UL 1699B-2018 UL Standard for safety Photovoltaic (PV) DC Arc-Fault Circuit Protection (First Edition).pdf
《UL 1699B-2018 UL Standard for safety Photovoltaic (PV) DC Arc-Fault Circuit Protection (First Edition).pdf》由会员分享,可在线阅读,更多相关《UL 1699B-2018 UL Standard for safety Photovoltaic (PV) DC Arc-Fault Circuit Protection (First Edition).pdf(91页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1699B Photovoltaic (PV) DC Arc-Fault Circuit Protection STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRI
2、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Photovoltaic (PV) DC Arc-Fault Circuit Protection, UL 1699B First Edition, Dated August 22, 2018 SUMMARY OF TOPICS This is the rst edition of ANSI/UL 1699B, Standard for Photo
3、voltaic (PV) DC Arc-Fault Circuit Protection. The new requirements are substantially in accordance with Proposal(s) on this subject dated January 5, 2018 and June 15, 2018. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by
4、 any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no
5、event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised o
6、f the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss,
7、 expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 22, 2018 UL 1699B tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
8、EPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 22, 2018 UL 1699B tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 22, 2018 1 UL 1699B Standard for Photovoltaic (PV) DC Arc-Fault Circuit Protection
9、 First Edition August 22, 2018 This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 1699B as an American National Standard (ANSI) occurred on August 10, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title
10、Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printe
11、d nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 1699-2018UL COPYRIGHTED MATERIAL NOT A
12、UTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 22, 2018 PHOTOVOLTAIC (PV) DC ARC-FAULT CIRCUIT PROTECTION - UL 1699B 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS PART 1
13、ALL DEVICES INTRODUCTION 1 Scope .7 2 Glossary .7 3 Components9 4 Units of Measurement 9 5 Undated References .10 CONSTRUCTION 6 General.10 7 Corrosion Protection .10 8 Current Carrying Parts10 9 Internal Wiring .10 10 Insulation 10 11 Power Supply 10 12 Operating Mechanism .11 13 Programmable Circu
14、it Components .11 14 Electronic Interruption .12 14.1 General .12 14.2 Off state or stand-by mode current12 14.3 Reliability13 14.4 Programmable circuit components13 MANUFACTURING AND PRODUCTION LINE TESTS 15 General13 P A R T2P VAFCI, PV AFD, AND PV ID DEVICES CONSTRUCTION 16 General13 17 Accessibi
15、lity of Energized Parts 14 18 Spacings 16 19 Terminals 17 19.1 General .17 19.2 Terminal leads .17 19.3 Wire binding screw terminals 18 19.4 Pressure wire terminals .18 20 Enclosure 19 21 Grounding .19 22 Annunciator 19 23 Test Circuits .19 PERFORMANCE AUGUST 22, 2018 PHOTOVOLTAIC (PV) DC ARC-FAULT
16、CIRCUIT PROTECTION - UL 1699B 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 24 General20 25 Humidity Conditioning .21 26 Leakage Current Measurement .22 27 Voltage Surge Test .24 27.1 General .24 27.2 Unwanted tripping test (Ring wave).25
17、 27.3 Surge immunity test (Combination wave) 25 28 Environmental Test Sequence27 29 Arc Fault Detection Tests 28 29.1 General .28 29.2 One string, one MPPT .39 29.3 Two strings combined, one MPPT 41 29.4 Combiner box43 29.5 External AFCI45 29.6 DC-DC converter systems .45 29.7 Microinverters47 30 Un
18、wanted Tripping Tests 50 30.1 General .50 30.2 Loading condition I Inverters, converters, and charge controllers .50 30.3 Loading condition II DC switch operation 55 30.4 Loading condition III Irradiance step changes 56 31 Normal Temperature Test .57 32 Overvoltage Test .58 33 Overload Test 59 34 En
19、durance Test 59 35 Dielectric Voltage-Withstand Test .60 36 Abnormal Operations Test .61 37 Short Circuit Current Test62 38 Corrosion Test .63 39 Surge Current Test .63 39.1 General .63 39.2 Mounting and installation 64 39.3 Surge parameters 64 39.4 Surge polarity 64 40 Abnormal Overvoltage Tests .6
20、4 40.1 General .64 40.2 Full phase voltage high current abnormal overvoltage test .65 40.3 Limited current abnormal overvoltage test .67 41 Supplemental Voltage Surge Immunity Test68 41.1 General .68 41.2 Surge immunity test (combination wave) 69 42 Resistance to Environmental Noise Test 70 42.1 Gen
21、eral .70 42.2 Electrostatic discharge immunity .71 42.3 Radiated electromagnetic eld immunity 71 42.4 Electrical fast transient immunity .71 42.5 Voltage surge immunity .71 42.6 Immunity to conducted disturbances, induced by RF elds 72 42.7 Voltage dips, short interruptions and voltage variations im
22、munity .72 43 Strain-Relief Tests 72 43.1 Terminal lead strain-relief test72 43.2 Power-supply cord strain-relief test .73 44 Mechanical Tests .73 AUGUST 22, 2018 PHOTOVOLTAIC (PV) DC ARC-FAULT CIRCUIT PROTECTION - UL 1699B 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU
23、TION WITHOUT PERMISSION FROM UL 45 Dust Test 73 RATINGS 46 General74 MARKINGS 47 General75 INSTRUCTIONS 48 Operating and Installation Instructions .76 PART 3 INVERTERS, CONVERTERS, AND CHARGE CONTROLLERS WITH INTEGRAL PHOTOVOLTAIC DC ARC-FAULT CIRCUIT INTERRUPTER PROTECTION GENERAL 49 General77 CONS
24、TRUCTION 50 General77 51 Alternate Spacings Clearances and Creepage Distances 77 52 Annunciator 78 53 Test Circuits .78 PERFORMANCE 54 General79 55 Voltage Surge Test .80 56 Overvoltage, Overload, Endurance, Abnormal Operations, and Short Circuit Tests80 MARKINGS 57 General81 INSTRUCTIONS 58 Operati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1699B2018ULSTANDARDFORSAFETYPHOTOVOLTAICPVDCARCFAULTCIRCUITPROTECTIONFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-1067634.html