UL SUBJECT 2808-2016 Outline of Investigation for Energy Monitoring Current Transformers (Issue 3).pdf
《UL SUBJECT 2808-2016 Outline of Investigation for Energy Monitoring Current Transformers (Issue 3).pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2808-2016 Outline of Investigation for Energy Monitoring Current Transformers (Issue 3).pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 10, 20161UL 2808Outline of Investigation for Energy Monitoring Current TransformersIssue Number: 3June 10, 2016Summary of TopicsThis third issue of the Outline of Investigation for Energy Mo
2、nitoringCurrent Transformers, UL 2808, includes revised requirements for thecase and potting material of current transformers.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines
3、of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 10, 2016UL 280
4、82No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .54 Undated References 55 Glossary .5CONSTRUCTION6 General 67 Case and Potting Materials .68 Spacings .89
5、Field wiring 1310 Burden Components 14PERFORMANCE11 Mold Stress Relief Test 1412 Dielectric Voltage-Withstand Test 1513 Lead Securement Test 1514 Permanence of Marking Test .1615 Temperature Test 1616 Permissible Limit Test .2017 Outdoor Use Submersion Test .2018 Outdoor Use Cold Impact Test .20MARK
6、INGS19 General 21INSTALLATION INSTRUCTIONS20 General 22ACCESSORIES21 Signal Gathering/Multiplexer Accessories 23APPENDIX AStandard for Components.A1JUNE 10, 2016 UL 2808 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 T
7、hese requirements cover open-type current transformers and their associated signal level combinerand/or multiplexer board accessories thereto intended for field installation within distribution and controlequipment such as panelboards, switchboards, industrial control equipment, and energymonitoring
8、/management equipment, to measure current on a branch circuit. Installation is in accordancewith the National Electrical Code, ANSI/NFPA 70. These requirements also cover Service Entranceenclosed-type current transformers intended for outdoor use.1.2 These current transformers are rated to measure c
9、urrent in a maximum 250 Vac, 600 Vac, or 1000Vac line-to-line circuits or in a maximum 1500 Vdc circuit. Transformers rated for use in an AC circuit mayalso be used in DC circuits that do not exceed the Vac rating.1.3 Current transformer conductor leads under the scope of this Outline are considered
10、 a Class 1 circuit,as defined by the National Electrical Code, ANSI/NFPA 70, and are intended to be installed with NFPA 70Chapter 3 wiring methods. Isolation for the user is provided at the termination.1.4 This Outline does not include investigation of the function of the controlled equipment.1.5 Th
11、ese current transformers have not been evaluated for accuracy or use with emergency controlsystems where the function of the control could affect safety.1.6 These current transformers are intended for use in an ambient temperature of 0 40C (32 104F)unless specifically indicated for use in other cond
12、itions.1.7 These current transformers are intended for use at altitudes up to 2000 meters (6562 ft) and in ahumidity tolerance of095percent, unless indicated for use in other conditions.1.8 Unless specifically evaluated and marked “Service Entrance”, these current transformers areevaluated for insta
13、llation within equipment on the load side of the service equipment overcurrent device.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline of Investigation shallcomply with the requirements for that component.2.2 A component is not required to comply with a sp
14、ecific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this Outline, orb) Is superseded by a requirement in this Outline.2.3 A component shall be used in accordance with its rating established for the intended conditi
15、ons ofuse.JUNE 10, 2016UL 28084UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited co
16、nditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any un
17、dated reference to a code or standard appearing in the requirements of this Outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purposes of this Outline, the following definitions apply.5.2 BURDEN COMPONENT A resistor or other component that
18、limits open circuit voltage of the currenttransformer.5.3 CLASS 1 CIRCUIT The portion of the wiring system between the load side of the overcurrent deviceor power-limited supply and the connected equipment.5.4 CLASS 2 CIRCUIT The portion of the wiring system between the load side of a Class 2 powers
19、ource and the connected equipment.5.5 OPEN-TYPE DEVICE A device that is not provided with a complete enclosure and is intended tobe placed in a suitable end-product enclosure.5.6 SERVICE ENTRANCE That portion of the installation between the service point and the line sideof the service equipment.Not
20、e: Service entrance correlates with Overvoltage Category IV, or CAT IV, as defined in IEC 60364 andIEC 60664-1.5.7 CONTROLLED ENVIRONMENT Also known as Pollution Degree 2. Indicates current transformersare intended for installation in an environment where only non-conductive POLLUTION occurs, except
21、that occasionally a temporary conductivity caused by condensation is expected.5.8 ENCLOSED-TYPE DEVICE A device that is provided with a complete enclosure and may beinstalled outside of a separate end-product enclosure.JUNE 10, 2016 UL 2808 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
22、CTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONSTRUCTION6 General6.1 In order to reduce the likelihood of creating a risk of electric shock, all metallic parts shall becompletely encased or otherwise recessed within an insulating material and comply with the spacingrequirements within this Outlin
23、e.6.2 Unless otherwise noted, all insulating materials shall be rated with an Electrical Relative ThermalIndex (RTI Elec) of 105C, minimum.6.3 These current transformers shall be evaluated for installation within equipment having a maximumline-to-line voltage of 250 Vac, 600 Vac, 1000 Vac, or 1500 V
24、dc.6.4 These current transformers shall not contain any radio signal generators or other intentional signalemitters.7 Case and Potting Materials7.1 All metallic parts of the current transformer shall be insulated or otherwise recessed within theinsulating case to reduce the likelihood of creating a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT28082016OUTLINEOFINVESTIGATIONFORENERGYMONITORINGCURRENTTRANSFORMERSISSUE3PDF

链接地址:http://www.mydoc123.com/p-1069352.html