UL 489 CRD-2018 UL Standard for Safety Molded-Case Circuit Breakers Molded-Case Switches and Circuit-Breaker Enclosures - Section Paragraph Reference 6 17 1 9 18 1 Subject Revisio.pdf
《UL 489 CRD-2018 UL Standard for Safety Molded-Case Circuit Breakers Molded-Case Switches and Circuit-Breaker Enclosures - Section Paragraph Reference 6 17 1 9 18 1 Subject Revisio.pdf》由会员分享,可在线阅读,更多相关《UL 489 CRD-2018 UL Standard for Safety Molded-Case Circuit Breakers Molded-Case Switches and Circuit-Breaker Enclosures - Section Paragraph Reference 6 17 1 9 18 1 Subject Revisio.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): DIMV, DIMV7, DIYA, DIYA7, DKPU2, DKPU8, DIVQ, DIVQ7,DKTY, DIRW, DIRW7, DIYV, DIYV7Standard Number: UL 489Standard Title: Standard for Molded-Case Circuit Breakers, Molded-Case Switches,and Circuit-Bre
3、aker EnclosuresEdition Date: October 24, 2016Edition Number: 13Section / Paragraph Reference: 6.17.1, 9.18.1Subject: Revision to Compliance criteria for Circuit breakers with a neutral pole.DECISION:6.17.1 4-pole constructions shall be permitted to be used for 3-phase circuits where a switched neutr
4、al isrequired. The fourth pole shall be provided with overcurrent protection of any value between 0 through 100percent of the other poles, inclusive either without overcurrent protection or with overcurrent protection of50 or 100 percent of the other poles. See 7.1.1.18, 7.17.1 - 7.17.3, and 9.18.1.
5、9.18.1 A 4-pole circuit breaker shall have the fourth (neutral) pole marked “Protection - _% In”. Thepercentage indicated shall be 0, 50 or 100 any value 0 through 100 inclusive, in increments of 10. LocationCategory B.RATIONALE FOR DECISION:This CRD expands the ability of circuit breakers to have n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL489CRD2018ULSTANDARDFORSAFETYMOLDEDCASECIRCUITBREAKERSMOLDEDCASESWITCHESANDCIRCUITBREAKERENCLOSURESSECTIONPARAGRAPHREFERENCE61719181SUBJECTREVISIOPDF

链接地址:http://www.mydoc123.com/p-1068207.html