UL 10C-2016 UL Standard for Safety Positive Pressure Fire Tests of Door Assemblies (Third Edition).pdf
《UL 10C-2016 UL Standard for Safety Positive Pressure Fire Tests of Door Assemblies (Third Edition).pdf》由会员分享,可在线阅读,更多相关《UL 10C-2016 UL Standard for Safety Positive Pressure Fire Tests of Door Assemblies (Third Edition).pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 10C Positive Pressure Fire Tests of Door Assemblies STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTE
2、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Positive Pressure Fire Tests of Door Assemblies, UL 10C Third Edition, Dated June 9, 2016 Summary of Topics The Third Edition of the Standard for Safety for Positive Pressure Fire
3、 Tests of Door Assemblies, UL 10C, has been issued to reect the latest ANSI approval date, and to incorporate the proposal dated April 15, 2016. This proposal includes the following: Oxygen percentage readings. The new requirements are substantially in accordance with Proposal(s) on this subject dat
4、ed April 15, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty
5、of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or a
6、ny other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of t
7、he claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is
8、storing an electronic Standard on the purchasers computer system. JUNE 9, 2016 UL 10C tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 9, 2016 UL 10C tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCT
9、ION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 9, 2016 1 UL 10C Standard for Positive Pressure Fire Tests of Door Assemblies Prior to the rst edition, the requirements for the products covered by this standard were included in the Standard for Fire Tests of Door Assemblies, UL 10B. First Editio
10、n February, 1998 Second Edition January, 2009 Third Edition June 9, 2016 This ANSI/UL Standard for Safety consists of the Third Edition. The most recent designation of ANSI/UL 10C as an American National Standard (ANSI) occurred on June 9, 2016. ANSI approval for a standard does not include the Cove
11、r Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are
12、copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 10C
13、-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 9, 2016 POSITIVE PRESSURE FIRE TESTS OF DOOR ASSEMBLIES - UL 10C 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSI
14、ON FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 5 2.1 Units of measurement .5 2.2 Undated references .5 CONTROL OF FIRE TESTS 3 Furnace Construction 5 3.1 Furnace size .5 3.2 Furnace construction materials .5 3.3 Furnace burners 5 4 Time-Temperature Curve 6 4.1 General .6 4.2 Uniformity of tem
15、perature distribution .6 5 Furnace Temperatures 7 6 Unexposed Surface Temperatures and Cotton Pad Test .8 7 Furnace Pressure .9 TEST ASSEMBLIES 8 Construction and Size 12 9 Mounting for Test Purposes .12 CONDUCT OF TESTS 10 Supporting Construction .13 11 Fire Endurance Test 13 12 Hose Stream Test 13
16、 REPORT 13 General 14 CONDITIONS OF ACCEPTANCE 14 General 15 15 Specic 15 APPENDIX A A1 Standard Time-Temperature Curve for Control of Fire Tests .A1 APPENDIX B B1 Hose Stream Pattern .B1 JUNE 9, 2016 POSITIVE PRESSURE FIRE TESTS OF DOOR ASSEMBLIES - UL 10C 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FO
17、R FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These methods of re tests are applicable to swinging door assemblies, including door frames with lights and panels, of various materials and types of construction for use in wall openings to retard the passage
18、 of re. The method does not provide an evaluation of a swinging door assembly when that assembly is part of a larger assembly (e.g. sliding re door assembly), or when it is intended to be used as an elevator entrance. 1.2 Tests made in conformity with these test methods are intended to register perf
19、ormance during the test exposure; but such tests shall not be construed as determining suitability for use after exposure to re. 1.3 It is the intent that tests made in conformity with these test methods allow for the development of data to enable regulatory bodies to determine the suitability of do
20、or assemblies for use in locations where re resistance of a specied duration is required. 1.4 These methods are intended to evaluate the ability of a door assembly to remain in an opening during a predetermined test exposure. 1.5 The tests expose a specimen to a standard re exposure controlled to ac
21、hieve specied temperatures throughout a specied time period, followed by the application of a specied standard re hose stream. The exposure, however, is not representative of all re conditions, which vary with changes in the amount, nature, and distribution of re loading, ventilation, compartment si
22、ze and conguration, and heat sink characteristics of the compartment. It does, however, provide a relative measure of re performance of door assemblies under these specied re exposure conditions. 1.6 Any variation from the construction or conditions that are tested is capable of substantially changi
23、ng the performance characteristics of the assembly. 1.7 The methods do not provide the following: a) Full information as to performance of all door assemblies in walls constructed of materials other than those tested. b) Evaluation of the degree by which the door assembly contributes to the risk of
24、re by generation of smoke, toxic gases, or other products of combustion. c) A temperature limit on the unexposed side of the door assembly. d) A limit on the number of openings allowed in glazed areas or of the number and size of lateral openings between the door and frame. e) Measurement of the deg
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL10C2016ULSTANDARDFORSAFETYPOSITIVEPRESSUREFIRETESTSOFDOORASSEMBLIESTHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-1067331.html