UOP 699-2009 Sodium in Liquefied Petroleum Gas by ICP-OES or AAS.pdf
《UOP 699-2009 Sodium in Liquefied Petroleum Gas by ICP-OES or AAS.pdf》由会员分享,可在线阅读,更多相关《UOP 699-2009 Sodium in Liquefied Petroleum Gas by ICP-OES or AAS.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1969, 1991, 2009 UOP LLC. All rights r
3、eserved. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or
4、610.832.9585 PHONE. Sodium in Liquefied Petroleum Gas by ICP-OES or AAS UOP Method 699-09 Scope This method is for determining the concentration of sodium (Na) as dissolved and suspended sodium compounds in liquefied petroleum gas (LPG) in the range of 0.1 to 10 mg/kg (mass-ppm) sodium. After sample
5、 preparation, either Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES, or ICP) or Atomic Adsorption Spectroscopy (AAS) can be utilized to determine the sodium concentration. References ASTM Specification D1193, Reagent Water, www.astm.org UOP Method 516, “Sampling of Gasolines, Dist
6、illate Fuels and C3-C4Fractions” UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method A clean, dry pressure vessel is utilized to obtain a stream sample of liquefied petroleum gas (LPG). The entire contents of the pressure vessel are discharged into an uncovered, one
7、-liter, wide-mouth, plastic bottle containing a deionized water-methanol solution and allowed to evaporate. The empty pressure vessel is washed with a small quantity of the water-methanol solution and the washings are added to the sample in the one-liter open bottle. After the LPG has completely eva
8、porated, the sodium in the water-methanol solution is diluted to 100 mL with deionized water. The concentration of sodium is determined by ICP or AAS and the total concentration in the sample LPG is calculated. Apparatus References to catalog numbers and suppliers are included as a convenience to th
9、e method user. Other suppliers may be used. All plasticware is to be of low sodium content. In addition, all plasticware is to be thoroughly cleaned with deionized water, followed by washings with sodium-free acetone, and dried. Balance, readability 0.1-mg Balance, 5000-g capacity, readability 0.5-g
10、 2 of 7 699-09 Bottle, wash, polypropylene, 500-mL, VWR, Cat. No. 16651-904 Bottle, wide-mouth, Teflon FEP, 1000-mL, VWR, Cat. No. 16128-535. The bottle specified is resistant to temperature extremes and the solvents used in this method. It is also low in metals content and easy to clean. If alterna
11、tive containers are used, they must possess equivalent properties. Bottles, polypropylene, 1000- and 4000-mL, VWR, Cat. Nos. 16067-124 and 16067-168, respectively Bucket, polypropylene, 10.4-L capacity, VWR, Cat. No. 17306-005 Clamp, 3-prong, VWR, Cat. No. 21573-265, to hold the chromatographic colu
12、mn (2 required) Clamp, chain, VWR, Cat. No. 21573-275, and clamp holder, VWR, Cat. No. 12621-250, to hold the cylinder (2 required) Column, chromatographic, 19-mm ID, 300-mm length, with integral reservoir, VWR, Cat. No. 17810-19300 Cylinders, graduated, polypropylene, 10-, 50- and 100-mL, VWR, Cat.
13、 Nos. 65000-000, -004, and -006, respectively Flasks, volumetric, polypropylene, 100- and 1000-mL, VWR, Cat. Nos. 29615-007 and -062, respectively (several of each required) Funnel, polypropylene, 55-mm diameter, VWR, Cat. No. 30253-049 Hood, laboratory Hose connector, Swagelok, Cat. No. SS-4-HC-7-4
14、 Pipets, volumetric, Class A, 5-, 10-, and 50-mL, VWR, Cat. Nos. 89003-348, -350, and -366, respectively Pipet filler, VWR, Cat. No. 54397-053 Pressure vessel, cylinder, type 304 stainless steel, high pressure, 12,400 kPa gauge (1800 psig) maximum working pressure, 1000-mL capacity, Swagelok, Cat. N
15、o. 304L-HDF4-1000. Equip the cylinder with 2 stainless steel valves, Swagelok, Cat. No. SS-16DKM4, and caps, B-4-CP. Assemble and pressure test the vessel before use. Regulators, as required for gases for spectrophotometer used Spectrophotometer, ICP or AAS: Spectrophotometer, ICP, computer controll
16、ed, having sufficient resolving power and dispersion to separate the analytical lines in the 160-800 nm region. The computer must be capable of performing background corrections, blank corrections, and weight/volume and dilution corrections. A commercial grating spectrometer with a band pass of 0.01
17、8 nm or less in the first order is satisfactory. PerkinElmer Optima 5300 V Spectrophotometer, AAS, computer controlled, with hollow cathode lamp for sodium. The computer must be capable of performing background corrections, blank corrections, and weight/volume and dilution corrections. PerkinElmer A
18、nalyst 800. Support stand, VWR, Cat. No. 60100-105 Vacuum pump, or house vacuum Wire, copper, for grounding, 16-gauge, VWR, Cat. No. 66248-029 3 of 7 699-09 Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be use
19、d. Acetone (2-propanone), reagent grade, VWR, Cat. No. BJ010-1 Acetone, sodium-free. Prepare one liter by percolating reagent grade acetone down-flow through a bed of Amberlyst No. 15 cation exchange resin loosely packed in a chromatographic column. Maintain a flow rate of approximately 10 mL/min. C
20、ollect the percolated effluent and store it in a clean, one-liter, polypropylene bottle. Replace the resin for each additional batch. Air, dry, for cylinder cleaning Gases, instrument, as required for the specific spectrophotometer used Ferric chloride, anhydrous, VWR, Cat. No. EM-FX0215-1 Gloves, d
21、isposable, nitrile, low ionic extractible, VWR, Cat. No. 40101-356 (size large) Hydrochloric acid, concentrated, VWR, Cat. No. AA87617-K4 Hydrochloric acid, inhibited. Dissolve 1% by mass of ferric chloride in a mixture of equal volumes of deionized water and concentrated hydrochloric acid. Ion exch
22、ange resin, Amberlyst No. 15, VWR, Cat. No. AAA44079-A1 Methanol, for spectroscopy, VWR, Cat. No. BJ230-4 Methanol, sodium-free. Prepare one liter by percolating spectroscopy grade methanol down-flow through a bed of Amberlyst No. 15 cation exchange resin loosely packed in a chromatographic column.
23、Maintain a flow rate of approximately 10 mL/min. Collect the percolated effluent and store it in a clean, one-liter, polypropylene bottle. Replace the resin for each additional batch. Potassium stock solution, 10,000-g/mL, SPEX, Cat. No. PLK2-3X, used only for AAS analysis Scandium stock solution, 1
24、000-g/mL, SPEX, Cat. No. PLSC2-2X, used only for ICP analysis as an internal standard Scandium stock solution, 10-g/mL. Pipet 10 mL of 1000-g/mL scandium stock solution into a clean 1000-mL polypropylene volumetric flask, fill to volume with deionized water, cap and invert several times to thoroughl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP6992009SODIUMINLIQUEFIEDPETROLEUMGASBYICPOESORAASPDF

链接地址:http://www.mydoc123.com/p-1074525.html