UL 60730-2-9-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-9 Particular Requirements for Temperature Sensing Controls (Fourth Edition).pdf
《UL 60730-2-9-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-9 Particular Requirements for Temperature Sensing Controls (Fourth Edition).pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-9-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-9 Particular Requirements for Temperature Sensing Controls (Fourth Edition).pdf(101页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60730-2-9 Standard for Automatic Electrical Controls Part 2-9: Particular Requirements for Temperature Sensing Controls STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
2、REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Standard for Automatic Electrical Controls Part 2-9: Particular Requirements for Temperature Sensing Controls,
3、UL 60730-2-9 Fourth Edition, Dated February 14, 2017 Summary of Topics This new edition of ANSI/UL 60730-2-9 adopts the fourth edition of IEC 60730-2-9 with national differences. The new requirements are substantially in accordance with Proposal(s) on this subject dated December 2, 2016. All rights
4、reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed
5、or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out o
6、f the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electro
7、nic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard
8、 on the purchasers computer system. FEBRUARY 14, 2017 UL 60730-2-9 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 14, 2017 UL 60730-2-9 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR D
9、ISTRIBUTION WITHOUT PERMISSION FROM UL February 14, 2017 1 UL 60730-2-9 Standard for Automatic Electrical Controls Part 2-9: Particular Requirements for Temperature Sensing Controls Prior to the rst edition of UL 60730-2-9, the requirements for the products covered by this Standard were included in
10、UL 8730-2-9. First Edition January, 2003 Third Edition October, 2010 Fourth Edition February 14, 2017 This ANSI/UL Standard for Safety consists of the Fourth Edition. The most recent designation of ANSI/UL 60730-2-9 as an American National Standard (ANSI) occurred on February 14, 2017. ANSI approval
11、 for a standard does not include the Cover Page, Transmittal Pages, Title Page, or Preface. The National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any tim
12、e. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrigh
13、ts, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 60730-2-9-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 14, 2017 UL
14、 60730-2-9 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 8 NATIONAL DIFFERENCES . 9 FOREWORD . 10 1 Scope and normative references .13 1.1 Scope 13 1.2 Normative references 14 2 Terms and denitio
15、ns 15 2.2 Denitions of types of control according to purpose 15 2.3 Denitions relating to the function of controls .18 2.5 Denitions of types of control according to construction 18 3 General requirements 18 4 General notes on tests .18 4.1 Conditions of test 18 4.2 Samples required 19 5 Rating 19 6
16、 Classication 19 6.4 According to features of automatic action .19 6.7 According to ambient temperature limits of the switch head .20 6.15 According to construction .20 7 Information 20 7.2 Methods of providing information 20 8 Protection against electric shock .23 9 Provision for protective earthin
17、g .23 10 Terminals and terminations 23 11 Constructional requirements 23 11.1 Materials 23 11.3 Actuation and operation .23 11.4 Actions 24 11.6 Mounting of controls 27 11.101 Time factor 27 12 Moisture and dust resistance .27 12.101 Refrigeration controls .27 13 Electric strength and insulation res
18、istance .28 14 Heating 29 15 Manufacturing deviation and drift .32 15.5.6CDV.1 Fan/heat sequencer Initial time-calibration test I 33 15.5.6DDV.1 Fan/heat sequencer Initial time-calibration test II 34 15.5.6EDV.1 The following is applicable to controls classied under 6.7.103BDV. 34 16 Environmental s
19、tress 36 17 Endurance .36 17.15 Single operation devices .36 17.16 Test for particular purpose controls 38 17.101 Type 2.P cycling test .43 18 Mechanical strength .45 18.101 Push-and-turn or pull-and-turn actuation 45 18.102 Parts containing liquid metal .46 19 Threaded parts and connections 47 FEBR
20、UARY 14, 2017 UL 60730-2-9 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 20 Creepage distances, clearances and distances through solid insulation .47 21 Resistance to heat, re and tracking 47 22 Resistance to corrosion 47 23 Electromagnet
21、ic compatibility (EMC) requirements Emission .47 23.101.1 Test conditions .47 23.101.2 Test procedure .48 24 Components .48 25 Normal operation .48 26 Electromagnetic compatibility (EMC) requirements Immunity .48 27 Abnormal operation .48 27.101DV.1 Overvoltage .48 27.102DV.1 Thermal Cycling .48 27.
22、103DV.1 Short Circuit 49 28 Guidance on the use of electronic disconnection .51 Annexes Annex G (normative) Heat and re resistance tests G.5.1 Ball pressure test 1 53 G.5.2 Ball pressure test 2 53 Annex H (normative) Requirements for electronic controls H.2 Terms and denitions 54 H.6 Classication 54
23、 H.6.18 According to classes of control functions 54 H.7 Information 54 H.11 Constructional requirements 55 H.11.12 Controls using software 55 H.23 Electromagnetic compatibility (EMC) requirements Emission .55 H.26 Electromagnetic compatibility (EMC) requirements Immunity .55 H.26.5 Voltage dips, vo
24、ltage interruptions and voltage variations in the power supply network .56 H.26.8 Surge immunity test 57 H.26.9 Electrical fast transient/burst immunity test 57 H.26.10 Ring wave immunity test .57 H.26.12 Radio-frequency electromagnetic eld immunity .58 H.26.13 Test of inuence of supply frequency va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL60730292017ULSTANDARDFORSAFETYAUTOMATICELECTRICALCONTROLSCPART29PARTICULARREQUIREMENTSFORTEMPERATURESENSINGCONTROLSFOURTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068514.html