VA 05 40 00-2011 COLD-FORMED METAL FRAMING.pdf
《VA 05 40 00-2011 COLD-FORMED METAL FRAMING.pdf》由会员分享,可在线阅读,更多相关《VA 05 40 00-2011 COLD-FORMED METAL FRAMING.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、07-11 05 40 00 - 1 SECTION 05 40 00 COLD-FORMED METAL FRAMING SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: A. This section specifies materials an
2、d services required for installation of cold-formed steel, including tracks and required accessories as shown and specified. This Section includes the following: SPEC WRITER NOTE: Adjust the list below to suit the Project. 1. Exterior load-bearing steel stud walls. 2. Interior load-bearing steel stu
3、d walls. 3. Exterior non-load-bearing steel stud curtain wall. 4. Steel joists. 5. Steel trusses. 1.2 RELATED WORK: A. Structural steel framing: Section 05 12 00, STRUCTURAL STEEL FRAMING. B. Open web steel joists: Section 05 21 00, STEEL JOIST FRAMING. C. Non-load-bearing metal stud framing assembl
4、ies: Section 09 22 16, NON-STRUCTURAL METAL FRAMING. D. Gypsum board assemblies: Section 09 29 00, GYPSUM BOARD. 1.3 DESIGN REQUIREMENTS: A. Design steel in accordance with American Iron and Steel Institute Publication “Specification for the Design of Cold-Formed Steel Structural Members“, except as
5、 otherwise shown or specified. SPEC WRITER NOTE: Retain one of the two “Structural Performance” articles below. Retain the first article when the Architect provides cold-formed steel physical and structural properties. Retain the second article when the Provided by IHSNot for ResaleNo reproduction o
6、r networking permitted without license from IHS-,-,-07-11 05 40 00 - 2 fabricator is responsible for designing the metal framing. B. Structural Performance: Engineer, fabricate and erect cold-formed metal framing with the minimum physical and structural properties indicated. C. Structural Performanc
7、e: Engineer, fabricate, and erect cold-formed metal framing to withstand design loads within limits and under conditions required. 1. Design Loads: As indicated. 2. Design framing systems to withstand design loads without deflections greater than the following: SPEC WRITER NOTE: Deflection limits be
8、low are examples only. Select deflection limits as appropriate for wall, floor, and ceiling finish materials. a. Exterior Load-Bearing Walls: Lateral deflection of / 1/240 / / 1/360 / / 1/600 / of the wall height. b. Interior Load-Bearing Walls: Lateral deflection of / 1/240 / / 1/360 / of the wall
9、height. c. Exterior Non-load-Bearing Curtain wall: Lateral deflection of / 1/240 / / 1/360 / / 1/600 / / 1/720 / of the wall height. d. Floor Joists: Vertical deflection of / 1/240 / / 1/360 / of the span. e. Roof Trusses: Vertical deflection of / 1/240 / /1/360 / of the span. 3. Design framing syst
10、ems to provide for movement of framing members without damage or overstressing, sheathing failure, connection failure, undue strain on fasteners and anchors, or other detrimental effects when subject to a maximum ambient temperature change (range) of 67 degrees C (120 degrees F). 4. Design framing s
11、ystem to accommodate deflection of primary building structure and construction tolerances, and to maintain clearances at openings. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 05 40 00 - 3 5. Design exterior non-load-bearing curtain wall fra
12、ming to accommodate lateral deflection without regard to contribution of sheathing materials. 6. Engineering Responsibility: Engage a fabricator who assumes undivided responsibility for engineering cold-formed metal framing by employing a qualified professional engineer to prepare design calculation
13、s, shop drawings, and other structural data. 1.4 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: Shop and erection drawings showing steel unit layout, connections to supporting members, and information necessary to complete insta
14、llation as shown and specified. C. Manufacturers Literature and Data: Showing steel component sections and specifying structural characteristics. SPEC WRITER NOTE: Retain the paragraph below when cold-formed metal framing is indicated to withstand specific design loadings. D. For cold-formed metal f
15、raming indicated to comply with certain design loadings, include structural analysis data sealed and signed by the qualified professional engineer who was responsible for its preparation. 1.5 APPLICABLE PUBLICATIONS: A. Publications listed below form a part of this specification to extent referenced
16、. Publications are referenced in text by basic designation only. B. American Iron and Steel Institute (AISI): Specification and Commentary for the Design of Cold-Formed Steel Structural Members (1996) C. American Society of Testing and Materials (ASTM): A36/A36M-08 Standard Specifications for Carbon
17、 Structural Steel Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 05 40 00 - 4 A123/A123M-09 Standard Specifications for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products A153/A153M-09 Standard Specifications for Zinc Coating (Hot-D
18、ip) on Iron and Steel Hardware A307-10 Standard Specifications for Carbon Steel Bolts and Studs A653/A653M-10 Standard Specifications for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process C1107/C1107M-08 Standard Specifications for Packaged Dry, Hy
19、draulic-Cement Grout (Non-shrink) E488-96(R2003) . Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements E1190-95(R2007) Standard Test Methods for Strength of Power-Actuated Fasteners Installed in Structural Members D. American Welding Society (AWS): D1.3/D1.3M-08 Structural
20、 Welding Code-Sheet Steel E. Military Specifications (Mil. Spec.): MIL-P-21035B . Paint, High Zinc Dust Content, Galvanizing Repair PART 2 - PRODUCTS 2.1 MATERIALS: SPEC WRITER NOTE: Select G60 or G90 coating. The Brick Industry Association recommends G90 for stud backup for brick veneer application
21、s. A. Sheet Steel for joists, studs and accessories 16 gage and heavier: ASTM A653, structural steel, zinc coated / G60 / / G90 /, with a yield of 340 MPa (50 ksi) minimum. B. Sheet Steel for joists, studs and accessories 18 gage and lighter: ASTM A653, structural steel, zinc coated / G60 / / G90 /,
22、 with a yield of 230 MPa (33 ksi) minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 05 40 00 - 5 C. Galvanizing Repair Paint: MIL-P-21035B. SPEC WRITER NOTE: Retain grout when concrete or masonry substrates require leveling prior to sett
23、ing track or prefabricated assemblies. D. Nonmetallic, Non-shrink Grout: Premixed, nonmetallic, noncorrosive, nonstaining grout containing selected silica sands, Portland cement, shrinkage-compensating agents, plasticizing and water-reducing agents, complying with ASTM C1107, with fluid consistency
24、and a 30 minute working time. 2.2 WALL FRAMING: SPEC WRITER NOTE: Retain this article when steel studs are required. Select the steel thickness as required. Sequence corresponds to 20 gage, 18 gage, 16 gage, 14 gage, and 12 gage thicknesses. A. Steel Studs: Manufacturers standard C-shaped steel stud
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0540002011COLDFORMEDMETALFRAMINGPDF