VA 05 36 00-2011 COMPOSITE METAL DECKING.pdf
《VA 05 36 00-2011 COMPOSITE METAL DECKING.pdf》由会员分享,可在线阅读,更多相关《VA 05 36 00-2011 COMPOSITE METAL DECKING.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、07-11 05 36 00 - 1 SECTION 05 36 00 COMPOSITE METAL DECKING SPEC WRITER NOTE: Delete between / - / if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 GENERAL 1.1 DESCRIPTION: This section specifies material and serv
2、ices required for installation of composite steel decking including / shear connector studs and / miscellaneous closures required to prepare deck for concrete placement as shown and specified. 1.2 RELATED WORK: Materials testing and inspection during construction: Section 01 45 29, TESTING LABORATOR
3、Y SERVICES. 1.3 DESIGN REQUIREMENTS: A. Design steel decking in accordance with American Iron And Steel Institute publication “Specifications for the Design of Cold Formed Steel Structural Members“, except as otherwise shown or specified. B. Design all elements with the latest published version of a
4、pplicable codes. 1.4 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: Shop and erection drawings showing decking unit layout, connections to supporting members, and information necessary to complete the installation as shown and s
5、pecified, including supplementary framing, cant strips, cut openings, special jointing or other accessories. Show welding, side lap, closure, deck reinforcing and closure reinforcing details. Show openings required for work of other trades, including openings not shown on structural drawings. Indica
6、te where temporary shoring is required to satisfy design criteria. C. Manufacturers Literature and Data: Showing steel decking section properties and specifying structural characteristics as specified herein. D. Manufacturers written recommendations for: 1. Shape of decking section to be used. 2. Cl
7、eaning of steel decking prior to concrete placement. E. Test Report - Establishing structural characteristics of composite concrete and steel decking system. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 05 36 00 - 2 F. Test Report - Stud bas
8、e qualification. G. Welding power setting recommendation by shear stud manufacturer. H. Shear Stud Layouts: Submit drawings showing the number, pattern, spacing and configuration of the shear studs for each beam and girder. I. Certification: For each type and gauge of metal deck supporting concrete
9、slab or fill, furnish certification of the specified fire ratings. Certify that the units supplied are U.L. listed as a “Steel Floor and Form Unit”. 1.5 QUALITY ASSURANCE: SPEC WRITER NOTE: Delete below when UL listed floor deck units not required. Review required ratings with Architect. Confirm loc
10、ations for ratings and where deck will need spray applied fireproofing. Underwriters Label: Provide metal floor deck units listed in Underwriters Laboratories “Fire Resistance Directory”, with each deck unit bearing the UL label and marking for specific system detailed. 1.6 APPLICABLE PUBLICATIONS:
11、A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only. Refer to the latest edition of all referenced Standards and codes. B. American Iron and Steel Institute (AISI): Specification and Commentary for the Des
12、ign of Cold-Formed Steel Structural Members (Latest Edition). C. American Society of Testing and Materials (ASTM): A36/A36M-08 Standard Specification for Carbon Structural Steel A108-07 Standard Specification for Steel Bars, Carbon, Cold Finished, Standard Quality A653/A653M-10 Standard Specificatio
13、n for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvanized) by the Hot-Dip Process D. American Institute of Steel Construction (AISC): 1. Specification for Structural Steel Buildings Allowable Stress Design and Plastic Design (Latest Edition) 2. Load and Resistance Factor Desi
14、gn Specification for Structural Steel Buildings (Latest Edition) E. American Welding Society (AWS): D1.1/D1.1M-10 Structural Welding Code - Steel D1.3/D1.3M-08 Structural Welding Code - Sheet Steel E. Military Specifications (Mil. Spec.): Provided by IHSNot for ResaleNo reproduction or networking pe
15、rmitted without license from IHS-,-,-07-11 05 36 00 - 3 MIL-P-21035B . Paint, High Zinc Dust Content, Galvanizing Repair PART 2 - PRODUCTS SPEC WRITER NOTE: For galvanizing treatment use coating class G60 for normal conditions, and G90 for extreme exposure (salt air, etc.) 2.1 MATERIALS: A. Steel De
16、cking and all Flashings: ASTM A653, Structural Quality / suitable for shear stud weld-through techniques /. B. Galvanizing: ASTM A653, / G90 / G60 /. C. Shear connector studs: ASTM A108, Grades 1015-1020, yield 350 Mpa (50,000 psi) minimum, tensile strength - 400 Mpa (60,000 psi) minimum, reduction
17、of area 50 percent minimum. Studs of uniform diameter; heads shall be concentric and normal to shaft; stud, after welding free from any substance or defect which would interfere with its function as a shear connector. Studs shall not be painted or galvanized. Size of studs shall be as shown on drawi
18、ngs. Studs manufactured by a company normally engaged in the manufacturer of shear studs and can furnish equipment suitable for weld-through installation of shear studs. D. Galvanizing Repair Paint: Mil. Spec. MIL-P-21035B. E. Miscellaneous Steel Shapes: ASTM A36. F. Welding Electrode: E60XX minimum
19、. G. Sheet Metal Accessories: ASTM A653, galvanized, unless noted otherwise. Provide accessories of every kind required to complete the installation of metal decking in the system shown. Finish sheet metal items to match deck including, but not limited to, the following items: 1. Metal Cover Plates:
20、 For end-abutting deck units, to close gaps at changes in deck direction, columns, walls and openings. Same quality as deck units but not less than 1.3 mm (18 gauge) sheet steel. 2. Continuous sheet metal edging: at openings and concrete slab edges. Same quality as deck units but not less than 1.3 m
21、m (18 gauge) steel. Side and end closures supporting concrete and their attachment to supporting steel shall be designed by the manufacturer to safely support the wet weight of concrete and construction loads. The deflection of cantilever closures shall be limited to 3 mm (1/8 inch) maximum. 3. Meta
22、l Closure Strips: For openings between decking and other construction, of not less than 1.3 mm (18 gauge) sheet steel of the same quality as the deck units. Form to the configuration required to Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 0
23、5 36 00 - 4 provide tight-fitting closures at open ends of flutes and sides of decking. 4. Seat angles for deck: Where a beam does not frame into a column. 2.2 REQUIREMENTS: A. Steel decking depth, gage, and section properties to be as shown. Provide edges of deck with vertical interlocking male and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0536002011COMPOSITEMETALDECKINGPDF