UL 962A CRD-2017 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 13 7 and 50 24 Subject FPDU Employing Tamper Resistant Outlets (Edition 4 .pdf
《UL 962A CRD-2017 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 13 7 and 50 24 Subject FPDU Employing Tamper Resistant Outlets (Edition 4 .pdf》由会员分享,可在线阅读,更多相关《UL 962A CRD-2017 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 13 7 and 50 24 Subject FPDU Employing Tamper Resistant Outlets (Edition 4 .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): IYNCStandard Number: UL 962AStandard Title: Standard for Furniture Power Distribution UnitsEdition Date: February 22, 2016Edition Number: 4Section / Paragraph Reference: Paragraphs 5.3.1, 5.5, 13.7.1
3、through 13.7.4, Tables12.1 and 26.1Subject: Furniture Power Distribution unit with a current tap fittingDECISION:In addition to the applicable requirements contained in UL 962A, a power supply cord of a furniture powerdistribution which employs a current tap fitting shall also comply with the follow
4、ing:5 Glossary5.3.1 CURRENT TAP An attachment plug with a single integral outlet device.5.5 FURNITURE POWER DISTRIBUTION UNIT (FPDU) An electrical enclosure provided with anattached power supply cord and attachment plug or current tap for connection to a permanently installedbranch circuit receptacl
5、e outlet. The FPDU is provided with a mounting means for attachment to afurnishing. The electrical enclosure may be provided with one or more receptacle outlets. The FPDU mayalso be provided in any combination of the following configurations:a) The electrical enclosure connected to the power supply
6、cord and attachment plug may besupplied with up to six lengths of flexible cord not exceeding 6 feet in length; each length shallbe terminated with a maximum of 3 receptacle outlets within an electrical enclosure or 3 cordconnectors. Refer to Clause 13.6 limiting the total number of outlets, Table 1
7、2.1 for overloadrequirements and 12.1.8 for interconnecting cord requirements.b) Provided with supplementary overcurrent protection.c) Provided with manual or automatic switch(es) such as an integral appliance timer to controlall or some of the receptacle outlets.d) Provided with indicator lights.e)
8、 When provided with three or more receptacle outlets the FPDU may be provided with asurge protective device (SPD) or an electromagnetic interference (EMI) filter.f) A FPDU may employ non-electrical decorative features. The decorative features may includevarious shapes such as rocks, birds and animal
9、s, etc.g) A FPDU may employ telephone equipment and communication circuit protectors.h) A FPDU may employ an antenna discharge unit or provide antenna connections fortelevisions and video products.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM
10、ULi) When provided with three or more receptacle outlets the FPDU may be provided with LED(Light Emitting Diode) Luminaire(s).j) A FPDU may be provided with a wireless charging circuit.k) Provided with isolated secondary circuits.l) Provided with batteries located in isolated secondary circuits. See
11、 UL 962A Supplement SA -Furniture Power Distribution Units Incorporating Batteries.m) Provided with an integral Class 2 lead and mating Class 2 separable interface, or anintegral power supply with one or more Class 2 output connector(s).n) Provided with receptacles with integral power supplies with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL962ACRD2017ULSTANDARDFORSAFETYFURNITUREPOWERDISTRIBUTIONUNITSSECTIONPARAGRAPHREFERENCE137AND5024SUBJECTFPDUEMPLOYINGTAMPERRESISTANTOUTLETSEDITION4PDF

链接地址:http://www.mydoc123.com/p-1069083.html