UOP 827-1981 APPARENT HYDROGEN SULFIDE IN AMINE SOLUTIONS.pdf
《UOP 827-1981 APPARENT HYDROGEN SULFIDE IN AMINE SOLUTIONS.pdf》由会员分享,可在线阅读,更多相关《UOP 827-1981 APPARENT HYDROGEN SULFIDE IN AMINE SOLUTIONS.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、APPARENT HYDROGEN SULFIDE IN AMINE SOLUTIONSUOP Method 827-81SCOPEA Control and a Precision method are used for the determination of apparent hydrogen sulfide in aminesolutions. Hydrogen sulfide is determined by oxidation with standard iodine solution in an acid medium.Thiosulfate, if present, is al
2、so titrated and is included as apparent H2S in the calculation. Thiosulfate may bedetermined by using UOP Method 818, and the value thus obtained subtracted from the apparent H2Sconcentration. The lower limit of detection is approximately 25 grains/gallon.OUTLINE OF METHODControl MethodFor plant con
3、trol work with lean amine solutions containing low levels of hydrogen sulfide, a directtitration method may be used. A portion of the amine sample is pipeted into water, acidified with HCl, andimmediately titrated with a standard iodine solution using starch solution as the indicator.Precision Metho
4、dFor solutions containing more than 100 grains of H2S per gallon, or where better precision is required, aportion of the amine sample is pipeted into an acidified water solution containing an excess of standardiodine solution. The excess iodine is back titrated with standard sodium thiosulfate solut
5、ion using starchsolution as the indicator.APPARATUSBalance, torsion or top loading type, 500 g capacity, capable of weighing to 0.01 gBeakers, 100- and 250-mLBuret, 50-mL (2 required) with Teflon stopcock, 0.1-mL subdivisionsCylinder, graduated, 50-mL, glass, 1.0-mL subdivisionsFlask, Erlenmeyer, 25
6、0-mLFlask, volumetric, one-liter (2 required)IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TODETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH ANDSAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTI
7、LIZE THISPROCEDURE IN THE MANNER PRESCRIBED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS(MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED INTHIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTIONEQUIPMENT (PPE). COPYRIGHT
8、1981 UOP LLCALL RIGHTS RESERVEDUOP Methods are available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken PA 19428-2959,United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service atserviceastm.org, 610.832.955
9、5 FAX, or 610.832.9585 PHONE.2 of 4827-81Flask, volumetric, 100-mLHot plate, adjustable heat, Sargent-Welch Scientific Co., Cat. No. S-41000A, or equivalentPipet manipulator, Sargent-Welch Scientific Co., Cat. No. S-69793, or equivalentPipets, serological, calibrated for blow-out, 1-, 5- and 10-mL c
10、apacity, Sargent-Welch Scientific Co., Cat.Nos. S-69625-C, G and H, or equivalentStirrer, magnetic, with Teflon covered stirring bar, Sargent-Welch Scientific Co., Cat. No. S-76490, orequivalentREAGENTSAll reagents shall conform to the specifications established by the Committee on Analytical Reagen
11、ts ofthe American Chemical Society, when such specifications are available, unless otherwise specified.References to water mean deionized or distilled water.Hydrochloric acid, concentratedIodine solution, 0.05 M. To prepare, dissolve 25 g of potassium iodide in 200 mL of water. Warm slightlyto disso
12、lve. Cool and add 12.69 g of iodine crystals. Stir the solution to dissolve the reagents andtransfer quantitatively to a one-liter volumetric flask. Dilute to volume with water. Store in an amberbottle. Standardize against the 0.1 M sodium thiosulfate. If samples are analyzed infrequently, theiodine
13、 solution must be standardized prior to use.Methyl orange indicator solution, 0.1 wt-% concentration. Dissolve 0.1 g of methyl orange in 100 mL ofwater.Salicylic acidSodium thiosulfate solution, 0.1 M. To prepare, dissolve 24.82 g of sodium thiosulfate (Na2S2O3-5H2O) in200 mL of warm water. Quantita
14、tively transfer to a one-liter volumetric flask, cool, and dilute tovolume with water. Standardize in any acceptable fashion such as by the iodine or arsenious oxidetechnique.Starch, arrowroot, Leco Corp., Cat. No. 501-061, or equivalentStarch solution. Stir with a glass rod while slowly adding 0.25
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP8271981APPARENTHYDROGENSULFIDEINAMINESOLUTIONSPDF

链接地址:http://www.mydoc123.com/p-1074551.html