1、07-11 02 82 13.21 - i SECTION 02 82 13.21 ASBESTOS ROOFING ABATEMENT TABLE OF CONTENTS PART 1 - GENERAL 1 1.1 SUMMARY OF THE WORK . 1 1.1.1 CONTRACT DOCUMENTS AND RELATED REQUIREMENTS . 1 1.1.2 EXTENT OF WORK 2 1.1.3 RELATED WORK 2 1.1.4 TASKS . 2 1.1.5 ABATEMENT CONTRACTOR USE OF PREMISES 2 1.2 VAR
2、IATIONS IN QUANTITY 3 1.3 STOP ASBESTOS REMOVAL . 3 1.4 DEFINITIONS . 4 1.4.1 GENERAL . 4 1.4.2 GLOSSARY 4 1.4.3 REFERENCED STANDARDS ORGANIZATIONS . 10 1.5 APPLICABLE CODES AND REGULATIONS . 11 1.5.1 GENERAL APPLICABILITY OF CODES, REGULATIONS, AND STANDARDS . 11 1.5.2 CONTRACTOR RESPONSIBILITY 12
3、1.5.3 FEDERAL REQUIREMENTS . 12 1.5.4 STATE REQUIREMENTS . 12 1.5.5 LOCAL REQUIREMENTS . 13 1.5.6 STANDARDS 13 1.5.7 EPA GUIDANCE DOCUMENTS . 13 1.5.8 NOTICES 13 1.5.9 PERMITS/LICENSES . 13 1.5.10 POSTING AND FILING OF REGULATIONS . 14 1.5.11 VA RESPONSIBILITIES . 14 1.5.12 SITE SECURITY . 14 1.5.13
4、 EMERGENCY ACTION PLAN AND ARRANGEMENTS 15 1.5.14 PRE-START MEETING . 15 1.6 PROJECT COORDINATION . 16 1.6.1 PERSONNEL 16 1.7 RESPIRATORY PROTECTION . 17 1.7.1 GENERAL - RESPIRATORY PROTECTION PROGRAM . 17 1.7.2 RESPIRATORY PROTECTION PROGRAM COORDINATOR . 18 Provided by IHSNot for ResaleNo reproduc
5、tion or networking permitted without license from IHS-,-,-07-11 02 82 13.21 - ii 1.7.3 SELECTION AND USE OF RESPIRATORS . 18 1.7.4 MINIMUM RESPIRATORY PROTECTION . 18 1.7.5 MEDICAL WRITTEN OPINION 18 1.7.6 RESPIRATOR FIT TEST 18 1.7.7 RESPIRATOR FIT CHECK . 18 1.7.8 MAINTENANCE AND CARE OF RESPIRATO
6、RS 18 1.8 WORKER PROTECTION 19 1.8.1 TRAINING OF ABATEMENT PERSONNEL 19 1.8.2 MEDICAL EXAMINATIONS . 19 1.8.3 PERSONAL PROTECTIVE EQUIPMENT 19 1.8.4 REGULATED AREA ENTRY PROCEDURE . 19 1.8.5 DECONTAMINATION PROCEDURE 19 1.8.6 REGULATED AREA REQUIREMENTS 19 PART 2 - PRODUCTS, MATERIALS AND EQUIPMENT
7、. 20 2.1 MATERIALS AND EQUIPMENT 20 2.1.1 GENERAL REQUIREMENTS (ALL ABATEMENT PROJECTS) 20 2.2 CONTAINMENT BARRIERS AND COVERINGS IN THE REGULATED AREA . 21 2.2.1 GENERAL 21 2.2.3 CONTROLLING ACCESS TO THE REGULATED AREA . 22 2.2.4 CRITICAL BARRIERS 22 2.2.5 SECONDARY BARRIERS: 22 2.2.6 EXTENSION OF
8、 THE REGULATED AREA 22 2.3 MONITORING, INSPECTION AND TESTING . 22 2.3.1 GENERAL 22 2.3.2 SCOPE OF SERVICES OF THE VPIH/CIH CONSULTANT . 23 2.3.3 MONITORING, INSPECTION AND TESTING BY CONTRACTOR CPIH/CIH 24 2.4 STANDARD OPERATING PROCEDURES 25 2.5 SUBMITTALS . 25 2.5.1 PRE-START MEETING SUBMITTALS .
9、 25 2.5.2 SUBMITTALS DURING ABATEMENT 27 2.5.3 SUBMITTALS AT COMPLETION OF ABATEMENT 28 PART 3 - EXECUTION . 28 3.1 PRE-ABATEMENT ACTIVITIES . 28 3.1.1 PRE-ABATEMENT MEETING 28 3.1.2 PRE-ABATEMENT INSPECTIONS AND PREPARATIONS . 28 3.1.3 PRE-ABATEMENT CONSTRUCTION AND OPERATIONS 29 3.2 REGULATED AREA
10、 PREPARATIONS 29 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 02 82 13.21 - iii 3.2.1 OSHA DANGER SIGNS 29 3.2.2 SHUT DOWN - LOCK OUT ELECTRICAL 29 3.2.3 SHUT DOWN - LOCK OUT HVAC 30 3.2.4 SANITARY FACILITIES 30 3.2.6 PRE-CLEANING MOVABLE OB
11、JECTS . 30 3.2.7 PRE-CLEANING FIXED OBJECTS . 30 3.2.8 PRE-CLEANING SURFACES IN THE REGULATED AREA 31 3.3 CONTAINMENT BARRIERS AND COVERINGS FOR THE REGULATED AREA 31 3.3.1 GENERAL 31 3.3.2 PREPARATION PRIOR TO SEALING OFF . 31 3.3.3 CONTROLLING ACCESS TO THE REGULATED AREA . 31 3.3.4 CRITICAL BARRI
12、ERS 31 3.3.5 EXTENSION OF THE REGULATED AREA 32 3.4 REMOVAL OF CLASS II ROOFING: . 32 3.4.1 GENERAL 32 3.5 DISPOSAL OF CLASS ii WASTE MATERIAL: . 34 3.5.1 GENERAL 34 3.6 PROJECT DECONTAMINATION 34 3.6.1 GENERAL 34 3.6.2 REGULATED AREA CLEARANCE . 34 3.6.3 WORK DESCRIPTION . 34 3.6.4 PRE-DECONTAMINAT
13、ION CONDITIONS . 34 3.6.5. CLEANING: . 34 3.7 VISUAL INSPECTION AND AIR CLEARANCE TESTING 35 3.7.1 GENERAL 35 3.7.2 VISUAL INSPECTION 35 3.7.3 AIR CLEARANCE TESTING 35 3.7.4 FINAL AIR CLEARANCE PROCEDURES . 35 3.8 ABATEMENT CLOSEOUT AND CERTIFICATE OF COMPLIANCE . 36 3.8.1 COMPLETION OF ABATEMENT WO
14、RK . 36 3.8.2 CERTIFICATE OF COMPLETION BY CONTRACTOR 36 3.8.3 WORK SHIFTS 36 ATTACHMENT #1 37 ATTACHMENT #2 Error! Bookmark not defined. ATTACHMENT #3 Error! Bookmark not defined. ATTACHMENT #4 Error! Bookmark not defined. Provided by IHSNot for ResaleNo reproduction or networking permitted without
15、 license from IHS-,-,-07-11 02 82 13.21 - 1 INSTRUCTIONS TO ARCHITECT/ENGINEER AND INDUSTRIAL HYGIENE CONSULTANT SECTION 02 82 13.21 ASBESTOS ROOFING ABATEMENT SPECIFICATIONS 1. These specifications provide general guidance to personnel given the task of designing and executing a Class II roofing ab
16、atement project. Each abatement is a unique situation and therefore must be tailored for that project. This specification incorporates current regulatory requirements and current best abatement practices, procedures and technology. The Architect/Engineer and/or the Industrial Hygiene consultants may
17、 provide additional specification additions or deletions to this specification that, in their professional judgment, will ensure a safe and effective approach to a specific abatement project while maintaining compliance with applicable regulations and VA policy. Any changes must be clearly marked on
18、/attached to this document prior to finalization of the specification so that the changes will be adequately considered in the review process by the VA. 2. These specifications are to be used in conjunction with Contractor selection criteria; special instructions package; and general construction pr
19、ovisions. 3. Paragraphs that are not preceded by a number code are indented as instructions to the specifications writer and identified by the notation “Spec Writer Notes“. These paragraphs must be deleted from the final document. 4. Within the text of the specifications, there may be optional proce
20、dures which the specification writer could include in the final specification. Procedures which are not chosen must be deleted by the specification writer. Optional text is shown by the notation (/text/). 5. The specification writer, VPIH/CPIH, CPIH/CIH, and A/E must be aware of and read the VA A/E
21、Quality Alert 07/09 since it details common errors in specification and contract documents for asbestos project. This would be especially helpful if a survey is being conducted prior to an abatement project. A full AHERA survey of the facility would be needed prior to renovation activities, however,
22、 if demolition of the facility is planned, a NESHAP survey of the facility would need to be performed. PART 1 - GENERAL 1.1 SUMMARY OF THE WORK 1.1.1 CONTRACT DOCUMENTS AND RELATED REQUIREMENTS Drawings, general provisions of the contract, including general and supplementary conditions and other Div
23、ision 01 specifications, shall apply to the work of this section. The contract documents show the work to be done under the contract and related requirements and conditions impacting the project. Related requirements and conditions include applicable codes and regulations, notices and permits, exist
24、ing site conditions and restrictions on use of the site, requirements for partial owner occupancy during the work, coordination with other work and the phasing of the work. In the event the Asbestos Abatement Contractor discovers a conflict in the contract documents and/or requirements or codes, the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA028213212011ASBESTOSROOFINGABATEMENTPDF