UL 60730-2-4 (ND)-2003 National Differences For UL 60730-2-4 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motic.pdf
《UL 60730-2-4 (ND)-2003 National Differences For UL 60730-2-4 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motic.pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-4 (ND)-2003 National Differences For UL 60730-2-4 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motic.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-4Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Thermal Motor Protectors for Motor-Compressors of
2、Hermetic and Semi-Hermetic TypeUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-4Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Thermal Motor Prote
3、ctors for Motor-Compressors of Hermetic and Semi-HermeticTypeEdition: 1Edition Date: January 17, 2003These revisions are being issued to:1) Add a national difference to the Heat, Fire and Tracking section, Section 21, to clarify that it isapplicable only to non-metallic and insulating materials whic
4、h are outside the motor-compressorhousing.2) Reflect the established effective date of UL 60730-2-4. AS OF OCTOBER 19, 2018, THETWELFTH EDITION OF UL 873 WILL BE WITHDRAWN AND WILL BE REPLACED BY THISSTANDARD.This document provides a single listing of the National Differences included in the UL adop
5、tion ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards docume
6、nt as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost
7、savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this sta
8、ndards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or
9、 deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.MAY 28, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-42UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION
10、 FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in t
11、his document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These a
12、re deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized
13、with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is
14、 used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A
15、 deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an
16、entire clause,subclause, table, figure, or annex of the base IEC text.MAY 28, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-4 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1DV DE Addition of the following Note to 1.1 of
17、the part 2:NOTE Requirements concerning the testing of the combination of hermetic motor-compressor andTHERMAL MOTOR PROTECTOR are given in UL 60335-2-34.1.1.1DV D2 Modification of 1.1.1 of the part 2:This standard applies to THERMAL MOTOR PROTECTORS for motor-compressors within the scopeof UL 60335
18、-2-34.1.2DV DR Modification of 1.2 of the part 2:This standard applies to THERMAL MOTOR PROTECTORS for use with hermetic motor-compressorswith a RATED VOLTAGE equal to or less than 600 V. No specific output power limits apply.1.5DV DE Addition to 1.5 of the part 2:The following UL Standard is quoted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6073024ND2003NATIONALDIFFERENCESFORUL6073024STANDARDFORAUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART2PARTICULARREQUIREMENTSFORTHERMALMOTICPDF

链接地址:http://www.mydoc123.com/p-1068491.html