UL 1703 CRD-2010 UL Standard for Safety Flat-Plate Photovoltaic Modules and Panels - Section Paragraph Reference 41 1 Subject Mechanical Loading Test Deflection Parameter (Edition.pdf
《UL 1703 CRD-2010 UL Standard for Safety Flat-Plate Photovoltaic Modules and Panels - Section Paragraph Reference 41 1 Subject Mechanical Loading Test Deflection Parameter (Edition.pdf》由会员分享,可在线阅读,更多相关《UL 1703 CRD-2010 UL Standard for Safety Flat-Plate Photovoltaic Modules and Panels - Section Paragraph Reference 41 1 Subject Mechanical Loading Test Deflection Parameter (Edition.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): QIGUStandard Number: UL 1703Edition Date: March 15, 2002Edition Number: 3Section / Paragraph Reference: 41.1Subject: Mechanical Loading Test Deflection Param
3、eterDECISION:Paragraph 41.1 to be revised as follows:A module or panel and any mounting hardware supplied with the module or panel shall withstand a loadas shown in Figure 41.1 and specified in 41.2 for a period of 30 min, without evidence of structural ormechanical failure. Modules that are intende
4、d to be installed as part of a building wall or roof structure,and serve as primary members of that building wall or roof structure, shall not have a deflection of morethan L/240; where L is equal to the clear span length in feet of the deflected member. All glazingmaterials shall be of such strengt
5、h as to withstand the loads specified in 41.2.Exception: Modules that are intended to be installed as part of a building wall or roof structure only inapplications where they do not serve as a member of the building primary structural frame shall besubjected to the Mechanical Loading Test based on 1
6、00% and 150% of the manufacturers rated load andcomply with 41.3. Lateral (center of glass) deflections under the 100% load shall be measured andreported in the instruction manual.Paragraph 41.3 to be added as follows:41.3 Upon completion of the Mechanical Loading Test as described in 41.1 and 41.2
7、for modules that areintended to be installed as part of a building wall or roof structure only in applications where they do notserve as a member of the building primary structural frame, a repeat of the Voltage, Current and PowerMeasurements Test is to be conducted as described in Section 20. Value
8、s of the initial voltage, currentand power shall not differ from the measured values in the repeated test to the degree that there isevidence of internal damage to the module as a result of the loading.Paragraph 48.7 to be added as follows:48.7 The Installation Instructions for modules that are inte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1703CRD2010ULSTANDARDFORSAFETYFLATPLATEPHOTOVOLTAICMODULESANDPANELSSECTIONPARAGRAPHREFERENCE411SUBJECTMECHANICALLOADINGTESTDEFLECTIONPARAMETEREDITIONPDF

链接地址:http://www.mydoc123.com/p-1067637.html