UL SUBJECT 2058-2005 OUTLINE OF INVESTIGATION FOR HIGH-SECURITY ELECTRONIC LOCKS (Issue 1)《高安全电子锁调查大纲 发布编号 1》.pdf
《UL SUBJECT 2058-2005 OUTLINE OF INVESTIGATION FOR HIGH-SECURITY ELECTRONIC LOCKS (Issue 1)《高安全电子锁调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2058-2005 OUTLINE OF INVESTIGATION FOR HIGH-SECURITY ELECTRONIC LOCKS (Issue 1)《高安全电子锁调查大纲 发布编号 1》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMarch 31, 20051SUBJECT 2058OUTLINE OF INVESTIGATIONFORHIGH-SECURITY ELECTRONIC LOCKSIssue Number: 1MARCH 31, 2005Summary of TopicsThis is the First Issue of the outline of investigation for High-
2、SecurityElectronic Locks, Subject 2058.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2005 UNDERWRITERS LAB
3、ORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARCH 31, 2005SUBJECT 20582No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .
4、52 General 52.1 Units of measurement .52.2 Components .53 Glossary .64 Installation and Operating Instructions .6CONSTRUCTION5 General 76 Nonmetallic Parts .77 Assembly 78 Protection Against Corrosion .89 Field Wiring Connections 89.1 Field wiring terminals .89.2 General application .89.3 Qualified
5、application 99.4 Field wiring leads 1010 Internal Wiring 1010.1 General .1010.2 Wiring methods 1111 Electrical Components .1111.1 Mounting of components 1111.2 Insulating materials .1211.3 Current-carrying parts .1311.4 Overcurrent protection 1311.5 Semiconductors 1311.6 Primary batteries .1311.7 Sw
6、itches 1411.8 Transformers and coils 1412 Spacings 14PERFORMANCE13 General 1513.1 Test units and data .1513.2 Test voltages 1514 Normal Operation Test 1515 Operation Test .1516 Resistance to Unauthorized Opening 1617 Compromise and Interference Tests 1717.1 General .1717.2 Short circuit test 1717.3
7、Alien direct current (DC) voltage, 0 100 volts 1817.4 Alien direct current (DC) voltage, 100 1000 volts .1817.5 Direct current (DC) noise spikes .1817.6 Electrostatic discharge (ESD) 1817.7 Low voltage, low frequency alternating current (AC) tests .19MARCH 31, 2005 SUBJECT 2058 3UL COPYRIGHTED MATER
8、IAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL17.8 High voltage, low frequency alternating current (AC) tests .1917.9 High power, high frequency alternating current (AC) test 1917.10 Mechanical attack .1918 Input Measurement Test .2019 Standby Power .2020 Under
9、voltage Operation Test .2021 Overvoltage Operation Test 2122 Variable Ambient Test .2123 Humidity Test 2124 Overload Test 2125 Endurance Test 2126 Jarring Test 2227 Temperature Test .2328 Capacitor Reliability Test 2729 Battery Replacement Test .2730 Strain Relief Test .2731 Strength Tests for Enclo
10、sures 2732 Special Terminal Assemblies Tests .2832.1 General .2832.2 Disconnection and reconnection .2832.3 Flexing test 2832.4 Millivolt drop test .2932.5 Temperature test .2933 Vibration Test 29OUTDOOR USE34 General 3035 Rain Test 3036 Dust Test 33MARKING37 General 33ACCESSORY EQUIPMENT38 General
11、3539 Construction .3540 Performance (Installation) Test .3641 Markings .36Appendix AStandards for ComponentsA1MARCH 31, 2005SUBJECT 20584UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover high secur
12、ity electronic locks designed for attachment on doors of safes,chests, vaults, and the like, to provide a means of locking the boltwork against unauthorized opening.1.2 These requirements are intended to test the ability of high-security electronic locks to resistunauthorized opening for a limited p
13、eriod of time. Electronic locks covered by these requirements may ormay not have integral protection against entry by force.1.3 These requirements cover high-security electronic locks powered by low-voltage primary batteries, orfrom Class 2 AC or DC power sources with secondary or primary standby ba
14、tteries, or they generate theirown power as a function of their operation. If the power supply for a high security electronic lock isconnected to a source of high voltage, the high voltage requirements of the Standard for Power Suppliesfor Use with Burglar Alarm Systems, UL 603, shall apply.2 Genera
15、l2.1 Units of measurement2.1.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.2.2 Components2.2.1 Except as indicated in 2.2.2, a component of a product covered by this outline of investigation shallcomply with the requirements
16、for that component. See Appendix A for a list of standards coveringcomponents used in the products covered by this outline of investigation.2.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the comp
17、onent in theproduct covered by this standard, orb) Is superseded by a requirement in this standard.2.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.2.4 Specific components are incomplete in construction features or restricted in performanc
18、ecapabilities. Such components are intended for use only under limited conditions, such as certaintemperatures not exceeding specified limits, and shall be used only under those specific conditions.MARCH 31, 2005 SUBJECT 2058 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIB
19、UTION WITHOUT PERMISSION FROM UL3 Glossary3.1 For the purpose of this outline of investigation, the following definitions apply.3.2 ELECTRICAL CIRCUITS:a) High-Voltage Circuit A circuit involving a potential of not more than 600 volts and havingcharacteristics in excess of those of a low-voltage or
20、an isolated limited secondary circuit.b) Low-Voltage Circuit A circuit involving a potential of not more than 30 volts alternatingcurrent (42.4 volts peak or direct current) and supplied by a primary battery or by a standardClass 2 transformer, or by a combination of transformer and fixed impedance
21、which, as a unit,complies with all the performance requirements for a Class 2 transformer.3.3 PRIMARY BATTERY Any battery which, by construction, is not intended to be recharged.3.4 SECONDARY BATTERY Any battery which, by construction, is intended to be recharged.3.5 STANDBY CONDITION The ready-to-o
22、perate condition which exists prior to being operated tounlock.4 Installation and Operating Instructions4.1 A copy of the installation and operating instructions, related schematic wiring diagrams andinstallation drawings intended to accompany the product are to be furnished with the sample submitte
23、dfor investigation. These items are to be used as a guide in the examination and test of the product, andfor this purpose need not be in final printed form.4.2 The instructions and drawings shall include at least the following:a) Typical installation instructions and drawings and complete representa
24、tive installation wiringdiagram(s) for the product(s) indicating recommended wiring methods.b) A concise description of the operation, testing, and maintenance procedures for theproduct(s), and recommended testing frequency.c) Replacement parts, such as lamps or batteries, identified in the instruct
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT20582005OUTLINEOFINVESTIGATIONFORHIGHSECURITYELECTRONICLOCKSISSUE1 安全 电子锁 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069225.html