《UL SUBJECT 268C-2010 OUTLINE OF INVESTIGATION FOR OUTLINE OF INVESTIGATION FOR MULTI-DETECTOR TEST APPARATUS (Issue Number 1)《SUBJECT 268C 多探测试验设备的调查大纲发布号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 268C-2010 OUTLINE OF INVESTIGATION FOR OUTLINE OF INVESTIGATION FOR MULTI-DETECTOR TEST APPARATUS (Issue Number 1)《SUBJECT 268C 多探测试验设备的调查大纲发布号 1》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJune 29, 20101SUBJECT 268COUTLINE OF INVESTIGATIONFOROUTLINE OF INVESTIGATION FOR MULTI-DETECTOR TEST APPARATUSIssue Number: 1June 29, 2010Summary of TopicsThis first issue of the Subject 268C Ou
2、tline of Investigation for Multi-Detector Test Apparatus covers test equipment that may be used tovalidate the functional operation of multiple integrated sensors ormutually exclusive operating sensors within a single detector.COPYRIGHT 2010 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT
3、AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 29, 2010SUBJECT 268C2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION2 General 52.1 Components .52.2 Units of measurement
4、 .52.3 Reference publications 5CONSTRUCTION3 General 5PERFORMANCE4 General 65 Normal Operation Test 76 Temperature Test .87 Variable Ambient Temperature Tests .117.1 Operation in high and low ambients .117.2 Effect of shipping and storage 128 Humidity Test .129 Circuit Measurement Test .1210 Static
5、Discharge Test .1311 Endurance Test 1312 Abnormal Operation Test 1413 Dielectric Voltage-Withstand Test .1414 Vibration Test 1515 Tests on Polymeric Materials .1515.1 General .1515.2 Temperature test .1516 Electrical Supervision .1617 Dust .1618 Abnormal Application Test .17MARKINGS19 General 17INST
6、RUCTIONS20 Details .18ANNEX A STANDARDS FOR COMPONENTSJUNE 29, 2010 SUBJECT 268C 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTIONScope1.1 These requirements apply to multi detector test apparatus which are intended to supplement t
7、hein-service functional operation of multi-sensor detectors that may include, but not be limited to the integraluse or mutually exclusive use of heat detection, smoke detection, carbon monoxide/gas detectioncapabilities. These apparatus may consist of pressurized gas, liquid, solids or combination t
8、hereof toproduce the necessary simulant.1.2 These products are not intended to assess the performance of the detector in accordance with theapplicable Standard, but are intended to verify functional operation of the detector as defined by thedetector manufacturer.1.3 Multi-detector test apparatus ar
9、e intended for handling and use by a qualified professional.1.4 These products are not intended for use in hazardous locations.1.5 These products have not been assessed for use in oxygen rich environments.1.6 Hazards and/or applications of the materials, chemicals, and/or pressurized container used
10、to storethe primary reactive component used to initiate the intended signaling performance, have not beeninvestigated.1.7 These products are battery operated and may consist of a limited energy, Class 2 powersupply/charging circuit.1.8 These products do not cover:a) Products covered by the Outline f
11、or CO Gas Test Kit for Gas and Vapor Detectors andSensors, SU 2075A;b) Products covered by the Certification Requirement Decision for smoke detector aerosolsprays issued for Smoke Detectors For Fire Alarm Systems, UL 268;c) Test and certification requirements for Alarms, Sensors and/or detectors;d)
12、RF transmission of signals between devices;e) Primary or secondary battery charging circuits, operational life or battery performance/safetyrequirements associated with rechargeable batteries;f) Performance and safety requirements associated with non-rechargeable batteries, org) Emergency signaling
13、equipment as addressed in Standards such as, but not limited to, Gasand Vapor Detectors and Sensors, UL 2075; General-Purpose Signaling Devices and Systems,UL 2017; Smoke Detectors For Fire Alarm Systems, UL 268; Control Units and Accessories forFire Alarm Systems, UL 864; the National Fire Alarm Co
14、de, NFPA 72 and Standard for theInstallation of Carbon Monoxide (CO) Detection and Warning Equipment, NFPA 720.JUNE 29, 2010SUBJECT 268C4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 General2.1 Components2.1.1 Except as indicated in 2.1.2,
15、 a component of a product covered by this outline shall comply with therequirements for that standard. See Annex A for a list of standards covering components generally usedin the products covered by this outline.2.1.2 A component is not required to comply with a specific requirement that:a) Involve
16、s a feature or characteristic not required in the application of the component in theproduct covered by this statement orb) Is superseded by a requirement in this standard.2.1.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.1.4 Specific compo
17、nents are incomplete in construction features or restricted in performancecapabilities. Such components are intended for use only under limited conditions, such as certaintemperatures not exceeding specified limits, and shall be used only under those specific conditions.2.2 Units of measurement2.2.1
18、 The metric unit shall be designated as the official unit for purposes of this standard. Where valuesof measurement are specified in both SI and English units, either unit is used. In cases of dispute, themetric unit shall be used.2.3 Reference publications2.3.1 Where reference is made to other publ
19、ications, such reference shall be considered to refer to thelatest edition and all amendments published to that edition up to the time when this Outline was published.CONSTRUCTION3 General3.1 A multi- detector test apparatus shall be provided with at least one of two functional test elementswhich ma
20、y include but may not be limited to the carbon monoxide, smoke, and heat as components toassess the functional operation of a multi-sensor detector. The safety limits and performancespecifications shall not exceed those specified within this Outline.JUNE 29, 2010 SUBJECT 268C 5UL COPYRIGHTED MATERIA
21、L NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPERFORMANCE4 General4.1 Each end product multi-sensor detector intended for use with the multi-detector test apparatus shallbe subject to all of the applicable tests as defined within this outline. The requirements wi
22、thin this outlinevalidate the functional operation of each multi-detector test apparatus and the multi-sensor detectorperformance is assessed in accordance with the defined limits for the applicable performancerequirements within the standards referenced in 4.2. Sensitivity and performance for each
23、sensortechnology is defined within each standard as referenced in 4.2.4.2 The multi-sensor detectors shall be performance tested before and after each performance testreferenced in this outline and shall comply with the applicable performance requirements referenced in theapplicable Standards or pub
24、lished documents;Smoke Detectors For Fire Alarm Systems, UL 268Sensitivity testDustHeat Detectors for Fire Protective Signaling Systems, UL 521Operating temperature testRate of rise testDustGas and Vapor Detectors and Sensors, UL 2075Sensitivity testElectrical supervisionDustOutline for CO Gas Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT268C2010OUTLINEOFINVESTIGATIONFOROUTLINEOFINVESTIGATIONFORMULTIDETECTORTESTAPPARATUSISSUENUMBER1SUBJECT268C

链接地址:http://www.mydoc123.com/p-1069327.html