UL 250 CRD-2012 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Supplement SA Subject Flammable Refrigerant Requirements EPA SNAP Differe.pdf
《UL 250 CRD-2012 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Supplement SA Subject Flammable Refrigerant Requirements EPA SNAP Differe.pdf》由会员分享,可在线阅读,更多相关《UL 250 CRD-2012 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Supplement SA Subject Flammable Refrigerant Requirements EPA SNAP Differe.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): SHMR, SHZZStandard Number: UL 250Edition Date: November 1, 1993Edition Number: 10Section / Paragraph Reference: Supplement SASubject: Flammable Refrigerant R
3、equirements, EPA SNAP Differences.Supercedes prior Certification Requirement Decision issued March 1, 2012.DECISION:SA3.3 The charge size for refrigerators or freezers shall be as follows for the kind of refrigerant used. Ifthe refrigerator contains multiple refrigeration circuits, the charge limit
4、is applied to each refrigerationcircuit:a) No charge limit - ASHRAE 34 Class 1 “No-Flame Propagation” refrigerant. Has no limits of flammability,has either an autoignition temperature less than or equal to 750C (1382F) or no autoignitiontemperature.b) No charge limit - When the blend complies with t
5、he exception to SA3.4.c) 225 grams (8.0 oz) - ASHRAE 34 Class 2 “Lower Flammability” refrigerant. Has limits of flammability,and heat of combustion less than 19,000 kj/kg (8,174 Btu/lb). When the leaked amount of refrigerantduring leak scenario testing of the refrigerating system, does not exceed 22
6、5 grams (8.0 oz), a largeramount of charge is not prohibited from being used.d) 57 50 grams (2.01 1.7 oz) - ASHRAE 34 Class 3 “Higher Flammability” refrigerant. Has limits offlammability and heat of combustion greater than 19,000 kj/kg (8,174 Btu/lb). When the leaked amount ofrefrigerant during leak
7、 scenario testing of the refrigerating system does not exceed 50 grams (1.7 oz), alarger amount of charge is not prohibited from being used.SA5.1.2.6 The concentration of leaked refrigerant inside the food storage compartments and inside anyinternal or external electrical component compartment is to
8、 be measured continuously from the beginningof the test and for at least one 24 hours after the injection of the refrigerant vapor has stopped. Theinstrument used for monitoring the refrigerant concentration, such as gas chromatography which usesinfrared sensing techniques, should have a fast speed
9、of response (typically 2 or 3 seconds) and notinfluence the result of the test.SA6.1.1 The following markings, or the equivalent, shall be provided at the locations indicated and shallbe permanent when a flammable refrigerant is used:a) On or near any evaporators that can be contacted by the consume
10、r: “DANGER Risk OfFire or Explosion. Flammable Refrigerant Used. Do Not Use Mechanical Devices To DefrostRefrigerator. Do Not Puncture Refrigerant Tubing”.b) Near the machine compartment: “DANGER Risk Of Fire Or Explosion. FlammableRefrigerant Used. To Be Repaired Only By Trained Service Personnel.
11、Do Not PunctureRefrigerant Tubing”.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULc) Near the machine compartment: “CAUTION Risk Of Fire Or Explosion. FlammableRefrigerant Used. Consult Repair Manual/Owners Guide Before Attempting To Service
12、ThisProduct. All Safety Precautions Must be Followed”.d) On the exterior of the refrigerator: “CAUTION Risk Of Fire Or Explosion. Dispose OfProperlty In Accordance With Federal Or Local Regulations. Flammable Refrigerant Used”.e) Near any and all exposed refrigerant tubing: “CAUTION Risk Of Fire Or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL250CRD2012ULSTANDARDFORSAFETYHOUSEHOLDREFRIGERATORSANDFREEZERSSECTIONPARAGRAPHREFERENCESUPPLEMENTSASUBJECTFLAMMABLEREFRIGERANTREQUIREMENTSEPASNAPDIFFEREPDF

链接地址:http://www.mydoc123.com/p-1067961.html