《UL 1598 CRD-2018 UL Standard for Safety Luminaires - Section Paragraph Reference Revised Table 20 1 1 Revised 20 5 New 20 5 2 Subject Alternate Method for Providing Installation I.pdf》由会员分享,可在线阅读,更多相关《UL 1598 CRD-2018 UL Standard for Safety Luminaires - Section Paragraph Reference Revised Table 20 1 1 Revised 20 5 New 20 5 2 Subject Alternate Method for Providing Installation I.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): VariousStandard Number: UL 1598Standard Title: Standard for LuminairesEdition Date: September 17, 2008Edition Number: 3Section / Paragraph Reference: Annex GSubject: Revised Annex G addressing LED lum
3、inaires with Edison screwlampholdersDECISION:Annex G (normative)Luminaires for use with self-ballasted compact fluorescent (CFL) or self-ballasted light emittingdiode (LED) lampsG.1 Special terminologyThe following definitions apply:Lampholder, Conventional Any lampholder defined in or referenced by
4、 ANSI C81.62 except theGU-24 and any designation reserved for use by LED lamps only.Lampholder, Edison (Screw) Refer to ANSI C81.62. These designations use an “E” prefix (i.e.: E12,E26, etc.).Self-Ballasted Lamp Self-Ballasted Lamp, either self-ballasted compact fluorescent lamp orself-ballasted LED
5、 lamp.Self-Ballasted Compact Fluorescent Lamp (CFL) A device provided with a lamp base andincorporating a non-replaceable fluorescent light source and any additional elements necessary forstarting and stabilizing operation of the light source, which cannot be dismantled without beingpermanently dama
6、ged.Self Ballasted Light Emitting Diode (LED) Lamp A device provided with a lamp base andincorporating a non-replaceable LED light source and any additional elements necessary for starting andstabilizing operation of the light source, which cannot be dismantled without being permanently damaged.G.2
7、GeneralG.2.1 These criteria apply to luminaires with any ANSI type screwbase or pinbase lampholder such aswith GU24, candelabra (E120), intermediate (E17), medium (E26), mogul (E39), designed for use with aself-ballasted lamp.G.3 Construction, Test and Marking RequirementsUL COPYRIGHTED MATERIAL NOT
8、 AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULG.3.1 Incandescent Luminaires having a with conventional lampholders ANSI screwbase orpinbase lampholders other than GU24G.3.1.1 Construction All construction requirements in this standard applicable to incandescentluminai
9、res construction requirements in this standard.G.3.1.2 Tests All test requirements in this standard applicable to incandescent luminaires testrequirements in this standard. Testing shall be conducted based on the incandescent lamp wattage on thelamp replacement marking or clause 19.8.7, whichever re
10、sults in a greater wattage.G.3.1.3 Markings All markings in this standard applicable to incandescent luminaires markings in thisstandard, plus markings relevant to self-ballasted lamp use. Self-ballasted markings shall include arelamping marking that specifies max wattage self-ballasted compact fluo
11、rescent (CFL) or self-ballastedLED lamp permitted or both and indicates compliance with the Standard for Self-Ballasted Lamps andLamp Adapters, UL 1993/NMX-J-578/1-ANCE/CSA C22.2 No. 1993. The specified wattage shall notexceed the maximum incandescent lamp wattage marked on the luminaire. The markin
12、g shall be in formS24-L1.G.3.2 Fluorescent luminaires having an ANSI with GU24 pinbase lampholdersG.3.2.1 Construction All construction requirements in this standard applicable to fluorescent luminairesconstruction requirements in this standard.G.3.2.2 Tests All test requirements in this standard ap
13、plicable to fluorescent luminaires testrequirements in this standard.G.3.2.3 Markings All markings in this standard applicable to fluorescent luminaires marking in thisstandard, plus markings relevant to self-ballasted lamp use. Self-ballasted markings shall include arelamping marking that specifies
14、 the max wattage self-ballasted compact fluorescent (CFL) orself-ballasted LED lamp permitted or both and indicates compliance with the Standard for Self-BallastedLamps and Lamp Adapters, UL 1993/NMX-J-578/1-ANCE/CSA C22.2 No. 1993. The marking shall be inform S24-L1.G3.3 LED luminaires with Edison
15、lampholdersNOTE: This clause covers luminaires with replacement lamp markings that only specify LED lamps, with no reference toincandescent or halogen lamps.G.3.3.1 Construction All construction requirements in this standard applicable to incandescentluminaires.G.3.3.2 Tests All test requirements in
16、 this standard applicable to incandescent luminaires, as modifiedby clause G3.3.3G.3.3.3 Test Lamps - In lieu of the requirements in 19.8, testing shall be conducted using the appropriate120 volt rated incandescent test lamps specified by Table G.3.3, with the supply source adjusted such thatthe tes
17、t lamps dissipate 10 2% more power (i.e.: wattage) than the highest input power rating for theLED lamps that are intended for the luminaire under test. Reflector test lamps shall be used only if theluminaire will be marked for use with such lamps exclusively.Example: For luminaires intended for use
18、with 15 Watt LED lamps, the incandescent test lamps should dissipate 16.5 0.3Watts during the temperature testSTANDARD NUMBER: UL 1598 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable G.3.3Incandescent Test LampsDesignation Type Test L
19、amps1E39 Reflector 300W BR402E39 300W PS352, 300W PS252E26 Reflector 65W BR40, 65W BR30, 50W R20, 40W R16E26 40W A19, 40W A15, 40W B10E17 40W T6.5, 40W S11, 40W S8E12 40W B10, 25W T6, 25W T82,7WC7E11 50W T431For each designation and type, test lamps are listed in order of preference. Use the test la
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1598CRD2018ULSTANDARDFORSAFETYLUMINAIRESSECTIONPARAGRAPHREFERENCEREVISEDTABLE2011REVISED205NEW2052SUBJECTALTERNATEMETHODFORPROVIDINGINSTALLATIONIPDF

链接地址:http://www.mydoc123.com/p-1067561.html