UL 2353 CRD-2015 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire - Section Paragraph Reference Subject Zero Defect Fully - Insulated Wire (FIW) (Edition 2 Ma.pdf
《UL 2353 CRD-2015 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire - Section Paragraph Reference Subject Zero Defect Fully - Insulated Wire (FIW) (Edition 2 Ma.pdf》由会员分享,可在线阅读,更多相关《UL 2353 CRD-2015 UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire - Section Paragraph Reference Subject Zero Defect Fully - Insulated Wire (FIW) (Edition 2 Ma.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): OBJT2Standard Number: UL 2353Standard Title: Standard for Single- and Multi-Layer Insulated Winding WireEdition Date: May 14, 2012Edition Number: 2Section /
3、Paragraph Reference:Subject: Zero Defect Fully Insulated Wire (FIW)DECISION:1.1 This Standard contains requirements for single and multi layer insulated winding wire used intransformers without interleaved insulation; and solid insulation and insulated winding wire withoutinterleaved insulation inte
4、nded for use in accordance with the following standards:a) Standard for Information Technology Equipment - Safety - Part 1: General Requirements, UL60950-1; or theb) Standard for Medical Electrical Equipment, Part 1: General Requirements for Safety, UL60601-1.c) Safety of power transformers, power s
5、upplies, reactors and similar products - Part 1:General requirements and tests, IEC 61558-1.These requirements are not intended to prohibit use of this type of winding wire in equipment covered bythe scope of other Standards when these requirements are determined to be compatible with thoseStandards
6、.1.1A This standard also contains requirements for enamelled Fully-Insulated Wire (FIW) that are deemedsuitable for use in end-products standards. The enamelled winding wire shall be a Recognized MagnetWire (OBMW2) designated ANSI/NEMA Type MW85.1.2 These requirements cover winding wires with a diam
7、eter between 0.05 mm (0.002 inch) and 5.0 mm(0.2 inch) and MW85 solvent-based enamel coated winding wires with a diameter between 0.040 mm and1.60 mm. that comply with Specifications for particular types of winding wires - Part 56: Solderable fullyinsulated (FIW) zero-defect polyurethane enamelled r
8、ound copper wire with nominal conductor diameter0,040 mm to 1,600 mm, class 180, IEC 60317-56.1.4 This Standard does not cover solvent-based enamel coated magnet wire. See the Standard forSystems of Insulating Materials - General, UL 1446. If the desired useage of the single- and multi-layerInsulate
9、d winding wire is above Class 105 (A), additional testing of the insulation system would berequired in accordance with UL 1446.Exception: As noted in Clause 1.1A.3.4.1 INSULATING LAYER - A single, concentric thickness of material that is detectable with an optical ormechanical measuring device. Enam
10、el, bond coats, etc. are not considered insulating layers.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULException: As noted in Clause 1.1A.4 Conductor DimensionsSingle and Multi Layer Insulated Wire :4.1 When determining the conductor dimens
11、ions, tin or any other metal on the conductor is allowed toremain on the conductor and included in the measurement. Solvent based enamels are to be removedprior to any measurements. Measurements of the diameter of a solid conductor are to be made over suchcoating by means of a machinists micrometer
12、caliper having flat surfaces both on the anvil and on theend of the spindle and calibrated to read directly to at least 0.001 inch or 0.01 mm, with each division ofa width that facilitates estimation of each measurement to 0.0001 inch or 0.001 mm. The maximum andminimum diameters at a given point on
13、 the conductor are each to be recorded to the nearest 0.0001 inchor 0.001 mm, added together, and divided by 2 without any rounding of the sum or resulting average.Fully Insulated Wire (FIW) :4.4 When determining the conductor dimensions solvent based enamels are to be removed prior to anymeasuremen
14、ts. Measurements of the diameter of a solid conductor are to be made by means of amachinists micrometer caliper having flat surfaces both on the anvil and on the end of the spindle andcalibrated to read directly to at least 0.001 inch or 0.01 mm, with each division of a width that facilitatesestimat
15、ion of each measurement to 0.0001 inch or 0.001 mm. The maximum and minimum diameters ata given point on the conductor are each to be recorded to the nearest 0.0001 inch or 0.001 mm, addedtogether, and divided by 2 without any rounding of the sum or resulting average.5 Number of LayersSingle and Mul
16、ti Layer Insulated Wire :5.1 Transformer winding wire with extruded or spirally wrapped insulation where the layers can beindividually tested for electric strength shall comply with one of the following constructional requirements:a) Basic insulation consisting of at least one layer of material, whi
17、ch complies with the ElectricStrength Test - Straight Sample, Section 8, for basic insulation;b) Supplementary insulation consisting of at least two layers of material, each of whichcomplies with the Electric Strength Test - Straight Sample, Section 8, for supplementaryinsulation;c) Supplementary in
18、sulation consisting of three layers of material for which all combinations ofthe two layers together complies with the Electric Strength Test - Straight Sample, Section 8, forsupplementary insulation;d) Reinforced insulation, intended for use in Information Technology equipment, consisting of atleas
19、t two layers of material, each of which complies with the Electric Strength Test - StraightSample, Section 8, for reinforced insulation; ore) Reinforced insulation consisting of three layers of materials for which all combinations of twolayers together complies with the Electric Strength Test - Stra
20、ight Sample, Section 8, forreinforced insulation.5.6 Solvent based enamel insulation used to coat the conductor is not to be counted as a layer whendetermining Basic, Supplementary and Reinforced insulation.STANDARD NUMBER: UL 2353 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O
21、RDISTRIBUTION WITHOUT PERMISSION FROM ULException: Solvent based enamel insulation used to coat the conductor shall be counted as a layer, if it:a) Complies with the Specifications for particular types of winding wires - Part 56: Solderablefully insulated (FIW) zerodefect polyurethane enamelled roun
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2353CRD2015ULSTANDARDFORSAFETYSINGLEANDMULTILAYERINSULATEDWINDINGWIRESECTIONPARAGRAPHREFERENCESUBJECTZERODEFECTFULLYINSULATEDWIREFIWEDITION2MAPDF

链接地址:http://www.mydoc123.com/p-1067899.html