UOP 516-2000 SAMPLING AND HANDLING OF GASOLINES DISTILLATE FUELS AND C3-C4 FRACTIONS.pdf
《UOP 516-2000 SAMPLING AND HANDLING OF GASOLINES DISTILLATE FUELS AND C3-C4 FRACTIONS.pdf》由会员分享,可在线阅读,更多相关《UOP 516-2000 SAMPLING AND HANDLING OF GASOLINES DISTILLATE FUELS AND C3-C4 FRACTIONS.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、SAMPLING AND HANDLING OF GASOLINES, DISTILLATE FUELS AND C3-C4FRACTIONS UOP Method 516-00 SCOPE This method is for the preparation and cleaning of sample cylinders, and for sampling techniques necessary to obtain an air-free sample of a liquid hydrocarbon. The procedures are applicable to liquefied
2、natural gases, high vapor pressure gasolines, various liquefied petroleum gases, air-unstable gasolines or other liquid hydrocarbon products that require rigorous exclusion of air. Sampling for the analysis of sulfur or other heteroatom compounds in C3-C4fractions requires a special cylinder or a sp
3、ecial cylinder preparation. An alternative to the sampling system and procedure is available as “Closed Sampling System”, UOP, PIC. If the sample is to be transported offsite, see NOTE 1. OUTLINE OF METHOD Cylinder cleaning and sampling techniques are specified to obtain a representative, air-free s
4、ample in a suitable container, e.g., a double-valved, stainless steel cylinder. For trace sulfur or other heteroatom compound analysis, a Silcosteelcoated cylinder is preferred. When coated cylinders are unavailable or impractical, a conventional cylinder is treated (pickled) to make it more stable
5、to sulfur compounds. The clean, leak-free cylinder is mounted vertically near the sampling point and connected to the plant sample line by steel tubing or pipe. The connecting lines are flushed with the sample. After line flushing, the sample is allowed to flow upward through the cylinder. Several v
6、olumes of sample are discarded before closing the valves of the cylinder. The cylinders that are used for collection are constructed to provide safe outage. APPARATUS References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used, unless sta
7、ted otherwise. Cylinder, C3-C4fractions, type 304 stainless steel, high pressure, 12,400 kPa, gauge (1800 psig) maximum working pressure, one-liter capacity, Whitey, Cat. No. 304L-HDF4-1000, or equivalent. Equip the cylinder with outage tube, Whitey, Cat. No. 304L-DTM4-F4-038, two stainless steel va
8、lves, Whitey, Cat. No. SS-16DKM4-F4, and two plugs, Whitey, Cat. No. SS-4-P, or equivalent. Smaller cylinders, such as 500-mL, may be used when large quantities of sample are not required. IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABIL
9、ITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIBED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSD
10、S) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1966,1983,1987, 2000 UOP LLC ALL RIGHTS RESERVED UOP Methods are available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consho
11、hocken PA 19428-2959, United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE. 2 of 12 516-00 Cylinder, C3-C4fractions, Silcosteel coated, for trace sulfur and other applications
12、which require a more inert surface than stainless steel, 1000 mL, Restek, Cat. No. 24275. Equip the cylinder with two Silcosteel coated valves, Restek, Cat. No. 24278, an outage tube, Whitey, Cat. No. 304L-DTM4-F4-038, and two caps, Whitey, Cat. No. SS-4-CP. Ship the outage tube to Restek for Silcos
13、teel coating, Restek, Cat. No. 54852. Caustic materials and strong acids will damage the Silcosteel surface. Samples and cleaning procedures must be caustic and acid free. Cylinder, gasoline and distillate fuels, type 304 stainless steel, 690 kPa, gauge (100 psig) maximum working pressure, Code No.
14、2, 28-L (7-gal) capacity, with dip tubes, equipped with 2 stainless steel valves. The cylinder without valves is available from Alloy Products, or equivalent. Valves are available from Whitey, Cat. No. SS-1KF4, or equivalent. The cylinder, as received, will be equipped with a long dip tube; the shor
15、t dip tube, made from 1/4-inch OD stainless steel, must be fabricated and welded to the valve coupling extending into the cylinder approximately 14 cm. Air-free samples of gasoline or distillate fuel oils to be used for treating, oxidation or corrosion studies are typically taken in this cylinder. C
16、AUTION: This cylinder cannot be used for samples having a vapor pressure above 275 kPa, gauge (40 psig) at 21C (70F). Cylinder Sampling Assembly, see Fig. 3, required for sampling gasolines or distillates Fittings, pressure-rated tubing or pipe made of stainless steel for use as transfer and manifol
17、d lines with appropriate valves, tees and unions or couplings of these materials. CAUTION. Do not use brass, aluminum or copper pipe, tubing, valves, unions, ferrules, or couplings. Grounding cable, heavy gauge wire or cable connected to a water pipe or to a rod driven into the ground, according to
18、local codes, having a suitable spring clamp to attach it to the metal cylinder; necessary to prevent explosion due to static electricity. Oven, gravity convection, capable of maintaining 150C, Fisher Scientific, Cat. No. 13-247-650G Pail, polyethylene, 13-L capacity, Fisher Scientific, Cat. No. 03-6
19、87-10 Regulator, nitrogen, delivery pressure 345-4480 kPa, gauge (50-650 psig), Matheson, Model No. 2-580, or equivalent Regulator, nitrogen, two-stage, delivery pressure 28-690 kPa, gauge (4-100 psig), Matheson, Model No. 3104-580, or equivalent Thermometer, Fisher Scientific, Cat. No. 15-077-2B Va
20、cuum pump, of sufficient capacity to evacuate the cylinder to the extent that the cleaning solution may be drawn into the cylinder REAGENTS References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Acetone, 99.5% minimum purity, Fisher
21、 Scientific, Cat. No. A949SK-4 Ferric chloride, Fisher Scientific, Cat. No. I89-500 3 of 12 516-00 Hydrochloric acid, 1:1, Fisher Scientific, Cat. No. LC15130-3 Isooctane, 99.5%, low residue, Fisher Scientific, Cat. No. O-301-4 Leak detector, solution, Leak-Check, Alltech Associates, Cat. No. 2025,
22、or equivalent Methanol, 99.8% minimum purity, Fisher Scientific, Cat. No. A408SK-4 Methylene chloride, 99.9%, low residue, Fisher Scientific, Cat. No. D151-4 Nitrogen, 99.99% minimum purity Pentane, 99%, low residue, Fisher Scientific, Cat. No. P399SK-4 Pickling solution. Prepare by dissolving 10 0.
23、1 g of ferric chloride in one liter of 1:1 hydrochloric acid. Steam, local supply TAM(toluene-acetone-methanol) solution. To prepare, mix equal portions of toluene, acetone and methanol. TI(toluene-isooctane) solution. To prepare, mix equal portions of toluene and isooctane. Toluene, 99.8% minimum p
24、urity, Fisher Scientific, Cat. No. T290SK-4 Water, deionized or distilled Water, tap, hot PREPARATION OF APPARATUS Cleaning and Drying Cylinders Proper preparation and cleaning of sample cylinders is of paramount importance. In no case may an improperly cleaned cylinder be used as a sample container
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP5162000SAMPLINGANDHANDLINGOFGASOLINESDISTILLATEFUELSANDC3C4FRACTIONSPDF

链接地址:http://www.mydoc123.com/p-1074500.html