UL SUBJECT 2889-2014 UL Outline for Investigation Electrically Operated Attic Lifts (Issue 1)《电动阁楼升降机的UL调查大纲 (议题1)》.pdf
《UL SUBJECT 2889-2014 UL Outline for Investigation Electrically Operated Attic Lifts (Issue 1)《电动阁楼升降机的UL调查大纲 (议题1)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2889-2014 UL Outline for Investigation Electrically Operated Attic Lifts (Issue 1)《电动阁楼升降机的UL调查大纲 (议题1)》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 5, 20141UL 2889Outline of Investigation for Electrically Operated Attic LiftsIssue Number: 1December 5, 2014Summary of TopicsThis first issue of the Outline of Investigation for Electric
2、ally OperatedAttic Lifts, UL 2889, covers electrical motor operated attic lifts.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, a
3、nd rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 5, 2014UL 28892No Text on This PageUL C
4、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Glossary .53 Units of Measurement .64 Components 65 Undated References 6CONSTRUCTION6 General 67 Runway 77.1 General .77.2 Minimum Clearance .77.3 Guarding of the runw
5、ay of a non-retractable lift 77.4 Guarding of the runway of a retractable lift 88 Guide Rails 89 Driving Means and Sheaves 810 Driving Machine Brakes 811 Suspension and Support Means .812 Platforms .813 Capacity, Speed, and Travel 914 Safety and Speed Governors 915 Terminal Stopping Devices 916 Oper
6、ating Devices and Control Equipment 916.1 General 916.2 Attendant Operation 1017 Structural Load .1018 Engineering Design Requirements 10PERFORMANCE19 General 1019.1 General .1019.2 Protruding Object Protection Test 1119.3 Underside of Platform Protective Device Test 1119.4 Underside of Platform For
7、ce Sensitive Safety Surface Test 1219.5 Underside of Platform Bellows (or Similar Device) Test .1219.6 Maximum Speed Test 1219.7 Self-locking Drive Test 1219.8 Capacity Test .1319.9 Speed and Travel Test 1319.10 Normal Terminal Stopping Devices Test .1319.11 Attendant Operating Devices Test .14RATIN
8、G20 General 14MARKINGDECEMBER 5, 2014 UL 2889 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL21 General 1422 Installation Instructions 15DECEMBER 5, 2014UL 28894UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION W
9、ITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline of investigation covers electrically operated attic lifts for use only by non-mobility impairedpersons. This outline of investigation does not cover attic lifts utilizing hydraulic driving means.1.2 This outline of investigation is intende
10、d for attic lifts operating from a voltage of 600 volts or less thatwill be installed in accordance with the National Electrical Code, NFPA 70 and the InternationalResidential Code only by persons trained by the attic lift manufacturer.1.3 This outline of investigation covers attic lifts intended to
11、 carry a single person or a load from theuppermost story of a one or two family residence or residential garage to an uninhabited attic, where theassembly penetrates only the floor of the attic and the ceiling of the uppermost story or garage.1.4 Vertical platform lifts intended for transportation o
12、f mobility impaired persons are covered by theSafety Standard for Platform Lifts and Stairway Chairlifts, ASME A18.1.1.5 Vertical platform lifts used exclusively for carrying materials between two or more landings(dumbwaiters) are covered by the Safety Code for Elevators and Escalators, ASME A17.1/C
13、SA B44.2 Glossary2.1 ATTENDANT CONTROL Controls that are not physically located on the platform.2.2 ATTIC An unfurnished and uninhabited space directly between the roof and uppermost story of aresidence.2.3 ATTIC ATTENDANT CONTROL Attendant controls physically located in the attic.2.4 GUIDE RAILS Pa
14、rts of an attic lift that maintain the platform in its intended position through itsintended motion during operation. Guide rails may be part of the suspension and support means as wellas provide protection from the driving machine. Guide rails may be a single column.2.5 NON-RETRACTABLE LIFT An elec
15、trically operated attic lift in which the attic lift guide rail, runway,beams, supports, and other framework (as applicable) are permanently installed in the uppermost story ofthe residence or garage.2.6 PLATFORM CONTROL Controls for the platform that are physically located on the platform,intended
16、to be used only by the person on the platform during its operation.2.7 RESIDENCE ATTENDANT CONTROL Attendant controls physically located in the uppermost story.2.8 RETRACTABLE LIFT An electrically operated attic lift in which the attic lift platform, guide rail,runway, beams, supports, and other fra
17、mework (as applicable) are intended to be fully retracted into theattic when the lift is not in use, leaving no part of the lift assembly between the floor and ceiling of theuppermost story of the residence.DECEMBER 5, 2014 UL 2889 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORD
18、ISTRIBUTION WITHOUT PERMISSION FROM UL2.9 UPPERMOST STORY The story of the residence directly below the attic, typically furnished andinhabited. For attic lifts installed in residential garages, the garage is considered the uppermost story,although it may not be furnished or inhabited.3 Units of Mea
19、surement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Components4.1 Except as indicated in 4.2, an electrical component of a product covered by this outline shall complywith the requirements for that component.4.2 A compo
20、nent is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.4.3 A component shall be used in accordance with its rat
21、ing established for the intended conditions ofuse.4.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be use
22、d only under those specific conditions.5 Undated References5.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 Attic lifts shall penetrate only the floor
23、 of the attic and ceiling of the uppermost story, and shall serviceonly the uppermost story and attic.DECEMBER 5, 2014UL 28896UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7 Runway7.1 General7.1.1 There shall be no pipes in the runway used f
24、or a liquid or gas that, if discharged, could cause bodilyharm or impair the proper electrical function of the lift.7.2 Minimum Clearance7.2.1 There shall be a minimum clearance of 2000 mm (79 in.) measured vertically from the platform toany member of the attic lift or building structure which does
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT28892014ULOUTLINEFORINVESTIGATIONELECTRICALLYOPERATEDATTICLIFTSISSUE1 电动 阁楼 升降机 UL 调查 大纲 议题

链接地址:http://www.mydoc123.com/p-1069371.html