《UL SUBJECT 2682-2004 OUTLINE OF INVESTIGATION FOR SWITCH-RATED PLUGS AND RECEPTACLES (Issue Number 1)《(草案)开关额定插头和插座调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2682-2004 OUTLINE OF INVESTIGATION FOR SWITCH-RATED PLUGS AND RECEPTACLES (Issue Number 1)《(草案)开关额定插头和插座调查大纲 发布编号 1》.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、April 20, 20041SUBJECT 2682OUTLINE OF INVESTIGATIONFORSWITCH-RATED PLUGS AND RECEPTACLESIssue Number: 1APRIL 20, 2004Summary of TopicsThis first issue of the Subject 2682 Outline of Investigation for Switch-Rated Plugs and Receptacles covers non-interlocking plugs, receptacles,power inlets and conne
2、ctors for use in switching applications.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2004 UNDERWRITERS LA
3、BORATORIES INC.APRIL 20, 2004SUBJECT 26822No Text on This PageCONTENTSINTRODUCTION1 Scope .72 Glossary .83 General 93.1 Components .93.2 Units of Measurement 10CONSTRUCTION4 General .105 Configurations .106 Insulating Material .107 Resistance to Corrosion 128 Enclosures 128.1 General 128.2 Mechanica
4、l Strength .138.3 Nonmetallic enclosures .138.4 Metallic enclosures 138.5 Attachment plugs 138.6 Specific enclosures 139 Current-Carrying Parts 1410 Clearances and Creepage Distances 1411 Accessibility of Live Parts 1512 Grounding (Bonding) and Dead Metal Parts 1713 Grounding (Bonding) Connections 1
5、814 Terminal Parts 1915 Assembly 2015.1 General .2015.2 Mating and Intermateability 2116 Devices Intended to Accommodate a Fuse 2117 Cord or Cable Grip 22PERFORMANCE18 Representative devices 2219 Accelerated Aging 2519.1 Rubber compounds .2519.2 PVC compounds .2520 Comparative Tracking Index .2521 G
6、low Wire .2522 High-Current Arc Resistance to Ignition 2623 Mold Stress Relief 2724 Moisture Absorption Resistance 2825 Humidity .2826 Insulation Resistance 2927 Dielectric Withstand .3028 Conductor Secureness 3129 Cord or Cable Secureness .3230 Impact (Plugs and Connectors) .33APRIL 20, 2004 SUBJEC
7、T 2682 331 Crush .3532 Withdrawal Force .3633 Grounding (Bonding) Path Current 3634 Short Circuit Withstand and Closing .3734.1 General .3734.2 Protective devices 3834.3 Calibration of test circuits 4135 Strength of Insulating Base and Support .4636 Overload .4737 Temperature Rise .4838 Resistance t
8、o Arcing 4839 Horsepower Rated Locked Rotor .4940 Endurance with Load 4941 Electromagnetic (Pilot Contacts) 5042 Polarization Integrity 5143 Resistance to Corrosion .5144 Moisture Resistance 5144.1 Details 5144.2 Marine type (shipboard use) .5244.3 Watertight .5245 Environmental Enclosure Type Desig
9、nators 52RATINGS46 General 52MARKING47 Details .5347.1 Company name, catalog designation, electrical rating .5347.2 Multiple factories .5447.3 Nonconductive mounting means .5447.4 Cautionary marking size .5447.5 AC only devices 5547.6 Enclosure grounded (or bonded) devices 5547.7 Catalog designation
10、 5547.8 Fused devices .5547.9 Locking-type devices .5547.10 Receptacle marking location 5547.11 Wiring information - field wiring terminals .5647.12 Overcurrent protection - motor rated devices .5647.13 Environmental enclosures 5847.14 Moisture-resistant devices 5848 Identification and Marking of Te
11、rminals 5948.1 General .5948.2 Grounded and grounding (or bonding) 5948.3 Other terminals 61APPENDIX AStandards for ComponentsA1APRIL 20, 2004SUBJECT 26824APRIL 20, 2004 SUBJECT 2682 5No Text on This PageThis page intentionally left blank.APRIL 20, 2004SUBJECT 26826INTRODUCTION1 Scope1.1 This standa
12、rd applies to non-interlocking plugs, receptacles, power inlets, and connectors for use inswitching applications, rated up to 800 amperes and up to 600 volts ac or dc, and which may include pilotcontacts. These devices are intended to provide power from branch circuits, or are for direct connectiont
13、o the branch and motor circuit in accordance with the National Electrical Code ANSI/NFPA 70, usingcopper conductors, for use in either indoor or outdoor nonhazardous locations.1.2 This standard does not apply to:a) Single conductor pin and sleeve devices.b) Devices molded integrally with flexible co
14、rd or cable that are covered by the Standard forCord Sets and Power Supply Cords, UL 817.c) General and special use devices, such as attachment plugs, receptacles, cord connectors,inlets, current taps, flatiron and appliance plugs, that are covered by the Standard forAttachment Plugs and Receptacles
15、, UL 498.d) Single and multi-pole connectors intended for connection to copper conductors, for use indata, signal, control and power applications within and between electrical equipment, whereexposed, that are covered by the Standard for Component Connectors for Use in Data, Signal,Control and Power
16、 Applications, UL 1977.e) Products such as branch circuit switches that are covered by the Standard for Enclosed andDead-Front Switches, UL 98.f) Products such as pin and sleeve devices that are not intended for switching applications andare otherwise covered by the Standard for Plugs, Receptacles,
17、and Cable Connectors, of thePin and Sleeve Type, UL 1682.g) Devices intended for use in hazardous (Classified) locations that are covered by theStandard for Receptacle-Plug Combinations For Use in Hazardous (Classified) Locations, UL1010.APRIL 20, 2004 SUBJECT 2682 72 Glossary2.1 For the purposes of
18、 this standard, the following definitions apply:2.2 CONNECTOR (CABLE CONNECTOR) A portable receptacle that is intended to provide power,with means for attachment of flexible cord or cable and not intended for permanent mounting.2.3 CONTACT A conductive element in a component that mates with a corres
19、ponding element toprovide an electrical path.2.4 CONTACT, PILOT A conductive element intended to carry an indicating or controlling signal.2.5 DEAD FRONT A mechanism or design that prevents unintentional exposure or accessibility tolive contacts on the line side of the connector.2.6 DELAYED ACTION A
20、n arrangement that delays the separation of device housings, which isintended to reduce the likelihood of exposure of arcing contacts during the breaking of the circuit whenthe plug is withdrawn.2.7 ENCLOSURE The case or housing into which the insulator and contacts are assembled. Theenclosure syste
21、m may be composed of elements such as outlet boxes, mounting panels, receptacles,plugs, and connectors.2.8 GROUNDING (BONDING) PATH A path between the grounding contact and the groundingterminal or, if the device has no grounding terminal, the point at which the path makes contact with apart of the
22、metal raceway system, such as a box, box cover, or the raceway itself.2.9 GROUNDING TYPE DEVICE A device having a grounding (bonding) path.2.10 INSULATION, ELECTRICAL The insulation necessary for the proper functioning of the productand for basic protection against electrical shock.2.11 INSULATOR Th
23、at portion of a device that provides for separation and support of contacts.2.12 LOCKING RETAINING MEANS A mechanical arrangement that holds a plug or connector inposition when it is in proper engagement and is intended to reduce the likelihood of its unintentionalwithdrawal. It may also facilitate
24、environmental sealing.2.13 MOTOR RATING A rating expressed in horsepower (hp) and/or full load and locked rotorcurrent, and voltage assigned to a device that is intended to control a motor load.2.14 PLUG (ATTACHMENT PLUG) A device intended to receive power when inserted in a receptacleor connector,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT26822004OUTLINEOFINVESTIGATIONFORSWITCHRATEDPLUGSANDRECEPTACLESISSUENUMBER1 草案 开关 额定 插头 插座 调查

链接地址:http://www.mydoc123.com/p-1069325.html