UL 4248-1 CRD-2014 UL Standard for Safety Fuseholders - Part 1 General Requirements - Section Paragraph Reference Multiple definitions construction performance Subject Allow for m.pdf
《UL 4248-1 CRD-2014 UL Standard for Safety Fuseholders - Part 1 General Requirements - Section Paragraph Reference Multiple definitions construction performance Subject Allow for m.pdf》由会员分享,可在线阅读,更多相关《UL 4248-1 CRD-2014 UL Standard for Safety Fuseholders - Part 1 General Requirements - Section Paragraph Reference Multiple definitions construction performance Subject Allow for m.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): IZLT, IZMR, IZNDStandard Number: UL 4248-1Standard Title: Standard for Fuseholders - Part 1: General RequirementsEdition Date: February 28, 2007Edition Numbe
3、r: 1Section / Paragraph Reference: Multiple: definitions, construction, performanceSubject: Allow for multilple cables per phase smaller than 1/0 AWGDECISION:Use the following clauses in conjunction with UL 4248-12.1.15 Special Purpose Fuseholder “Not for General Use” a fuseholder having special fea
4、tures limitingtheir suitability to specific applications.6.1.8 Fuseholders having special features limiting their suitability to specific applications shall be markedSpecial Purpose - Not For General Use, or equivalent. Instructions shall be provided by themanufacturer detailing the application(s).
5、See 7.5.10.7.1.3 Special purpose “Not for general use” Special purpose fuseholders shall comply with theconstruction requirements of this standard, except the type or construction of the terminals are such thefuseholder can only be used in specific equipment applications and is not suitable for fiel
6、d installation inaccordance with NEC.(Revised) Table 7.2, Note For terminals that accommodate multiple conductors, see 7.5.9 and 7.5.10.7.5.9 Fuseholders intended for paralleling field wired conductors shall be sized for accommodatingparalleled conductors 1/0 AWG and larger, with the ampacity of the
7、 fuseholder based on multiplying thenumber of conductors by the conductor ampacity.7.5.10 Fuseholders intended for factory wiring only, the ampacity shall be specified by the manufacturerand determined by compliance with performance testing outlined in this Standard. When factory wiredterminals are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL42481CRD2014ULSTANDARDFORSAFETYFUSEHOLDERSPART1GENERALREQUIREMENTSSECTIONPARAGRAPHREFERENCEMULTIPLEDEFINITIONSCONSTRUCTIONPERFORMANCESUBJECTALLOWFORMPDF

链接地址:http://www.mydoc123.com/p-1068129.html