1、09-11 03 51 13 - 1 SECTION 03 51 13 CEMENTITIOUS WOOD FIBER DECKS SPEC WRITE NOTES: 1. Delete between / _/ if not applicable to project. 2. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 3. Listed by UL as structural cement-fiber units, and two man
2、ufacturers. PART 1 - GENERAL 1.1 DESCRIPTION Section specifies structural cement-fiber units (planks) for roof deck / and acoustical panels /. 1.2 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Cement-fiber unit deck installat
3、ion details and anchorage. 2. Show primary frames members and purlins with subpurline and opening framing. C. Manufacturers Literature and Data: 1. Cement-fiber units showing compliance with specifications including anchorage items and Installation instructions. 2. Subpurling. 3. Grout. D. Certifica
4、tes: Stating cement-fiber units meet fire hazard classification, wind uplift requirement, and “R“ values specified. 1.3 DELIVERY Deliver units to site labeled with manufacturers name, brand and contents. 1.4 STORAGE A. Store cement-fiber units and accessories in weathertight and dry storage facility
5、. B. Protect from damage from handling, water, weather, and construction operations before, during, and after installation. 1.5 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.
6、B. American Society for Testing and Materials (ASTM): A36/A36M-08 Structural Steel Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 03 51 13 - 2 A653/A653M-10 Steel Sheet, Zinc Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the
7、Hot-Dip Process C144-04 Aggregates for Masonry Mortar C150-09 Portland Cement C177-10 Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded Hot-Plate Apparatus C423-09 Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method C494-1
8、0 Chemical Admixtures for Concrete C1289-10 . Faced Rigid Cellular Polyisocynurate Thermal Insulation Board E84-10 . Surface Burning Characteristics of Building Materials E119-10 Fire Tests of Building Construction and Materials E1264-08 . Classification for Acoustical Ceiling Products F1667-10 . Dr
9、iven Fasteners: Nails, Spikes and Staples C. American Welding Society (): D1.1-10 Structural Welding Code Steel D. Factory Mutual Engineering and Research Corporation (FM): Annual issue . Approval Guide Building Materials E. Underwriters Laboratories, Inc. (UL): Annual issue . Building Materials Dir
10、ectory Annual issue . Fire Resistance Directory F. Warnock Heresy (WH): Annual issue . Certification Listings G. Federal Specifications (Fed. Spec.): FF-S-107C(2) . Screws, Tapping and Drive SPEC WRITER NOTES: 1. Make material requirements agree with applicable requirements specified in the referenc
11、ed Applicable Publications. 2. Update and specify only that which applies to the project. 3. Coordinate roof deck design with structural Engineer to show assembly required and section editing. 4. Coordinate details when units are used for acoustical panels. PART 2 - PRODUCTS 2.1 MATERIALS A. Portlan
12、d Cement: ASTM C150, Type I or III. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 03 51 13 - 3 B. Chemical Admixtures: ASTM C494, type as required by unit manufacturer. C. Aggregate: ASTM C144. D. Wood fiber: 1. Wood species: Unit manufacture
13、rs standard softwood. 2. Shredded into strips; random lengths unit manufacturers standard specifications. 3. Treated for fire resistance. E. Fasteners: 1. Nails: ASTM F1667, galvanized, roof type with integral 25 mm (1-inch) washers length to provide 76 mm (1-1/2-inches) penetration into wood suppor
14、t, type as required by unit manufacturer. 2. Screws: Fed. Spec FF-S-107 type as required by unit manufacturer. a. Provide 25 mm (1-inch) wide washers when screw retains unit. b. Provide 26 mm (1-1/2-inch) minimum penetration into wood. SPEC WRITER NOTE: Specify physical properties of bulb tees used
15、on project. Design deflection: 1/360 of span. F. Bulb-Tee Subpurlins: 1. Fabricated from ASTM A36 steel. 2. Minimum flange bearing area each side: 50 mm (1-inch). 3. Rust inhibiting paint finish, manufacturers standard. 4. Properties: a. Minimum weight per 0.304 mm (lineal foot: _ Kg (_ pounds) b. H
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0351132011CEMENTITIOUSWOODFIBERDECKSPDF