UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf
《UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf》由会员分享,可在线阅读,更多相关《UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf(120页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1699 Arc-Fault Circuit-InterruptersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE
2、R REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Arc-Fault Circuit-Interrupters, UL 1699 Second Edition, Dated April 7, 2006 SUMMARY OF TOPICS This revision of ANSI/UL 1699 includes a Clarication of Requirements for Programmable Components. Text that has been chan
3、ged in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed require
4、ment becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated August 16, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical p
5、hotocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any spec
6、ial, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In
7、 no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim,
8、or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or ot
9、her elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. NOVEMBER
10、 8, 2013 UL 1699 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 UL 1699 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 7, 2006 (Ti
11、tle Page Reprinted: November 8, 2013) 1 UL 1699 Standard for Arc-Fault Circuit-Interrupters First Edition February, 1999 Second Edition April 7, 2006 This ANSI/UL Standard for Safety consists of the Second Edition including revisions through November 8, 2013. The most recent designation of ANSI/UL 1
12、699 as an American National Standard (ANSI) occurred on November 5, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Pr
13、oposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ow
14、nerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 1699-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 ARC-FAULT CIRC
15、UIT-INTERRUPTERS - UL 1699 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Glossary .8 3 Components 9 4 Units of Measurement 10 5 Undated References .10 CONSTRUCTION ALL DEVICES 6 Gene
16、ral .10 7 Accessibility of Energized Parts 10 8 Corrosion Protection .12 9 Current Carrying Parts 12 10 Internal Wiring 12 11 Insulation 12 12 Spacings 12 13 Operating Mechanism .14 14 Programmable Components .14 15 Test Circuit 15 BRANCH/FEEDER ARC-FAULT CIRCUIT-INTERRUPTER 16 General 16 17 Termina
17、ls 16 17.1 General .16 17.2 Terminal leads .16 17.3 Wire binding screw terminals 16 17.4 Pressure wire terminals .17 18 Enclosure 17 19 Grounding .17 OUTLET CIRCUIT ARC-FAULT CIRCUIT-INTERRUPTER 20 General 17 21 Terminals 18 22 Housings 18 23 Grounding .18 PORTABLE ARC-FAULT CIRCUIT-INTERRUPTER 24 G
18、eneral 18 25 Plugs/Receptacles 18 26 Cords .19 27 Direct Plug-In 19 28 Grounding .23 29 Enclosures .23 NOVEMBER 8, 2013 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CORD ARC-FAULT CIRCUIT-INTERRUP
19、TERS 30 General 23 31 Plugs/Receptacles 23 32 Grounding .23 33 Enclosures .24 PERFORMANCE 34 General 24 35 Drop and Impact Tests 26 35.1 General .26 35.2 Impact test .26A 35.3 Drop test 27 36 Humidity Conditioning .27 37 Leakage Current Measurement .27 38 Voltage Surge Test .29 38.1 General .29 38.2
20、 Unwanted tripping test (Ring wave) .29 38.3 Surge immunity test (Combination wave) 32 39 Environmental Test Sequence 33 40 Arc Fault Detection Tests 34 40.1 General .34 40.2 Carbonized path arc ignition test .34 40.3 Carbonized path arc interruption test .38 40.4 Carbonized path arc clearing time t
21、est 40 40.5 Point contact arc test .42 41 Unwanted Tripping Tests 43 41.1 General .43 41.2 Loading condition I inrush current 43 41.3 Loading condition II normal operation arcing .43 41.4 Loading condition III non-sinusoidal waveform .44 41.5 Loading condition IV cross talk .45 41.6 Loading conditio
22、n V multiple load .45 41.7 Loading condition VI lamp burnout 45 42 Operation Inhibition Tests 46 42.1 General .46 42.2 Masking the signal to operate 51 42.3 EMI lter 53 42.4 Line impedance 55 43 Dielectric Voltage-Withstand Test .57 44 Resistance to Environmental Noise Test .57 44.1 General .57 44.2
23、 Electrostatic discharge immunity .58 44.3 Radiated electromagnetic eld immunity 58 44.4 Electrical fast transient immunity .58 44.5 Voltage surge 59 44.6 Immunity to conducted disturbances, induced by RF elds 59 44.7 Voltage dips, short interruptions and voltage variations immunity .59 45 Normal Te
24、mperature Test 60 46 Overvoltage Test .61 47 Overload .61 48 Endurance Test 62 AUGUST 29, 2008 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 49 Abnormal Operations Test .63 50 Surge Current Test .6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL16992006ULSTANDARDFORSAFETYARCFAULTCIRCUITINTERRUPTERSSECONDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGNOVEMBER082013