《UL 1703 CRD-2015 UL Standard for Safety Flat-Plate Photovoltaic Modules and Panels - Section Paragraph Reference 31 2 1 2 Subject (Edition 3 March 15 2002)《平板光伏组件和板的UL安全标准 节 段落参考 .pdf》由会员分享,可在线阅读,更多相关《UL 1703 CRD-2015 UL Standard for Safety Flat-Plate Photovoltaic Modules and Panels - Section Paragraph Reference 31 2 1 2 Subject (Edition 3 March 15 2002)《平板光伏组件和板的UL安全标准 节 段落参考 .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): QIIAStandard Number: UL 1703Standard Title: Standard for Flat-Plate Photovoltaic Modules and PanelsEdition Date: March 15, 2002Edition Number: 3Section / Par
3、agraph Reference: 31.2.1.2Subject:DECISION:31.2.1.2 A fire rated module or panel intended for stand-off or rack mounting in combination with roofcoverings shall be installed as shown in this Section and according the manufacturers installationinstructions for both the module and mounting system with
4、 respect to the fire performance requirementsfor Class A, B, or C when the module or panel is marked as being fire rated as specified in 47.11. Forinstallations that are wider than the 40 inch (1016 mm) standard test deck, supports may need to befabricated on which to mount the mounting system. Any
5、support system is to be developed to ensureconsistency with installation instructions and field conditions. The mounting system with installed PVmodule(s) or panel(s) shall be centered on the test deck and extend to the edges of the test deck. Themounted modules or panels shall be tested in combinat
6、ion with the following roof constructions:Steep-Sloped Systems - Spread of Flame: When designed for steep-sloped roofs for slopes greaterthan or equal to 2 in/ft (167 mm/m), a module or panel intended for stand-off or rack mounting incombination with a roof covering shall be tested in combination wi
7、th the following roof construction:a) Roofing substrate: 15/32 inch (12 mm) thick plywood;b) Underlayment: ASTM D226 Type 1 Roofing Underlayment (also known as 15 lb RoofingFelt); andc) Roof Covering: Listed Class A 3 tab asphalt shingle, ASTM D3462, Standard Specificationsfor Asphalt Shingles Made
8、from Glass Felt and Surfaced with Mineral Granules. As analternate roof construction it is permitted to use any Classified rolled asphalt membranemechanically secured over a noncombustible substrate.The roof covering system must demonstrate a flame extension of at least 48 inches (1219 mm) and notmo
9、re than 72 inches (1829 mm) in the average of three baseline tests.As an alternate to determining baseline results using the adjustment of flame temperature, it shallbe permitted to adjust gas flows consistent with the running average of gas flows from previoussuccessful baseline tests, in order to
10、attain the prescribed flame extension. The gas and air flowvalues determined from the baseline set of tests shall be used during the actual Spread of Flametests.Low-Sloped Mounting Systems - Spread of Flame: When designed for low-sloped roofs for slopes lessthan 2 in/ft (167 mm/m), a module or panel
11、 intended for stand-off or rack mounting in combination with aroof covering shall be tested in combination with the following roof construction:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULa) Roofing substrate: 15/32 inch (12 mm) thick plyw
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1703CRD2015ULSTANDARDFORSAFETYFLATPLATEPHOTOVOLTAICMODULESANDPANELSSECTIONPARAGRAPHREFERENCE31212SUBJECTEDITION3MARCH152002

链接地址:http://www.mydoc123.com/p-1067638.html