1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 23, 20171UL 1204Outline of Investigation for Parts CleanersIssue Number: 3October 23, 2017Summary of TopicsThis new issue of the Outline of Investigation for Parts Cleaners, UL 1204,is be
2、ing issued to add waterbase cleaning solutions and pneumatic partcleaners.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and
3、 rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2017 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 23, 2017UL 12042No Text on This PageUL COPYRIGHTED MATERIAL NOT
4、 AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 General 52.1 Components .52.2 Units of measurement .62.3 Undated references .63 Glossary .6CONSTRUCTION4 General 85 Solvents .86 Pumps .86.1 General .86.2 Water based solution pumps .86.3 El
5、ectric and pneumatic flammable and combustible liquid solvent pumps 97 Supply Connections .97.1 General .97.2 Cord connected products 97.3 Permanently connected products 118 Grounding 138.1 General 138.2 Grounding identification 148.3 Grounding circuit resistance 159 Spacings 159.1 Line voltage circ
6、uits 159.2 Low voltage circuits 16PROTECTION AGAINST INJURY TO PERSONS10 Strength of Materials 1611 Sharp Edges .1612 Stability 1713 Strength of Handles .17PERFORMANCE14 General 1715 Input Test 1816 Starting Current Test 1817 Leakage Current Test .1818 Temperature Test .2219 Ground Circuit Resistanc
7、e Test .2720 Dielectric Test 2721 Cable Arcing Test 2722 Strain Relief Test .2823 Stalled Armature Switch Test .2824 Stability Test .2925 Lid Closure Test 29OCTOBER 23, 2017 UL 1204 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL26 Fluid Lea
8、kage Test .2927 Fusible Link Operation Test 3028 Link Calibration Test 3029 Lid Impact Test .3030 Strength of Handles Test 31MANUFACTURING AND PRODUCTION TESTS31 Dielectric Voltage Withstand Test .3132 Grounding Continuity Test .3233 Fluid Leakage Test .33MARKING34 Markings .3335 Instruction Manual
9、35APPENDIX AStandards for ComponentsA1OCTOBER 23, 2017UL 12044UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover parts cleaners used for cleaning or removing grease and similarsubstances from the it
10、em contaminanted.1.2 These requirements cover electrically operated parts cleaners rated up to 600 V, or manual type partscleaners with no electrical connection.1.3 These units are intended for use with flammable/combustible liquids or non-flammable/non-combustible cleaning solutions as detailed in
11、the instruction manual provided with the unit and labels onthe unit.1.4 Requirements for the installation and use of parts cleaners are included in the National ElectricalCode, NFPA 70, the Flammable and Combustible Liquids Code, NFPA 30, the Uniform Fire Code, NFPA1, and the International Fire Code
12、, IFC.1.5 These requirements do not apply to units intended to be installed outdoors, intended for use withsolvents or cleaning solutions that are considered unstable, or the physiological effects of using theequipment with solvents, cleaning solutions or hazardous waste.2 General2.1 Components2.1.1
13、 Except as indicated in 2.1.2, a component of a product covered by this outline shall comply with therequirements for that component. See Appendix A for a list of standards covering components used in theproducts covered by this outline.2.1.2 A component is not required to comply with a specific req
14、uirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.2.1.3 A component shall be used in accordance with its rating established for the intended conditions ofus
15、e.2.1.4 Specific components are incomplete in construction features or restricted in performancecapabilities. Such components are intended for use only under limited conditions, such as certaintemperatures not exceeding specified limits, and shall be used only under those specific conditions.OCTOBER
16、 23, 2017 UL 1204 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.2 Units of measurement2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.2.3 Undated references2.3.1
17、 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.3 Glossary3.1 For the purposes of this outline, the following definitions apply.3.2 AUTO-IGNITION TEMPERATURE The minimum tempera
18、ture at which fuel-air mixtures will ignitespontaneously. This temperature is to be determined either at atmospheric pressure (14.7 psig), or at themaximum pressure present in the area of the fuel-air mixture, whichever is higher. At atmosphericpressure, the auto-ignition temperature of a solvent sh
19、all be determined in accordance with the StandardTest Method for Auto-Ignition Temperature of Liquid Chemicals, ASTM E 659.3.3 COMBUSTIBLE LIQUID A material that has a fluidity greater than 300 penetration asphalt whentested in accordance with the Standard Test Method for Penetration for Bituminous
20、Materials, ASTM D 5,and that has a closed cup flash point at or above 37.8C (100F). Combustible liquids are subdivided asfollows:a) Class II liquids include those having flash points at or above 37.8C and below 60C(140F);b) Class IIIA liquids include those having flash points at or above 60C and bel
21、ow 93C(200F); andc) Class IIIB liquids include those having flash points at or above 93C.3.4 FLAMMABLE LIQUID A material that has a fluidity greater than 300 penetration asphalt whentested in accordance with the Standard Test Method for Penetration for Bituminous Materials, ASTM D 5,and that has a c
22、losed cup flash point below 37.8C (100F) and a vapor pressure not exceeding 2068 mmHg (40 psia). Flammable liquids are Class I liquids, and are subdivided as follows:a) Class IA liquids include those having flash points below 22.8C (73F) and having a boilingpoint below 37.8C (100F);b) Class IB liqui
23、ds include those having flash points below 22.8C (73F) and having a boilingpoint at or above 37.8C (100F); andc) Class IC liquids include those having flash points at or above 22.8C (73F) and below37.8C (100F).OCTOBER 23, 2017UL 12046UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
24、DISTRIBUTION WITHOUT PERMISSION FROM UL3.5 FLASH POINT The minimum temperature at which a liquid gives off vapor in sufficient concentrationto form an ignitable mixture with air near the surface of the liquid within the vessel as specified by theappropriate test procedure and apparatus as follows:a)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT12042017OUTLINEOFINVESTIGATIONFORPARTSCLEANERSISSUE3PDF

链接地址:http://www.mydoc123.com/p-1069137.html