UL 668 CRD-2015 UL Standard for Safety Hose Valves for Fire-Protection Service - Section Paragraph Reference 11 and 12 Subject Inlets and Outlets (Edition 10 April 28 2004).pdf
《UL 668 CRD-2015 UL Standard for Safety Hose Valves for Fire-Protection Service - Section Paragraph Reference 11 and 12 Subject Inlets and Outlets (Edition 10 April 28 2004).pdf》由会员分享,可在线阅读,更多相关《UL 668 CRD-2015 UL Standard for Safety Hose Valves for Fire-Protection Service - Section Paragraph Reference 11 and 12 Subject Inlets and Outlets (Edition 10 April 28 2004).pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): VTSRStandard Number: UL 668Standard Title: Standard for Hose Valves for Fire-Protection ServiceEdition Date: April 28, 2004Edition Number: 10Section / Paragr
3、aph Reference: 11 and 12Subject: Inlets and OutletsDECISION:Valves may use grooved inlets in accordance with AWWA C600 or alternative threads on inlets andoutlets provided that the threads comply with a nationally recognized standard.11 Inlets Threads and Attachment Means11.1 A hose valve intended f
4、or use on a fire pump and a standpipe shall be fitted at the inlet end with oneof the following:a) fFemale pipe threads complying with ANSI/ASME B1.20.1, Pipe Threads, General Purpose(Inch)b) Grooved ends complying with the Standard for Grooved and Shouldered Joints, ANSI/AWWAC600c) Pipe threads com
5、plying with a national standard that applies where the valve is intended tobe installed.11.2 A hydrant hose valve shall be constructed to attach to hydrant barrels by use of two 3/4 inch (19.1mm) tap bolts, spaced horizontally 5-5/8 inches (143 mm) on centers. A hydrant hose valve shall bepermitted
6、to attach to hydrant barrels using a flange complying with a national standard that applies wherethe valve is to be installed.12 Outlet Nipples and Threads12.1 A hose valve outlet shall be threaded in accordance with the Standard for Fire Hose Connections,NFPA 1963, unless otherwise specifically ord
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL668CRD2015ULSTANDARDFORSAFETYHOSEVALVESFORFIREPROTECTIONSERVICESECTIONPARAGRAPHREFERENCE11AND12SUBJECTINLETSANDOUTLETSEDITION10APRIL282004PDF

链接地址:http://www.mydoc123.com/p-1068802.html