1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSeptember 12, 20081SUBJECT 2585OUTLINE OF INVESTIGATIONFORREBUILT FLAMMABLE LIQUID METERSIssue Number: 1September 12, 2008SUMMARY OF TOPICSThis First Issue of Subject 2585, Outline of Investigati
2、on for RebuiltFlammable Liquid Meters covers rebuilt positive displacement liquidmeters for flammable and combustible liquids of the type and sizecommonly used in the assembly of motor fuel dispensing devices.The UL Foreword is no longer located within the UL Standard. For informationconcerning the
3、use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2008 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 1
4、2, 2008SUBJECT 25852No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 53 Units of Measurement .54 Undated References 55 Glossary .5CONTRUCTION6 General 67 Gaskets and Seals 6PERFORMA
5、NCE8 General 79 Leakage Test .710 Endurance Test 811 Hydrostatic Strength Test .8MANUFACTURING AND PRODUCTION LINE TESTS12 General .9MARKINGS13 General .914 Permanence of Marking .10INSTRUCTIONS15 General 11APPENDIX AStandards for ComponentsA1SEPTEMBER 12, 2008 SUBJECT 2585 3UL COPYRIGHTED MATERIAL
6、NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover rebuilt positive displacement liquid meters for flammable and combustibleliquids of the type and size commonly used in the assembly of motor fuel dispensing devices.1.2 Fl
7、ammable and combustible liquids as used herein means:a) Gasoline;b) Gasoline/ethanol blends at levels designated “gasohol” or less;c) Diesel fuel; andd) Kerosene.1.3 Meters covered by this Outline are for use in accordance with the National Fire ProtectionAssociations Flammable and Combustible Liqui
8、d Code, NFPA 30, and the Code for Motor FuelDispensing Facilities and Repair Garages, NFPA 30A.1.4 These requirements do not cover:a) Flammable and combustible liquid meters other than of the rebuilt type;b) LP-Gas meters;c) Velocity meters, head meters, or area meters; ord) Meters for use in centra
9、lized fuel oil distribution systems.1.5 Determinations of the suitability of registers, counters, or computers used or provided with thesemeters, or the accuracy of measurement resulting from or required in actual application are not within thescope of these requirements.SEPTEMBER 12, 2008SUBJECT 25
10、854UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline shall comply with therequirements for that component. See Appendix A for a list of standards coveri
11、ng components used in theproducts covered by this Outline2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this Outline, orb) Is superseded by a requirement in t
12、his Outline.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as
13、certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to
14、 a code or standard appearing in the requirements of this Outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purposes of this outline, the following definitions apply.5.2 DIESEL FUEL Fuel formulated in accordance with the Standard Specificat
15、ion for Diesel FuelOils, ANSI/ASTM D975.5.3 GASOLINE Fuel formulated in accordance with the Standard Specification for Automotive Spark-Ignition Motor Fuel, ANSI/ASTM D4814.5.4 GASOLINE/ETHANOL BLENDS Blended fuels formulated in accordance with the StandardSpecification for Automotive Spark-Ignition
16、 Motor Fuel, ANSI/ASTM D4814, when blended withdenatured fuel ethanol formulated in accordance with the Standard Specification for Denatured FuelEthanol for Blending with Gasolines for Use as Automotive Spark-Ignition Engine Fuels, ANSI/ASTMD4806.5.5 KEROSINE Fuel formulated in accordance with the S
17、tandard Specification for Kerosine, ANSI/ASTM D3699.SEPTEMBER 12, 2008 SUBJECT 2585 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTRUCTION6 General6.1 Meters shall comply with the requirements in the Standard for Meters for Flammable and
18、 CombustibleLiquids and LP-Gas, UL 25, except for as modified as follows:a) Gaskets and Seals shall comply with Section 7 of this Outline.b) The Performance Section of UL 25 shall be replaced by the Performance Section of thisOutline. Compliance with the tests described in Sections911arerequired to
19、bedemonstrated.c) Manufacturing and production line tests shall comply with Section 12 of this Outline.7 Gaskets and Seals7.1 Gaskets and seals shall be resistant to the action of the fluid to which they will be exposed.7.2 For flat flanges, a plant fiber gasket shall be note more than 0.8 mm (1/32
20、inch) thick. Acork-composition gasket shall be shellacked in place on one side and coated with graphite on the other.Synthetic rubber gaskets shall have a minimum thickness of 1.6 mm (1/16 inch) and a maximum thicknessof 2.4 mm (3/32 inch).7.3 An elastomeric part used in contact with liquid shall ha
21、ve the following properties when tested asspecified in the Standard for Gasket and Seals, UL 157.a) Those properties relating to minimum tensile strength and elongation after oven aging, asspecified in UL 157. The maximum service temperature used to determine the conditioning timeand temperature for
22、 oven aging is determined to be 60C (140F), unless the product isdesignated for use at higher temperature.b) Low temperature rating of minus 29C (minus 20F).c) Volume change and extraction as specified in the requirements for UL 157, for end useapplications of the fuels covered in this Outline.7.4 T
23、he Standard for Gasket and Seals, UL 157, provides for the testing of either finished elastomericparts, or sheet or slab material. Sheet or slab material is to be tested when the elastomeric parts areO-rings having a diameter less than 25.4 mm (1 inch). The material tested is to be the same as that
24、usedin the product, regardless of whether finished elastomeric parts, or sheet or slab material is tested.SEPTEMBER 12, 2008SUBJECT 25856UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPERFORMANCE8 General8.1 A representative sample of each sp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25852008OUTLINEOFINVESTIGATIONFORREBUILTFLAMMABLELIQUIDMETERSISSUE1 改建 易燃 液体 流量计 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069319.html