.1 MATERIALS: A. Steel: ASTM A653 for forming operations. ASTM A36 for structural sections. B. Hard Drawn Spring wire: ASTM A227. C. Oil Tempered Spring wire: ASTM A229. D. Glass: ASTM C1036 1. Clear Glass: Type 1, Class 1, Quality q5, 6 mm (1/4 inch) thick. 2. Fabricated into sealed
14、insulating glass 25 mm (one inch) thick. E. Weather-strips, Gaskets, and Thermal Breaks: 1. Neoprene, EPDM, PVC, silicone rubber, or other low conductance material. 2. Standard with door manufacturer. 2.2 DESIGN REQUIREMENTS: SPEC WRITER NOTE: Use not less than 960 Pa (20 pounds per square foot) for
15、 wind load. Insert higher loads for locations when required by code. A. Wind Load: Design to withstand a horizontal or wind pressure of 960 Pa (20 pounds per square foot) of door area without damage when tested in accordance with ASTM E330. B. Thermal Performance: Maximum U value of 0.14 for door wh
16、en tested in accordance with ASTM C236. C. Air Infiltration: Maximum of 0.10 cfm at 24 Km (15 miles per hour) wind speed per foot of crack between door sections and door perimeter opening when tested in accordance with ASTM E283. D. Water Infiltration: No infiltration when tested in accordance with
17、ASTM E331. E. Comply with ANSI/NAGDM 102, for an Industrial door and specified design criteria, inside face mounted with tracks at jambs set back a sufficient distance to provide a clear opening when door is in open position. F. Operation-Cycle Requirements: Door components and operators to operate
18、for not less than 10,000 cycles. 2.3 FABRICATION: A. Steel Door Sections: 1. Formed of hot-dipped galvanized steel. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 36 13 - 4 2. Meeting rails: interlocking joints with thermal breaks separatin
19、g face sheets formed to provide weathertight closure and alignment for full width of door. 3. Height of sections: Not to exceed 600 mm (24 inches) may be varied to suit door height. 4. Install glazing panels where indicated using rubber thermal break gaskets standard with door manufacturer. 5. Insul
20、ation shall have a flame spread rating of not more than 25 and a smoke development factor of not more than 50 when tested in accordance with ASTM E 84. 6. Reinforced for hardware anchorage with not less than 10 gage galvanized steel. B. Tracks: 1. Manufacturers standard formed of galvanized steel. 2
21、. Minimum of 14 gage for 50 mm (2 inch) tracks and 12 gage for 75 mm (3 inch) tracks. 3. Vertical tracks fabricated with adjustable brackets for mounting at incline to continuous steel angle wall bracket. 4. Horizontal track: Reinforce with continuous steel angle anchored to vertical steel angle wal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0836132011SECTIONALDOORSPDF