UL SUBJECT 1263-2001 Outline of Investigation for Irrigation Cables (Issue 5)《灌溉电缆的调查大纲 发布编号 5》.pdf
《UL SUBJECT 1263-2001 Outline of Investigation for Irrigation Cables (Issue 5)《灌溉电缆的调查大纲 发布编号 5》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1263-2001 Outline of Investigation for Irrigation Cables (Issue 5)《灌溉电缆的调查大纲 发布编号 5》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、February 2,2001 1 SUBJECT 1263 OUTLINE OF INVESTIGATION FOR I R R IG AT1 O N CAB LES Issue Number 5 FEBRUARY 2,2001 COPYRIGHT O 1989, 2001 UNDERWRITERS LABORATORIES INC. 2 SUBJECT 1263 FEBRUARY 2,2001 No Text on This Page FEBRUARY 2. 2001 SUBJECT 1263 3 CONTENTS FOREWORD 4 INTRODUCTION 1 Scope . 5 2
2、 Construction 5 2.1 Conductor . 5 2.2 Insulation 5 2.3 Conductor assembly 5 2.4 Inner jacket 6 2.5 Shields 6 2.6 Shield drain wire . 6 2.7 Outer jacket . 7 2.8 Fittings 7 3 Markings . 8 3.1 Cable markings 8 3.2 Tag marking . 8 3.3 Date of manufacture 9 4 Circuit Identification . 9 4.1 Grounded condu
3、ctor 9 4.2 Grounding conductor 10 4.3 Unidentified conductors 10 5 Test Program 10 5.1 Tests 10 4 SUBJECT 1263 FEBRUARY 2,2001 FOREWORD A. This Outline of Investigation contains basic requirements for products covered by Underwriters Laboratories Inc. (UL) under its Follow-Up Service for this catego
4、ry within the limitations given below and in the Scope section of this Outline of Investigation. They are subject to revision as further experience and investigation may show is necessary or desirable. B. The observance of these requirements by a manufacturer is one of the conditions of the continue
5、d coverage of the manufacturers product. C. A product which complies with the text of this Outline of Investigation will not necessarily be judged to comply with the Outline of Investigation if, when examined and tested, it is found to have other features which impair the level of safety contemplate
6、d by these requirements. D. A product employing materials or having forms of construction which conflict with specific requirements of the Outline of Investigation cannot be judged to comply with the Outline of Investigation. A product employing materials or having forms of construction not addresse
7、d by this Outline of Investigation may be examined and tested according to the intent of the requirements and, if found to meet the intent of this Outline of Investigation, may be judged to comply with the Outline of Investigation. E. UL, in performing its functions in accordance with its objectives
8、, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. The opinions and findings of UL represent its professional judgement given with due consideration to the necessary limitations of practical operation and state of the art at the time the Outline of
9、 Investigation is processed. UL shall not be responsible to anyone for the use of or reliance upon this Outline of Investigation by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or
10、 reliance upon this Outline of Investigation. F. Many tests required by the Outline of Investigations of UL are inherently hazardous and adequate safeguards for personnel and property shall be employed in conducting such tests. FEBRUARY 2,2001 SUBJECT 1263 5 INTRODUCTION 1 Scope 1.1 These cables are
11、 rated 600V, 75C and are for use in wet locations. The insulated-conductor sizes are Nos. 18 - 4/0 AWG stranded copper. The cables are intended to be used in irrigation machines that are electrically driven or electrically controlled in accordance with Article 675 of the National Electrical Code. 2
12、Construction 2.1 Conductor 2.1.1 Annealed stranded copper, bare or coated, in size Nos. 18 - 4/0 AWG. 2.2 Insulation 2.2.1 Listed insulated conductors shall be Types THW-2, THWN-2, XHHW-2, RHW-2, THHW, THW, THWN, RHW, XHHW; or Types TFN, TFFN, RFH-2, or FFH-2 using a wet-locations insulating compoun
13、d rated for at least 75C (167F) (QMlT2 in the case of PVC). 2.2.2 Insulated conductors other than those described in 2.2.1 shall have materials in thicknesses and with temperature ratings appropriate for the specific construction of the irrigation cable in which they are to be used. The materials sh
14、all be evaluated for the requested temperature rating as described in Long-Term Aging, Section 481 of the UL 1581 Reference Standard for Electric Wires, Cables, and Flexible Cords. Investigation of the electrical, mechanical, and physical characteristics of these insulated conductors shall show thes
15、e conductors to be comparable to the conductors described in 2.2.1. The investigation shall include tests such as crushing, impact, abrasion, deformation, heat shock, insulation resistance, and dielectric voltage-withstand. 2.3 Conductor assembly 2.3.1 Conductors of different sizes may be used in th
16、e same cable. The insulated conductors shall be cabled. The length of lay is not specified. The cables shall be provided with fillers where needed to make the finished cable round. 2.3.2 The assembly may be enclosed in a nonmetallic braid, tape, or wrap. 6 SUBJECT 1263 FEBRUARY 2,2001 inches Not ove
17、r 0.700 Over 0.700 but not over 1.500 Over 1.500 but not over 2.500 Over 2.500 2.4 Inner jacket 2.4.1 An inner jacket employing a flame-retardant thermoplastic or thermosetting compound and of a thickness specified in Table 2.1, shall be provided. mm Not over 17.8 Over 17.8 but not over 38.1 Over 38
18、.1 but not over 63.5 Over 63.5 Table 2.1 Minimum thicknesses of inner jacket 36 48 64 Calculated diameter of assembly under inner Minimum average thickness of iacket I iacket 0.91 1.22 1.63 + mils 80 I 2.03 Minimum thickness at any Doint + mils 2.5 Shields 2.5.1 A helically wound or longitudinally a
19、pplied copper or aluminum tape or tapes having a total minimum thickness of 0.008 inch or 0.20 mm and an overlap of not less than 10 percent, or a close-fitting copper or aluminum wire braid shall be applied over the inner jacket. If an aluminum drain wire is used with a shield consisting of a coppe
20、r braid or tape(s), each wire of the copper braid and each copper tape shall have an acceptable continuous coating of tin or another acceptable metal or alloy. 2.6 Shield drain wire 2.6.1 A wire is not required but may be provided as a means of facilitating the termination of the shield. Any drain w
21、ire shall comply with each of the following: a) Shall be applied helically or longitudinally. b) Shall extend throughout the entire length of the cable. c) Shall be of copper or aluminum, with an acceptable continuous coating of tin or another acceptable metal or alloy on a solid copper drain wire (
22、and on each strand of a stranded copper drain wire) that is in contact with a shield consisting of an aluminum braid or tape). d) If of copper, shall not be more than two AWG numbers smaller in size than the smallest circuit conductor in the cable. If of aluminum, shall be at least equal in size to
23、the smallest circuit conductor in the cable. e) Shall be bare (no insulation or other nonmetallic covering) and in intimate contact (good electrical connection) with the shield. FEBRUARY 2,2001 SUBJECT 1263 7 2.6.2 A drain wire smaller than No. 8 AWG may be solid or stranded and, if stranded, may be
24、 in one section or in several sections or individual strands distributed helically or longitudinally around the circumference of the cable. A No. 8 AWG or larger drain wire shall be stranded and in several sections or individual strands distributed helically or longitudinally around the circumferenc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT12632001OUTLINEOFINVESTIGATIONFORIRRIGATIONCABLESISSUE5 灌溉 电缆 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069145.html