1、05-10 06 20 00 - 1 SECTION 06 20 00 FINISH CARPENTRY SPEC WRITER NOTES: 1. Delete between /_/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Use terminology as listed and coordinate drawings to use the same term. 3.
2、 This section includes custom fabricated architectural woodwork or millwork. 4. List additional items required by the project. 5. See VA standard details, identified in list in parenthesis following item; delete detail reference from project specification. PART 1 - GENERAL 1.1 DESCRIPTION A. This se
3、ction specifies exterior and interior millwork. B. Items specified. - Seats and benches - Communication Center Counter - Folding Shelf: Dressing (Make-Up) - Counter Shelf - Interview Booth - Counter or Work Tops - Wall Paneling - Pegboard (Perforated Hardboard) - Mounting Strips, Shelves, and Rods S
4、PEC WRITER NOTE: The following items do not occur frequently and require specification paragraphs developed for project conditions. - Chair Rail - Moldings and Staff Beads - Base - Wood Bumpers 1.2 RELATED WORK A. Fabricated Metal brackets, bench supports and countertop legs: Section 05 50 00, METAL
5、 FABRICATIONS. B. Framing, furring and blocking: Section 06 10 00, ROUGH CARPENTRY. C. Wood doors: Section 08 14 00, WOOD DOORS. D. Color and texture of finish: Section 09 06 00, SCHEDULE FOR FINISHES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
6、05-10 06 20 00 - 2 E. Stock Casework: Section 12 32 00, MANUFACTURED WOOD CASEWORK. F. Other Countertops: Division 11, EQUIPMENT and Division 12, FURNISHINGS. G. Electrical light fixtures and duplex outlets: Division 26, ELECTRICAL. 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP
7、DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Millwork items Half full size scale for sections and details 1:50 (1/4-inch) for elevations and plans. 2. Show construction and installation. C. Samples: Plastic laminate finished plywood or particleboard, 150 mm by 300 mm (six by twelve inch
8、es). D. Certificates: 1. Indicating / preservative treatment / fire retardant treatment / of materials meet the requirements specified. 2. Indicating moisture content of materials meet the requirements specified. E. List of acceptable sealers for fire retardant and preservative treated materials. F.
9、 Manufacturers literature and data: 1. Finish hardware 2. Sinks with fittings 3. Electrical components 1.4 DELIVERY, STORAGE AND HANDLING A. Protect lumber and millwork from dampness, maintaining moisture content specified both during and after delivery at site. B. Store finishing lumber and millwor
10、k in weathertight well ventilated structures or in space in existing buildings designated by Resident Engineer. Store at a minimum temperature of 210C (700F) for not less than 10 days before installation. C. Pile lumber in stacks in such manner as to provide air circulation around surfaces of each p
11、iece. 1.5 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American Society of Testing and Materials (ASTM): A36/A36M-08 Structural Steel A53-07 . Pipe, S
12、teel, Black and Hot-Dipped Zinc Coated, Welded and Seamless Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 3 A167-99 (R2009) Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip B26/B26M-09 Aluminum-Alloy Sand
13、Castings B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes E84-09 . Surface Burning Characteristics of Building Materials C. American Hardboard Association (AHA): A135.4-04 Basic Hardboard D. Builders Hardware Manufacturers Association (BHMA): A156.9-03 Cabinet Hardw
14、are A156.11-04 . Cabinet Locks A156.16-02 . Auxiliary Hardware E. Hardwood Plywood and Veneer Association (HPVA): HP1-09 . Hardwood and Decorative Plywood F. National Particleboard Association (NPA): A208.1-99 Wood Particleboard G. American Wood-Preservers Association (AWPA): AWPA C1-03 . All Timber
15、 Products Preservative Treatment by Pressure Processes H. Architectural Woodwork Institute (AWI): AWI-99 . Architectural Woodwork Quality Standards and Quality Certification Program I. National Electrical Manufacturers Association (NEMA): LD 3-05 High-Pressure Decorative Laminates J. U.S. Department
16、 of Commerce, Product Standard (PS): PS20-05 American Softwood Lumber Standard K. Military Specification (Mil. Spec): MIL-L-19140E . Lumber and Plywood, Fire-Retardant Treated L. Federal Specifications (Fed. Spec.): A-A-1922A Shield Expansion A-A-1936 . Contact Adhesive FF-N-836D Nut, Square, Hexago
17、n Cap, Slotted, Castle FF-S-111D(1) . Screw, Wood MM-L-736(C) Lumber, Hardwood PART 2 - PRODUCTS 2.1 LUMBER A. Grading and Marking: 1. Lumber shall bear the grade mark, stamp, or other identifying marks indicating grades of material. Provided by IHSNot for ResaleNo reproduction or networking permitt
18、ed without license from IHS-,-,-05-10 06 20 00 - 4 2. Such identifying marks on a material shall be in accordance with the rule or standard under which the material is produced, including requirements for qualifications and authority of the inspection organization, usage of authorized identification
19、, and information included in the identification. 3. The inspection agency for lumber shall be approved by the Board of Review, American Lumber Standards Committee, to grade species used. B. Sizes: 1. Lumber Size references, unless otherwise specified, are nominal sizes, and actual sizes shall be wi
20、thin manufacturing tolerances allowed by the standard under which product is produced. 2. Millwork, standing and running trim, and rails: Actual size as shown or specified. C. Hardwood: MM-L-736, species as specified for each item. D. Softwood: PS-20, exposed to view appearance grades: 1. Use C sele
21、ct or D select, vertical grain for transparent finish including stain transparent finish. 2. Use Prime for painted or opaque finish. E. Use edge grain Wood members exposed to weather. 2.2 PLYWOOD A. Softwood Plywood: 1. Prod. Std. 2. Grading and Marking: a. Each sheet of plywood shall bear the mark
22、of a recognized association or independent inspection agency that maintains continuing control over the quality of the plywood. b. The mark shall identify the plywood by species group or identification index, and shall show glue type, grade, and compliance with PS1. 3. Plywood, 13 mm (1/2 inch) and
23、thicker; not less than five ply construction, except 32 mm (1-1/4 inch) thick plywood not less than seven ply. 4. Plastic Laminate Plywood Cores: a. Exterior Type, and species group. b. Veneer Grade: A-C. 5. Shelving Plywood: a. Interior Type, any species group. b. Veneer Grade: A-B or B-C. 6. Other
24、: As specified for item. B. Hardwood Plywood: 1. HPVA: HP.1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 5 2. Species of face veneer shall be as shown or as specified in connection with each particular item. 3. Inside of Building:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0620002010FINISHCARPENTRYPDF