UL 2353-2012 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire (Second Edition Reprint with Revisions Through and Including July 20 2015)《单层和多层绝缘绕组线》.pdf
《UL 2353-2012 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire (Second Edition Reprint with Revisions Through and Including July 20 2015)《单层和多层绝缘绕组线》.pdf》由会员分享,可在线阅读,更多相关《UL 2353-2012 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire (Second Edition Reprint with Revisions Through and Including July 20 2015)《单层和多层绝缘绕组线》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2353 Single- and Multi-Layer Insulated Winding WireUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHO
2、RIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Single- and Multi-Layer Insulated Winding Wire, UL 2353 Second Edition, Dated May 14, 2012 Summary of Topics This revision of ANSI/UL 2353 includes the following changes: Downgrade of the testing vol
3、tage of the Spark Test in Section 14 Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the
4、date of publication or the date on which the changed requirement becomes effective. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated April 19, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system
5、, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability o
6、r tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL re
7、presentative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harm
8、less from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effe
9、ct, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Stand
10、ard, and are preceded by a SUPERSEDED REQUIREMENTS notice. SEPTEMBER 5, 2013 UL 2353 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 5, 2013 UL 2353 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR
11、ODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 14, 2012 (Title Page Reprinted: September 5, 2013) 1 UL 2353 Standard for Safety for Single- and Multi-Layer Insulated Winding Wire First Edition July, 2004 Second Edition May 14, 2012 This ANSI/UL Standard for Safety consists of the Second Edi
12、tion including revisions through September 5, 2013. The most recent designation of ANSI/UL 2353 as an American National Standard (ANSI) occurred on September 3, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments
13、or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic
14、 copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 2353-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU
15、RTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 14, 2012 SINGLE- AND MULTI-LAYER INSULATED WINDING WIRE - UL 2353 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Gene
16、ral 4 2.1 Units of measurement .4 2.2 Undated references .5 3 Glossary .5 CONSTRUCTION 4 Conductor Dimensions .6 5 Number of Layers .8 6 Thickness of Insulation 9 PERFORMANCE 7 General .11 8 Electric Strength Test Straight Sample 11 9 Electrical Strength Test Twisted Sample 12 10 Flexibility and Adh
17、erence Test 14 11 Retention of Electric Strength After Bending Test .15 12 Heat Shock Test 16 13 Infrared Analysis Test .17 MANUFACTURING AND PRODUCTION TESTS 14 Spark Test .17 15 Sampling Test 18 MARKINGS 16 Details .18 MAY 14, 2012 SINGLE- AND MULTI-LAYER INSULATED WINDING WIRE - UL 2353 3UL COPYR
18、IGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This Standard contains requirements for winding wire used in transformers without interleaved insulation; and solid insulation and insulated winding wire without interleaved in
19、sulation intended for use in accordance with the following standards: a) Standard for Information Technology Equipment Safety Part 1: General Requirements, UL 60950-1; or the b) Standard for Medical Electrical Equipment, Part 1: General Requirements for Safety, UL 60601-1. c) Safety of power transfo
20、rmers, power supplies, reactors and similar products Part 1: General requirements and tests, IEC 61558-1. These requirements are not intended to prohibit use of this type of winding wire in equipment covered by the scope of other Standards when these requirements are determined to be compatible with
21、 those Standards. 1.1 revised May 14, 2012 1.2 These requirements cover winding wires with a diameter between 0.05 mm (0.002 inch) and 5.0 mm (0.2 inch). 1.3 The winding wire covered by this Standard shall also comply with the infrared analysis requirements in the Standard for Polymeric Materials Sh
22、ort Term Property Evaluations, UL 746A. 1.4 This Standard does not cover solvent-based enamel coated magnet wire. See the Standard for Systems of Insulating Materials General, UL 1446. If the desired useage of the single- and multi-layer Insulated winding wire is above Class 105 (A), additional test
23、ing of the insulation system would be required in accordance with UL 1446. 2 General 2.1 Units of measurement 2.1.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. MAY 14, 2012 SINGLE- AND MULTI-LAYER INSULATED WINDING WIRE - U
24、L 2353 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Undated references 2.2.1 Any undated reference to a code or standard appearing in the requirements of this Standard shall be interpreted as referring to the latest edition of that c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL23532012ULSTANDARDFORSAFETYSINGLEANDMULTILAYERINSULATEDWINDINGWIRESECONDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJULY202015

链接地址:http://www.mydoc123.com/p-1067900.html