UL 891-2005 UL Standard for Safety Switchboards (Eleventh Edition Reprint with revisions through and including October 31 2012)《配电盘》.pdf
《UL 891-2005 UL Standard for Safety Switchboards (Eleventh Edition Reprint with revisions through and including October 31 2012)《配电盘》.pdf》由会员分享,可在线阅读,更多相关《UL 891-2005 UL Standard for Safety Switchboards (Eleventh Edition Reprint with revisions through and including October 31 2012)《配电盘》.pdf(226页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 891 SwitchboardsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR D
2、ISTRIBUTION WITHOUT PERMISSION FROM UL Switchboards, UL 891 Eleventh Edition, Dated July 26, 2005 Summary of Topics These revisions for ANSI/UL 891 are being issued to incorporate the following changes in requirements: Revision based on panelboard changes in the 2008 NEC Update wire bending space fo
3、r compact stranded AA-8000 aluminum to match UL 67 and the National Electrical Code NFPA 70 Clarify intent of front and rear accessible denitions Update wire bending requirements to match the exception in UL 1558 for LV Switchgear Add required Latch Pull Test 9.2.9 to Table 12 Enclosure Type test re
4、quirements 80% marking requirement location category identication Clarify requirements for the service equipment intended for use with multiple sources Revision to switch handle requirements to limit requirement to those switches which operate vertically between the on and off position Mounting orie
5、ntation of circuit breakers or switches Accessibility requirements for de-energizing branch circuits Inclusion of allowance for alternate gap spacing at anged cover constructions Inclusion of meter socket maximum peak let-through current criteria to pass/fail criteria Bracing of load conductors duri
6、ng short-circuit tests Reinsert requirements necessary in determining the short-circuit current rating of a switchboard Requirements for the identication of grounding and bonding conductors Requirements for the securement of meter socket covers Reinsert requirement for marking on switchboard interio
7、rs. Update requirements for installation of surge-protective devices at services Clarify requirements in maximum temperature rise table Multiple corrections Clarify ground-fault protection requirements to address use of rating plugs OCTOBER 31, 2012 UL 891 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED F
8、OR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Correction to 600 volt thermoplastic appliance wiring material insulation, Table 29 Correction to rating and sizes of single bus bars 800 amperes maximum, Table 25 Addition of lighting xtures to Table 16 Correct system references for
9、 audio or visual only ground fault protection Grounding transformers for high impedance grounded systems Equipment door opening 90 degrees from the closed position Use of weather-resistant type receptacles Text that has been changed in any manner or impacted by ULs electronic publishing system is ma
10、rked with a vertical line in the margin. The new/revised requirements are substantially in accordance with Proposal(s) on this subject dated July 9, 2010 and March 30, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form b
11、y any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no
12、 event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised
13、of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss
14、, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraph
15、s, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS noti
16、ce. The following table lists the future effective dates with the corresponding reference. OCTOBER 31, 2012 UL 891 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Future Effective Date Reference October 31, 2014 Clauses 8.1.5.5, 8.6.11.22
17、, and 8.6.14.9. OCTOBER 31, 2012 UL 891 tr3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 31, 2012 UL 891 tr4 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FRO
18、M UL Association of Standardization and Certication NMX-J-118/2-ANCE-2012 Third Edition CSA Group CSA C22.2 No. 244-05 First Edition Underwriters Laboratories Inc. UL 891 Eleventh Edition Switchboards July 26, 2005 (Title Page Reprinted: October 31, 2012) ANSI/UL 891-2012UL COPYRIGHTED MATERIAL NOT
19、AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operating as CSA Group), and Underwriters Laboratories Inc. (UL).
20、 Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions t
21、o this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages. Copyright 2012 ANCE Rights reserved in favor of ANCE. ISBN 1
22、-55436-859-6 2005 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. CSA Group Standards are subject to periodic review, and suggestions for their improvement will be referred to the appropriate committee
23、. To submit a proposal for change, please send the following information to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase C
24、SA Group Standards and related publications, visit CSAs Group Online Store at www.shopcsa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2012 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL8912005ULSTANDARDFORSAFETYSWITCHBOARDSELEVENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGOCTOBER312012

链接地址:http://www.mydoc123.com/p-1069038.html