UL 61058-1 (ND)-2009 National Differences For UL 61058-1 Switches for Appliances - Part 1 General Requirements (Fourth Edition Reprint with revisions through and including February.pdf
《UL 61058-1 (ND)-2009 National Differences For UL 61058-1 Switches for Appliances - Part 1 General Requirements (Fourth Edition Reprint with revisions through and including February.pdf》由会员分享,可在线阅读,更多相关《UL 61058-1 (ND)-2009 National Differences For UL 61058-1 Switches for Appliances - Part 1 General Requirements (Fourth Edition Reprint with revisions through and including February.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 61058-1Switches for Appliances - Part 1: General RequirementsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNa
2、tional Differences ForUL 61058-1Switches for Appliances - Part 1: General RequirementsEdition: 4Edition Date: August 10, 2009UL 61058-1 is an adoption of the second amendment of IEC 61058-1 published in November2007, the consolidated reprint of IEC 61058-1 Ed. 3.2 published in April of 2008, and the
3、Corrigendum to IEC 61058-1 Ed 3.0 published in January of 2009.The revisions dated February 15, 2013 were issued to reflect the latest ANSI approval date as anAmerican National Standard and to include the following revisions that were proposed June 8,2012. Please note that the national difference do
4、cument incorporates all of the U.S. nationaldifferences for UL 61058-1 including the new and revised national differences itemized below.1. Added a new national difference, Clause 21.4DV, for the use of thermoset material.2. Clarified the use of RTI values in Clauses 21.1DV.1.1.1 and 21.1DV.1.1.2, a
5、nd addedinstructions on the thickness of material in Clause 21.1DV.1.1.3.3. Revised Clause DVB.4.1 for clarification.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may b
6、e reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited
7、 to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use
8、 this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs
9、 Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers com
10、puter system.Copyright Underwriters Laboratories Inc.FEBRUARY 15, 2013NATIONAL DIFFERENCES FOR UL UL 61058-12UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 15, 2013 NATIONAL DIFFERENCES FOR UL UL 61058-1 3UL COPYRIGHTED MATERIAL NOT
11、AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify
12、 national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of
13、products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and wi
14、ll not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what th
15、e national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to i
16、nclude adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theadditio
17、n, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.FEBRUARY 15, 2013NATIONAL DIFFERENCES FOR UL UL 61058-14UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL
18、National Differences1.1DV.1 D2 Modification of 1.1 to revise Note 6 as follows:Remove relevant Part 2 of IEC 61058 and replace with appropriate supplements,annexes to UL 61058-1, CSA 22.2 No. 61058-1, or UL and CSA Standards.1.1DV.2 D2 Modification of 1.1 to include electrical ratings unique to Nort
19、h America(such as switches with a horsepower (hp), lamp loads, and television (TV) ratings) byadding the following:See Annexes DVA, DVB, and DVC.1.7DV D2 Addition of 1.7DV to indicate which switches do not apply:These requirements do not cover those electronic controls covered by existing standardss
20、uch as UL 244A, UL 60730, CSA C22.2 No. 156, and CSA E60730-1. Examples of theseproducts include automatic controls, unintentional automatic OPERATION, and sensing(temperature, pressure, light, etc.) actuation.1.8DV DC Addition of 1.8DV to indicate which switches do not apply:These requirements do n
21、ot cover switches which are covered by an existing standard suchas those constructed so that they can be installed readily in a flush-device box or anoutlet-box cover or can otherwise be used in a wiring system that complies with NFPA-70and Part 1 of the Canadian Electrical Code (CEC). This part doe
22、s not apply to switchesintended to be covered within the scope of CSA C22.2 No. 111, UL 20, CSA C22.2 No. 4, UL98, CSA C22.2 No. 205, or UL 773A.2DV DC Modification to add the following:ASTM D3638Standard Test Method for Comparative Tracking Index of Electrical Insulation MaterialsCSA C22.2 No. 0.17
23、Evaluation of Properties of Polymeric MaterialsIEC 60695-11-10:2003Fire hazard testing Part 11-10: Test flames 50 W horizontal and vertical flame testmethodsAmendment 1 (2003)UL 94Tests for Flammability of Plastic Materials for Parts in Devices and AppliancesUL 746BPolymeric Materials Long Term Prop
24、erty EvaluationsFEBRUARY 15, 2013 NATIONAL DIFFERENCES FOR UL UL 61058-1 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.1.32DV D2 Addition:COMPARATIVE TRACKING INDEX (CTI): The voltage, as determined under the conditions specifiedin the St
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL610581ND2009NATIONALDIFFERENCESFORUL610581SWITCHESFORAPPLIANCESPART1GENERALREQUIREMENTSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGFEBRUARYPDF

链接地址:http://www.mydoc123.com/p-1068669.html